Evaluation of the thickness of asphalt waterproofing membranes using an optical measurement system
DOI:
https://doi.org/10.46421/entac.v21i1.9002Keywords:
Mantas asfálticas, mantas asfálticas para impermeabilização, sistemas de impermeabilização, estanqueidade, espessuraAbstract
Errors in waterproofing systems in buildings can be related to poorly qualified labor, absence or poor quality of designs, inadequate construction workflow, inappropriate or insufficient quality materials, insufficient supervision or monitoring, among others. This combination of factors compromises the watertightness, healthiness, performance, durability, and value of buildings. Therefore, to map sources of errors in waterproofing systems, the objective is to evaluate the thickness of asphalt membranes used in waterproofing systems using an optical measurement system. Membranes of 3 and 4 mm thickness from different manufacturers were evaluated. The results indicated asphalt membrane thicknesses ranging from 2.9 to 3.1 mm for 3.0 mm membranes and from 3.8 to 4.0 mm for 4.0 mm membranes. In conclusion, it is clear that the membranes met the normative requirement for a thickness deviation of ± 5% (NBR 9952, 2024). This paper contributes to increased reliability in waterproofing manufacturers and products, and to the mapping/diagnosis of error sources in waterproofing systems in civil construction.