Thermal Exposure in Public School Classrooms: EnergyPlus Simulation and Cognitive Risk Ranges

Authors

  • Ana Carla Lara Nobre Universidade Estadual de Campinas
  • Lucila Chebel Labaki Universidade Estadual de Campinas

DOI:

https://doi.org/10.46421/entac.v21i1.8690

Keywords:

Thermal comfort, School infrastructure, Cognitive performance, Simulation

Abstract

The infrastructure of Brazilian public schools often leads to thermal discomfort, which the literature associates with reduced cognitive performance. This study analyzes thermal exposure during the school period in three classrooms of a public state school in Igarapava–SP, using EnergyPlus simulations to evaluate the concentration of operative temperatures within ranges associated with performance impairment. A total of 2,549 occupied hours were analyzed and classified according to reference ranges based on a proxy model derived from meta-analysis. The results indicate a predominance of temperatures above 26 °C, with a significant proportion exceeding 30 °C in all classrooms. The similarity between environments with different orientations and floor levels suggests a structural pattern of overheating, reinforcing the need to incorporate thermal exposure metrics and their impacts on learning into the assessment of naturally ventilated school buildings.

Author Biographies

  • Ana Carla Lara Nobre, Universidade Estadual de Campinas

    Mestranda em Arquitetura, Tecnologia e Cidade pela Universidade Estadual de Campinas.

  • Lucila Chebel Labaki, Universidade Estadual de Campinas

     Professora colaboradora da Universidade Estadual de Campinas 

References

AKESAKA, M.; SHIGEOKA, H. Hotter days, wider gap: the distributional impact of heat on student achievement. Social Science Research Network (SSRN), 2025. DOI: 10.2139/ssrn.5585199.

ASHRAE. ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy. Atlanta: American Society of Heating, Refrigerating and Air-Conditioning Engineers, 2020.

BARBIC, F. et al. Effects of different classroom temperatures on cardiac autonomic control and cognitive performances in undergraduate students. Physiological Measurement, v. 40, n. 3, 2019. DOI: 10.1088/1361-6579/ab1816.

BARBIC, F. et al. Effects of a cool classroom microclimate on cardiac autonomic control and cognitive performances in undergraduate students. Science of the Total Environment, v. 808, 2022. DOI: 10.1016/j.scitotenv.2021.152005.

CORREIA, Camila Machado de Azevedo; AMORIM, Cláudia Naves David; SANTAMOURIS, Mattheos. Use of passive cooling techniques and super cool materials to minimize cooling energy and improve thermal comfort in Brazilian schools. Energy and Buildings, v. 114125, 2024. DOI: 10.1016/j.enbuild.2024.114125.

LAMENHA, Melyna de Almeida. A escola técnica do programa Brasil profissionalizado: um projeto padrão para diferentes zonas bioclimáticas? 2016. Dissertação (Mestrado) – [Universidade Federal de Alagoas], 2016.

PARK, J. Heat stress and human capital production. Working Paper. Cambridge: Harvard University, 2016.

PORRAS-SALAZAR, J. A.; WYON, D.; PIDERIT-MORENO, B.; CONTRERAS-ESPINOZA, S.; WARGOCKI, P. Reducing classroom temperature in a tropical climate improved the thermal comfort and the performance of elementary school pupils. Indoor Air, v. 28, n. 6, p. 892–904, 2018. DOI: 10.1111/ina.12501.

ROACH, T.; WHITNEY, J. M. Heat and learning in elementary and middle school. Education Economics, v. 29, n. 5, p. 537–552, 2021. DOI: 10.1080/09645292.2021.1931815.

VASCONCELOS, D.; SILVA, S. de F.; BATISTA, J.; CAVALCANTI, F. Conforto Térmico em escolas públicas. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 20., 2024. Anais... 2024. DOI: 10.46421/entac.v20i1.6263.

WARGOCKI, P.; PORRAS-SALAZAR, J. A.; CONTRERAS-ESPINOZA, S. The relationship between classroom temperature and children's performance in school. Building and Environment, v. 157, p. 197–207, 2019. DOI: 10.1016/j.buildenv.2019.04.046.

WARGOCKI, P.; PORRAS-SALAZAR, J. A.; CONTRERAS-ESPINOZA, S.; BAHNFLETH, W. The relationships between classroom air quality and children's performance in school. Building and Environment, v. 173, 2020. DOI: 10.1016/j.buildenv.2020.106749.

WARGOCKI, P.; WYON, D. The effects of moderately raised classroom temperatures and classroom ventilation rate on the performance of schoolwork by children. HVAC&R Research, v. 13, n. 2, p. 193–220, 2007. DOI: 10.1080/10789669.2007.10390951.

Published

2026-08-20

Issue

Section

Conforto Ambiental e Eficiência Energética

How to Cite

NOBRE, A. C. L.; LABAKI, L. C. Thermal Exposure in Public School Classrooms: EnergyPlus Simulation and Cognitive Risk Ranges . NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, v. 21, n. 1, 20 Aug.2026.

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)