Evaluation of the acoustic performance of a classroom with rock wool panels
DOI:
https://doi.org/10.46421/entac.v21i1.8782Keywords:
Room acoustics, Reverberation time, Rock wool, Speech IntelligibilityAbstract
This study aims to evaluate the acoustic performance, focusing on the reverberation time, of a university classroom before and after installing rock wool panels on the walls, and to verify the influence of a fiberglass veil coating on sound absorption. The methodology consisted of in situ measurements according to the ISO 3382-1 standard and computer simulations using Sketchup and Raven software. The main results demonstrated that the average reverberation time of the empty room decreased from 1.57 seconds to values below 1.00 second at frequencies of 1, 2, and 4 kHz after the intervention, fitting the acoustic environment to the optimal parameters of the DIN 18041 standard. Furthermore, it was found that the use of the fiberglass veil did not alter the absorptive efficiency of the rock wool when compared to the uncoated option. The study's contribution lies in proving the feasibility of directly fixing these panels to the walls as a practical solution for the acoustic conditioning of classrooms.