Adaptive behavior in classrooms in a tropical climate

implications for indoor air quality

Authors

DOI:

https://doi.org/10.46421/entac.v21i1.8588

Keywords:

Occupant behavior, Indoor air quality, Thermal comfort, Classrooms, Tropical climate

Abstract

This study investigates the determinants of occupant behaviour in classrooms in a tropical savanna climate without informational intervention. The research was based on experimental monitoring of environmental, behavioural, and contextual variables. Operational actions, such as air-conditioning use and the opening of windows and doors, were analysed in relation to air temperature, CO₂ concentration, and occupancy density. Logistic regression analysis indicated that occupant behaviour is predominantly driven by thermal variables, whereas CO₂ concentration did not trigger adaptive actions, even under progressive accumulation. The results reveal a disconnect between indoor air quality and occupant behaviour, highlighting the need to make non-sensory environmental variables perceptible to users.

Author Biographies

  • João Henrique Alves da Silva, Universidade Federal de Santa Catarina

    Doutorando em Arquitetura e Urbanismo na Universidade Federal de Santa Catarina (Florianópolis - SC, Brasil). Professor do Ensino Básico, Técnico e Tecnológico do Instituto Federal de Educação, Ciência e Tecnologia de Mato Grosso do Sul (Jardim - MS, Brasil).

  • Renata Cordeiro Peguin, Instituto Federal de Educação, Ciência e Tecnologia de Mato Grosso do Sul

    Mestrado em Estudos Culturais pela Universidade Federal de Mato Grosso do Sul (Aquidauana - MS).

  • Renata De Vecchi, Universidade Federal de Santa Catarina

    Doutorado em Engenharia Civil na Universidade Federal de Santa Catarina (Florianópolis - SC). 

  • Martin Gabriel Ordenes Mizgier, Universidade Federal de Santa Catarina

    Doutorado em Engenharia Civil na Universidade Federal de Santa Catarina (Florianópolis - SC). Professor do Magistério Superior na Universidade Federal de Santa Catarina (Florianópolis - SC).

References

MENDELL, M. J.; HEATH, G. A. Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature. Indoor Air, v. 15, n. 1, p. 27–52, 2005. DOI: 10.1111/j.1600-0668.2004.00320.x

FISK, W.; WARGOCKI, P.l; XIAOJING, Z. Do indoor CO 2 levels directly affect perceived air quality, health, or work performance?. Ashrae Journal, v. 61, n. 9, 2019.

TWARDALLA, D.; et al. Effect of classroom air quality on students’ concentration: results of a cluster-randomized cross-over experimental study. Indoor Air, v. 22, n. 5, p. 378–387, 2012. DOI: 10.1111/j.1600-0668.2012.00774.x

BERARDI, U. A cross-country comparison of the building energy consumptions and their trends. Resources, Conservation and Recycling, v. 123, p. 230–241, 2017. DOI: 10.1016/j.resconrec.2016.03.014.

CHINAZZO, G.; et al. Quality criteria for multi-domain studies in the indoor environment: Critical review towards research guidelines and recommendations. Building and Environment, v. 226, p. 109719, 2022. DOI: 10.1016/j.buildenv.2022.109719.

KIM, J.; DE DEAR, R. Nonlinear relationships between individual IEQ factors and overall workspace satisfaction. Building and Environment, v. 49, p. 33–40, 2012, DOI: 10.1016/j.buildenv.2011.09.022

SCHWEIKER, M.; et al. Review of multi-domain approaches to indoor environmental perception and behaviour. Building and Environment, v. 176, p. 106804, 2020. DOI: 10.1016/j.buildenv.2020.106804.

ZHAO, Y.; LI, D. Multi-domain indoor environmental quality in buildings: A review of their interaction and combined effects on occupant satisfaction. Building and Environment, v. 228, p. 109844, 2023, DOI: 10.1016/j.buildenv.2022.109844.

FRANCESCHINI, P. B.; SCHWEIKER, M.; NEVES, L. O. Predictive modelling of multi-domain factors on window, door, and fan status in naturally ventilated school classrooms. Building and Environment, v. 264, n. June, p. 111912, 2024. DOI: 10.1016/j.buildenv.2024.111912.

BERNARDI, N.; KOWALTOWSKI, D. C. C. K. Environmental comfort in school buildings: A case study of awareness and participation of users. Environment and behavior, v. 38, n. 2, p. 155-172, 2006. DOI: 10.1177/0013916505275307.

GHISI, E.; BAVARESCO, M.; SILVESTRE, A. G. C. Avaliação do comportamento de usuários em escritórios compartilhados em Florianópolis: estudo de caso sobre janelas, luminárias e aparelhos de ar-condicionado. Ambiente Construído, v. 24, p. e132319, 2024. DOI: 10.1590/s1678-86212024000100707.

BALVEDI, B. F.; GHISI, E.; LAMBERTS, R. A review of occupant behaviour in residential buildings. Energy and Buildings, v. 174, p. 495–505, 2018. DOI: 10.1016/j.enbuild.2018.06.049.

VERMA, A.; et al. Tropical climates and the interplay between QAI and energy consumption in buildings: A review. Building and Environment, v. 242, p. 110551, 2023. DOI: 10.1016/j.buildenv.2023.110551.

BASTIEN, D.; et al. The impact of real-time carbon dioxide awareness on occupant behavior and ventilation rates in student dwellings. Energy and Buildings, v. 310, p. 114132, 2024. DOI: 10.1016/j.enbuild.2024.114132.

VELLEI, M.; et al. The effect of real-time context-aware feedback on occupants’ heating behaviour and thermal adaptation. Energy and Buildings, v. 123, p. 179-191, 2016. DOI: 10.1016/j.enbuild.2016.03.045

SILVA, J. H. A.; et al. Impact of visual CO₂ and thermal comfort indicators on adaptive behaviour and energy use in classrooms in a tropical climate. In: PLEA 2026 – Passive and Low Energy Architecture Conference, 2026, Costa Rica. Anais... [S.l.: s.n.], 2026. No prelo.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 17037:2023. Qualidade do ar interior em ambientes não residenciais climatizados artificialmente – Padrões referenciais. Rio de Janeiro, 2023.

SILVA, J. H. A.; et al. Validação do sistema de um sinalizador visual como ferramenta de previsão das condições de conforto térmico em ambientes escolares. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 20., 2024. Anais [...]. Porto Alegre: ANTAC, 2024. p. 1–18. DOI: 10.46421/entac.v20i1.6217.

ARENS, E.; et al. Are ‘class A’temperature requirements realistic or desirable?. Building and Environment, v. 45, n. 1, p. 4-10, 2010.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR 16401-3: Instalações de ar-condicionado — Sistemas centrais e unitários — Parte 3: Qualidade do ar interior. Rio de Janeiro: ABNT, 2008.

AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS. ANSI/ASHRAE Standard 62.1-2025: Ventilation and Acceptable Indoor Air Quality. Atlanta: ASHRAE, 2025.

Published

2026-10-07

Issue

Section

Conforto Ambiental e Eficiência Energética

How to Cite

SILVA, J. H. A. DA et al. Adaptive behavior in classrooms in a tropical climate: implications for indoor air quality. NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, v. 21, n. 1, 7 Oct.2026.

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

1-10 of 15