Comparative Analysis Between Adiabatic and Integrated Zone Models in Building Thermal-Energy Simulation

Authors

  • Lucas Adler Rodrigues Procheira Universidade Federal de Santa Catarina image/svg+xml
  • Fernando Simon Westphal Universidade Federal de Santa Catarina image/svg+xml

DOI:

https://doi.org/10.46421/entac.v21i1.8777

Keywords:

Energy Efficiency, Computer Simulation, Adiabatic Model, Thermal Exchanges

Abstract

This study evaluates the impact of thermal exchanges through the surfaces of a commercial room on air-conditioning energy consumption, comparing the performance of a configuration with adiabatic walls against another with real thermal exchanges with neighboring environments. The methodology involved annual thermo-energy simulation using EnergyPlus software for the climate of Florianópolis/SC. Two main scenarios were analyzed: adiabatic and non-adiabatic, with thermal exchanges with adjacent rooms. The results indicate that the adiabatic model overestimates the cooling load and nullifies the heating demand. The study contributes by showing that thermal exchanges between a building's internal walls can have an important influence on the sizing of air-conditioning systems in subtropical climates. It is concluded that, although physical accuracy is ideal, simplifying the model by adopting the adiabatic approach remains viable for simplified parametric envelope studies, where the difference in total consumption results does not present significant relevance.

Author Biographies

  • Lucas Adler Rodrigues Procheira, Universidade Federal de Santa Catarina


    Mestrado em Arquitetura e Urbanismo na Universidade Federal de Santa Catarina. Doutorando em Arquitetura e Urbanismo na Universidade Federal de Santa Catarina (Florianópolis - SC, Brasil) 

  • Fernando Simon Westphal, Universidade Federal de Santa Catarina

    Doutorado em Engenharia Civil pela Universidade Federal de Santa Catarina. Professor Associado da Universidade Federal de Santa Catarina (Florianópolis - SC, Brasil)

References

[1] STRUCK, C.; HENSEN, J. On supporting design decisions in conceptual design addressing specification uncertainties using performance simulation. In: INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION CONFERENCE, 10., 2007, Pequim. Anais [...]. [S. l.]: IBPSA, 2007. p. 1434-1439.

[2] CRAWLEY, D. B.; HAND, J. W.; KUMMERT, M.; GRIFFITH, B. T. Contrasting the capabilities of building energy performance simulation programs. Building and Environment, v. 43, n. 4, p. 661-673, 2008.

[3] HENNINGER, R. H.; WITTE, M. J. EnergyPlus testing with building thermal envelope and fabric load tests from ANSI/ASHRAE Standard 140-2011. [S. l.]: U.S. Department of Energy, 2015.

[4] ATTIA, S.; BELTRÁN, L.; DE HERDE, A.; HENSEN, J. Architect friendly: a comparison of ten different building performance simulation tools. In: IBPSA CONFERENCE, 2012, Madison. Anais [...]. [S. l.]: IBPSA, 2012.

[5] CHEW, L. W. Buoyancy-driven natural ventilation: the role of thermal stratification and its impact on model accuracy. E3S Web of Conferences, 2023.

[6] MAGNI, M.; OCHS, F. Impact of zoning strategy on heating load, heating demand, comfort and air quality for a flat equipped with different ventilation systems. In: BUILDING SIMULATION CONFERENCE, 2024, Denver. Anais [...]. [S. l.: s. n.], 2024.

[7] ELHADAD, S.; RADHA, C. H. Model simplification on energy and comfort simulation analysis for residential building design in hot and arid climate. Energies, 2022.

[8] MARTINS PINTO, Mônica; SIMON WESTPHAL, Fernando. Condições de contorno externo de paredes internas: simular uma zona térmica adiabática ou integrada ao pavimento?. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 19., 2022. Anais [...]. Porto Alegre: ANTAC, 2022. p. 1–15. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/2010. Acesso em: 20 jun. 2026.

[9] CUCE, P. M.; CUCE, E. Role of HVAC in building energy consumption: a critical review. Journal of Thermal Analysis and Calorimetry, v. 151, p. 3059-3080, 2026.

[10] EFICIENTEDU. Plataforma de apoio ao ensino de eficiência energética e simulação computacional. [S. l.: s. n.], 2023. Disponível em: https://eficientedu.vercel.app. Acesso em: 30 ago. 2025.

[11] ENERGYPLUS. Input output reference: the encyclopedic reference to EnergyPlus input and output. Version 25.1.0. [S. l.]: U.S. Department of Energy, 2024. Disponível em: https://energyplus.net/assets/nrel_custom/pdfs/pdfs_v25.1.0/InputOutputReference.pdf. Acesso em: 9 set. 2025.

[12] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15220-2: desempenho térmico de edificações — parte 2: métodos de cálculo da transmitância térmica, da capacidade térmica, do atraso térmico e do fator solar de elementos e componentes de edificações. Rio de Janeiro, 2005.

Published

2026-09-05

Issue

Section

Conforto Ambiental e Eficiência Energética

How to Cite

PROCHEIRA, L. A. R.; WESTPHAL, F. S. Comparative Analysis Between Adiabatic and Integrated Zone Models in Building Thermal-Energy Simulation. NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, v. 21, n. 1, 5 Sept.2026.

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)