Who controls building interfaces in classrooms?
DOI:
https://doi.org/10.46421/entac.v21i1.8590Keywords:
Occupant behavior, Indoor air quality, Thermal comfort, Classrooms, Tropical climateAbstract
This study investigates the influence of occupants on the control of environmental conditions in classrooms located in a tropical climate. The research combined environmental monitoring, records of actions on building interfaces, and questionnaires under two scenarios: without and with environmental information provided through a visual indicator. CO₂ concentration, thermal comfort, and occupants’ actions on windows, doors, and air-conditioning systems were analyzed. The results show that, without environmental information, no natural ventilation actions occurred even under critical CO₂ levels. With the introduction of the visual indicator, adaptive actions increased and CO₂ concentrations decreased. It is concluded that occupant behavior is conditioned by contextual factors and by the distribution of responsibilities, with information alone being insufficient to promote consistent behavioral change.
References
BERARDI, U. A cross-country comparison of the building energy consumptions and their trends. Resources, Conservation and Recycling, v. 123, p. 230–241, 2017. DOI: 10.1016/j.resconrec.2016.03.014.
D’OCA, S.; HONG, T.; LANGEVIN, J. The human dimensions of energy use in buildings: A review. Renewable and Sustainable Energy Reviews, v. 81, p. 731-742, 2018.Dong et al., 2018. DOI: doi.org/10.1016/j.rser.2017.08.01
SCHWEIKER, M.; et al. Review of multi-domain approaches to indoor environmental perception and behaviour. Building and Environment, v. 176, p. 106804, 2020. DOI: 10.1016/j.buildenv.2020.106804.
O'BRIEN, W.; et al. Introducing IEA EBC Annex 79: Key challenges and opportunities in the field of occupant-centric building design and operation. Building and Environment, v. 178, p. 106738, 2020. DOI: 10.1016/j.buildenv.2020.106738.
VERMA, A.; et al. Tropical climates and the interplay between QAI and energy consumption in buildings: A review. Building and Environment, v. 242, p. 110551, 2023. DOI: 10.1016/j.buildenv.2023.110551.
SATISH, U.; et al. Is CO2 an indoor pollutant? Direct effects of low-to-moderate CO2 concentrations on human decision-making performance. Environmental health perspectives, v. 120, n. 12, p. 1671-1677, 2012. DOI: 10.1289%2Fehp.1104789.
ZHANG, X.; et al. Effects of exposure to carbon dioxide and bioeffluents on perceived air quality, self‐assessed acute health symptoms, and cognitive performance. Indoor air, v. 27, n. 1, p. 47-64, 2017. DOI: 10.1111/ina.12284.
SILVA, J. H. A.; et al. Impact of visual CO₂ and thermal comfort indicators on adaptive behaviour and energy use in classrooms in a tropical climate. In: PLEA 2026 – Passive and Low Energy Architecture Conference, 2026, Costa Rica. Anais... [S.l.: s.n.], 2026. No prelo.
SHAUGHNESSY, R. J.; et al. A preliminary study on the association between ventilation rates in classrooms and student performance. Indoor air, v. 16, n. 6, 2006. DOI: 10.1111/j.1600-0668.2006.00440.x
CHATZIDIAKOU, L.; MUMOVIC, D.; SUMMERFIELD, A. Is CO2 a good proxy for indoor air quality in classrooms? Part 1: The interrelationships between thermal conditions, CO2 levels, ventilation rates and selected indoor pollutants. Building Services Engineering Research and Technology, v. 36, n. 2, p. 129-161, 2015a. DOI: 10.1177/0143624414566244.
BERNARDI, N.; KOWALTOWSKI, D. C. C. K. Environmental comfort in school buildings: A case study of awareness and participation of users. Environment and behavior, v. 38, n. 2, p. 155-172, 2006. DOI: 10.1177/0013916505275307.
PISTORE, L.; et al. Analysis of subjective responses for the evaluation of the indoor environmental quality of an educational building. Science and Technology for the Built Environment, [S. l.], v. 0, n. 0, p. 000, 2019. DOI: 10.1080/23744731.2019.1649460.
WARGOCKI, P.; WYON, D. P. Ten questions concerning thermal and indoor air quality effects on the performance of office work and schoolwork. Building and Environment, v. 112, p. 359-366, 2017. DOI: 10.1016/j.buildenv.2016.11.020.
BASTIEN, D.; et al. The impact of real-time carbon dioxide awareness on occupant behavior and ventilation rates in student dwellings. Energy and Buildings, v. 310, p. 114132, 2024. DOI: 10.1016/j.enbuild.2024.114132.
SILVA, J. H. A.; et al. Validação do sistema de um sinalizador visual como ferramenta de previsão das condições de conforto térmico em ambientes escolares. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 20., 2024. Anais [...]. Porto Alegre: ANTAC, 2024. p. 1–18. DOI: 10.46421/entac.v20i1.6217.