Exploração do espaço de soluções termo lumínicas de dispositivo cinético de sombreamento de fachada em clima quente
DOI:
https://doi.org/10.46421/entac.v21i1.8695Keywords:
Sombreamento cinético, Iluminância, Temperatura operativa, Percentis, Desempenho de fachadasAbstract
Kinetic shading devices can reduce overheating and glare, yet thermal–daylighting assessments still often rely on mean-based metrics that are not easily comparable across scenarios. This study evaluates, through computational simulation and automated post-processing, a kinetic façade device applied to a shoebox model across 12 scenarios (WWR 0.4/0.6/0.9; orientations 0°, 90°, 180° and 270°, corresponding to North, East, South and West), comparing two operational states: SEM (baseline) and COM (device active). Thermal performance is summarized by annual extremes using the temporal 95th percentile (Tp95), while daylight performance is assessed using annual climate-based metrics framed as useful range and excess (UDI 100–2000 lx). Results show Tp95 reductions between 10.0% and 31.2% (4.57°C to 14.46°C), with stronger effects for WWR = 0.9, whereas changes in useful-range/excess daylight metrics are small and scenario-dependent. Temporally validated data-driven inference (E→T) suggests a regime shift between SEM and COM, supporting the assessment and control of adaptive building envelopes under a future EPW climate file for João Pessoa, Paraíba, Brazil.
References
[1] RIBEIRO, L. L.; WESTPHAL, F. S.; GHISI, E. Avaliação do desempenho energético de edificações com o uso de vidros laminados e insulados no Nordeste do Brasil. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO (ENTAC), 19., 2022, Canela. Anais… Porto Alegre: ANTAC, 2022.
[2] SILVA, F. T.; VERAS, J. C. G. A design framework for a kinetic shading device system for building envelopes. Frontiers of Architectural Research, v. 12, p. 837-854, 2023.
[3] DAKHEEL, J. A.; AOUL, K. T. Building applications, opportunities and challenges of active shading systems: a state-of-the-art review. Energies, v. 10, n. 10, 2017.
[4] HOSSEINI, S. M. et al. A morphological approach for kinetic façade design process to improve visual and thermal comfort: review. Building and Environment, v. 153, p. 186-204, 2019.
[5] TABADKANI, A. et al. Integrated parametric design of adaptive facades for user's visual comfort. Automation in Construction, v. 106, 2019.
[6] AYOUB, M. Integrating illuminance and energy evaluations of cellular automata controlled dynamic shading system using new hourly-based metrics. Solar Energy, v. 170, p. 336-351, 2018.
[7] NABIL, A.; MARDALJEVIC, J. Useful daylight illuminances: A replacement for daylight factors. Energy and Buildings, v. 38, n. 7, p. 905-913, 2006.
[8] ABNT. NBR 15215-4:2005. Iluminação natural — Parte 4: Verificação experimental das condições de iluminação natural interna. Rio de Janeiro: ABNT, 2005.
[9] ABNT. NBR 15215-3:2005. Iluminação natural — Parte 3: Procedimentos para avaliação da iluminação natural em ambientes internos. Rio de Janeiro: ABNT, 2005.
[10] SAMADI, S.; NOORZAI, E.; BELTRÁN, L. O.; ABBASI, S. A computational approach for achieving optimum daylight inside buildings through automated kinetic shading systems. Frontiers of Architectural Research, v. 9, p. 335-349, 2020.
[11] VAN VUUREN, D. P. et al. The representative concentration pathways: an overview. Climatic Change, v. 109, p. 5-31, 2011.
[12] IPCC. Climate Change 2014: Synthesis Report. Geneva: IPCC, 2014.
[13] ROUDSARI, M. S.; PAK, M. Ladybug: a parametric environmental plugin for Grasshopper to help designers create an environmentally-conscious design. In: Proceedings of BS2013, 2013.