Indoor daylighting performance based on the use of sheds
DOI:
https://doi.org/10.46421/entac.v21i1.8456Keywords:
Daylighting, Zenithal opening, Luminous performance, Shed, Two-sided shedAbstract
Zenithal openings can ensure better daylighting use in the environment when compared to windows. This research’s objective is to investigate the luminous performance of a classroom using zenithal openings in the city of Vitoria-ES. The methodology includes computer simulations using the software TropLux, with measurements taken from 7:00AM to 5:00PM, all days of the year, Dynamic Sky (DLD) of Vitoria-ES. The models are lateral opening (AL1); one- sided 20° (AZ1), 30° (AZ2), 40° (AZ3), 50° (AZ4), 60° (AZ5) inclined zenithal opening; two-sided 20° (AZ6), 30° (AZ7), 40° (AZ8), 50° (AZ9), 60° (AZ10) inclined zenithal opening. The analysis metrics are: Useful Daylighting Illuminance (UDI), Daylighting Autonomy (DA), Spatial Daylight Autonomy (SDA) and Average Monthly Illuminance. It was observed that, in both single and double-sided zenithal opening models, the best performance was achieved with the lowest inclination models, with performance decreasing as the inclination increases.
References
[1] FIGUEIREDO, Erika Ciconelli de. Abordagem do ritmo circadiano no projeto de iluminação natural em edifícios de escritórios. Revista Sítio Novo, Palmas, v. 7, p. 83–98, 2022.
[2] MATOS, Jéssica Cristine da Silva Fonseca; SCARAZZATO, Paulo Sergio. A iluminação natural no projeto de arquitetura: revisão sistemática da literatura. PARC: Pesquisa em Arquitetura e Construção, Campinas, SP, v. 8, n. 4, p. 249–256, 2017.
[3] LIU, Xin et al. Illumination distribution and daylight glare evaluation within different windows for comfortable lighting. Results in Optics, v. 3, p. 100080, 2021.
[4] MAPELLI, YULLI RIBEIRO; LARANJA, A. C.; ALVAREZ, CE de. Avaliação de desempenho entre as tipologias de aberturas zenital e lateral no quesito iluminação natural de ambientes internos. Cadernos Proarq, v. 31, p. 83-99, 2018.
[5] MAPELLI-BASILIO, Y. R. et al. Desempenho luminoso de shed integrado a prateleira de luz em ambiente de circulação. ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, v. 18, n. 1, p. 1-8, 2020.
[6] SCHMIDLIN, Flavio; SILVA, Felipe Tavares da; "Investigation of indoor daylight performance of the two-sided roof monitor system solution space", p. 237-248 . In: XXVI International Conference of the Iberoamerican Society of Digital Graphics. São Paulo: Blucher, 2023.
[7] FANG, Yuan; CHO, Soolyeon. Design optimization of building geometry and fenestration for daylighting and energy performance. Solar Energy, v. 191, p. 7-18, 2019.
[8] RAMOS, Milena Ronconi; LARANJA, Andréa Coelho. Desempenho luminoso de ambiente interno a partir de aberturas zenitais: estudo de caso em sala de aula. ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, v. 18, 2025.
[9] VITÓRIA. Lei n°. 4821, de 30 de dezembro de 1998. Código de Edificações do Município de Vitória. Vitória, 1998. Disponível em: https://leismunicipais.com.br/codigo-de-obras-vitoria-es.
[10] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR 15215-3: Iluminação natural – Parte 3: Procedimentos para avaliação da iluminação natural em ambientes internos. Rio de Janeiro: ABNT, 2024.
[11] MARDALJEVIC, J.; ANDERSEN, M.; ROY, N.; CHRISTOFFERSEN, J. “Daylighting metrics: is there a relation between useful daylight illuminance and daylight glare probabilty?”. In: Proceedings of the building simulation and optimization conference. BSO12. 2012.
[12] REINHART, C.; WALKENHORST, O. “Validation of dynamic radiance-based daylight simulations for a test office with external blinds”. Energy and Buildings, Freiburg, v. 33, n. 1, p. 683-697, jan. 2001.
[13] LIU, Binyan et al. A study on daylighting metrics related to the subjective evaluation of daylight and visual comfort of students in China. Energy and Buildings, v. 287, p. 113001, 2023.