Insulated glass in Brazilian climates
relationship between energy savings, optical properties, and outdoor air temperature
DOI:
https://doi.org/10.46421/encacelacac.v18i1.7171Keywords:
facades, thermal performance, simulation, EnergyPlus, energy efficiencyAbstract
This article presents a study on the influence of insulated glass on energy consumption for cooling in an office building simulated for 410 Brazilian climate files. The evaluation was conducted using the EnergyPlus software, based on the typical floor model of a representative building and 18 specifications of solar control glass and their insulated versions. The data analysis was based on energy consumption for cooling. The results confirm that the greatest energy savings are initially achieved by reducing solar heat gain through the glass. The reduction of thermal transmittance in the insulated glass composition provides greater benefits in warmer climates, with an average temperature above 22°C, and for darker glass with higher energy absorption.
References
ABNT. NBR 16015 - Vidro insulado — Características, requisitos e métodos de ensaio. Rio de Janeiro: ABNT. 52 pág. 2012.
ABNT. NBR ISO 9050 - Vidros na construção civil — Determinação da transmissão de luz, transmissão direta solar, transmissão total de energia solar, transmissão ultravioleta e propriedades relacionadas ao vidro. Rio de Janeiro: ABNT. 28 pág. 2022.
ANDREIS, Cínthia. Influência de fachadas envidraçadas no consumo de energia de um edifício de escritórios em diferentes cidades brasileiras. 2014. Dissertação (Mestrado em Programa de Pós-Grad. em Arquitetura e Urbanismo) – Universidade Federal de Santa Catarina.
BUI V.P. et al. Evaluation of building glass performance metrics for the tropical climate. Energy and Buildings, Volume 157, Pages 195-203, 2017.
CEBRACE. Calumen. Disponível em: https://calumen.com. Acesso em 10 setembro 2023.
DUTTA, Arindam; SAMANTA, Akash. Reducing cooling load of buildings in the tropical climate through window glazing: A model to model comparison. Journal of Building Engineering. Volume 15, Pages 318-327, 2018.
ENERGYPLUS. Energyplus. 2023a. Disponível em: https://energyplus.net/. Acesso em: 12 novembro 2023.
ENERGYPLUS. Weather data by country – All regions – South America (WMO Region 3) – Brazil. 2023b. Disponível em https://energyplus.net/weather-region/south_america_
wmo_region_3/BRA. Acesso em: 10 março 2023.
FUNG, S. F., LU, L. Thermal performance analysis on different types of glazing of public rental housing in Hong Kong. Procedia Engineering, v. 205, p. 2832-2839, 2017.
GONZÁLEZ-JULIÁN, E., XAMÁN, J.; MORAGA, Nelson O.; CHÁVEZ, Y., ZAVALA-GUILLÉN, I., SIMÁ, E. Annual thermal evaluation of a double pane window using glazing available in the Mexican market. Applied Thermal Engineering. Volume 143,Pages 100-111, 2018.
KOH, Wee Shing et al. Evaluation of glazing retrofitting solution for the tropics. Energy and Buildings. v 223, 110190. 2020.
KRALJ, Aleš; DREV, Marija; ŽNIDARŠIČ, Matjaž; ČERNE, Boštjan; HAFNER, Jože; JELLE, Bjørn Petter. Investigations of 6-pane glazing: Properties and possibilities. Energy and Buildings. Volume 190, Pages 61-68, 2019.
LBNL - LAWRENCE BERKELEY NATIONAL LABORATORY. IGDB: international glazing database. Disponível em: < https://windows.lbl.gov/tools/IGDB/software-download>. Acesso em: 10/04/2022.
PINTO, Mônica Martins. Avaliação preditiva de conforto térmico em ambientes de escritórios climatizados próximos a fachadas com alto percentual de vidro. 2023. Tese (Doutorado em Programa de Pós-graduação em Arquitetura e Urbanismo) – Universidade Federal de Santa Catarina.
PINTO, Mônica Martins. Desempenho energético de edifícios de escritórios com vidros insulados em climas brasileiros. 2017. Dissertação (Mestrado em Programa de Pós-Grad. em Arquitetura e Urbanismo) – Universidade Federal de Santa Catarina.
SADOOGHI, Parham; KHERANI, Nazir P. Thermal analysis of triple and quad pane windows using partitioned radiant energy veils with varying physical and optical properties. Solar Energy, v. 174, p. 1163-1168, 2018.
SCHEIDT, F. S. S.; WESTPHAL, F. S. Edifícios de escritórios representativos para estudos de desempenho energético na cidade de Florianópolis. PARC Pesq. em Arquit. e Constr., Campinas, SP, v. 14, p. e023012, 2023.
SOMASUNDARAM, Sivanand; CHONG, Alex; WEI, Zhang; THANGAVELU, Sundar Raj. Energy saving potential of low-e coating based retrofit double glazing for tropical climate. Energy and Buildings. Volume 206, 109570, 2020.
WESTPHAL, Fernando Simon. Vidro plano para edificações. São Paulo: Oficina de Textos. 2022. ISBN: 978-65-86235-77-7