ANÁLISE DA INFLUÊNCIA DA UMIDADE NO DESEMPENHO TÉRMICO DE TELHAS CERÂMICAS
Keywords:
Experimental test rig, roofs, heat fluxAbstract
The increase in energy consumption is one of the main concerns in the world today since the consumption to cool buildings' internal areas rises every year. Reducing thermal gain by using a roof is one of the best ways to decrease energy expenditures and provide thermal comfort to users of one-floored residential or commercial buildings. Thus, this work aims to analyze, by using an experimental bench, the influence of humidity on the thermal performance of porous and impermeable ceramic tile roofs as well as compare this results with the ones obtained with fiber-cement tiles. The humidity effect was analyzed through the adsorption of the water steam present in the air, the absorption of nocturnal condensation and through rainwater absorption. It was possible to verify that the adsorption of water steam and the absorption of nocturnal condensation show little influence on thermal gains, while rainwater absorption offered a higher reduction between porous and impermeable ceramic tiles. Such reduction reached 10%, throughout the 6 months of measurements. This study demonstrates that the use of porous ceramic tile roofs is much more effective to reduce thermal gains by the use of covers due to the rainwater evaporation process.