Hygrothermal Performance of Light Steel Framing Facade Systems: A Comparative Analysis under Different Brazilian Climate Conditions

Authors

  • Mauricio Marques Resende University of São Paulo image/svg+xml
  • Luciana Alves Oliveira INSTITUTO DE PESQUISAS TECNOLÓGICAS DO ESTADO DE SÃO PAULO - IPT
  • Paula Naomi Yonamine University of São Paulo image/svg+xml
  • Cláudia Teresinha Andrade de Oliveira University of São Paulo image/svg+xml

DOI:

https://doi.org/10.46421/entac.v21i1.8697

Keywords:

Hygrothermal performance, Light steel frame, Computer simulation, Condensation

Abstract

The hygrothermal performance of Light Steel Frame (LSF) wall systems represents one of the main challenges for their application in different Brazilian climatic zones, especially due to the influence of humidity, driving rain, and land use and occupancy conditions. This work aims to evaluate the hygrothermal behavior of two LSF wall configurations subjected to different climatic conditions, represented by the cities of Recife, São Paulo, and Curitiba. Simulations were performed using WUFI Pro software. The results indicate that hygrothermal performance strongly depends on the interaction between the construction system and climate; that is, there is no universally optimal construction solution, and it is necessary to adapt construction strategies to local climatic conditions.

Author Biographies

  • Mauricio Marques Resende, University of São Paulo

    Mestrado em construção civil pela Escola Politécnica da USP. Doutorando em Arquitetura, Tecnologia pela Faculdade de Arquitetura e Urbanismo da USP (São Paulo - SP, Brasil)

  • Luciana Alves Oliveira, INSTITUTO DE PESQUISAS TECNOLÓGICAS DO ESTADO DE SÃO PAULO - IPT

    Doutorado em construção civil pela Escola Politécnica da USP (São Paulo - SP, Brasil).

  • Paula Naomi Yonamine, University of São Paulo

    Engenheira civil pela Escola Politécnica da USP.

  • Cláudia Teresinha Andrade de Oliveira, University of São Paulo

    Doutorado em Engenharia Civil pela Universidade de São Paulo (São Paulo - SP, Brasil)

References

[1] HENRIQUES, F. M. A. Humidade em paredes. Lisboa: Laboratório Nacional de Engenharia Civil, 1994.

[2] SEDLBAUER, K. Prediction of mould fungus formation on the surface of and inside building components. Stuttgart: Fraunhofer Institute, 2001.

[3] STRAUBE, J. Moisture in buildings. ASHRAE Journal, Atlanta, 2002.

[4] MENDES, N. Modelos para previsão da transferência de calor e umidade em elementos porosos de edificações. 1997. Tese (Doutorado) – Universidade Federal de Santa Catarina, Florianópolis, 1997.

[5] KÜNZEL, H. M. Simultaneous heat and moisture transport in building components. Stuttgart: Fraunhofer IRB Verlag, 1995.

[6] BLOCKEN, B.; CARMELIET, J. A review of wind-driven rain research in building science. Journal of Wind Engineering and Industrial Aerodynamics, v. 92, p. 1079–1130, 2004. DOI: https://doi.org/10.1016/j.jweia.2004.06.003.

[7] ZANONI, V. A. G. Agentes de degradação climática e o comportamento higrotérmico de fachadas. 2015. Tese (Doutorado) – Universidade de Brasília, Brasília, 2015.

[8] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR 15575-1: Edificações habitacionais – Desempenho – Parte 1: Requisitos gerais. Rio de Janeiro, 2025.

[9] INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. ISO 13788: Hygrothermal performance of building components and building elements – Internal surface temperature to avoid critical surface humidity and interstitial condensation – Calculation methods. Geneva, 2012

[10] INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. ISO 15026-1: Hygrothermal performance of building components and building elements – Assessment of moisture transfer by numerical simulation – Part 1: General procedures. Geneva, 2007.

[11] ASHRAE. ANSI/ASHRAE Standard 160: Criteria for moisture-control design analysis in buildings. Atlanta, 2016.

[12] DEROME, D.; Kubilay, A.; DEFRAEYE, T; BLOCKEN, B.; CARMELIET, J. Ten questions concerning modeling of wind-driven rain in the built environment. Building and Environment, v. 114, 2017. https://www.sciencedirect.com/science/article/pii/S0360132316305212.

[13] HU, S.; LI, X.; ZHANG, Y. Numerical simulation study on the hygrothermal performance of building exterior walls under dynamic wind-driven rain condition. Building Simulation, v. 17, 2024.

DOI: https://doi.org/10.1007/s12273-023-1076-3.

[14] LIU, MEIRONG; HUANG, LINGJIANG; WANG, JUAN. Hygrothermal performance of exterior wall assemblies under wind-driven rain across China’s thermal zones. Journal of Building Engineering, v. 15, 2025. DOI: https://doi.org/10.3390/buildings15224198.

[15] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. Projeto de norma: Simulação computacional do comportamento higrotérmico de paredes – Procedimento. Rio de Janeiro, 2023.

[16] BERNARDES, L. C. Impacto da variação das condições de contorno no projeto de norma ABNT de simulação de transporte de umidade. 2024. Dissertação (Mestrado) – Universidade Federal de Pelotas, Pelotas, 2024.

[17] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR 15220-3: Desempenho térmico de edificações – Parte 3: Zoneamento bioclimático por desempenho. Rio de Janeiro, 2024.

[18] LAWRIE, L. K.; CRAWLEY, D, B. Development of Global Typical Meteorological Years (TMYx). 2022. Disponível em: https://climate.onebuilding.org. Acesso em: 24 set. 2025.”

[19] BRASIL. Ministério das Cidades. Sistema Nacional de Avaliação Técnica (SINAT): Diretriz para Avaliação Técnica de paredes estruturais de concreto moldadas no local: Concreto Leve ou Concreto Reforçado com Fibra de Vidro. Brasília, 2022.

Published

2026-10-09

Issue

Section

Tecnologias de Sistemas e Processos Construtivos

How to Cite

RESENDE, M. M. et al. Hygrothermal Performance of Light Steel Framing Facade Systems: A Comparative Analysis under Different Brazilian Climate Conditions. NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, v. 21, n. 1, 9 Oct.2026.

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)