Double skin façade, Daylight, WWD, Computational Parametric SimulationAbstract
This study aims to evaluate the influence of the window-to-wall ratio (WWR) in buildings with double-skin façades (DSF) on daylighting performance across different latitudes (30°S and 0°). The methodology consists of computational simulations conducted in Rhinoceros 3D and Grasshopper and Honeybee plugins, based on a building model that incorporates different façade opening ratios (WWR: 20%, 40%, and 60%), variations in glazing transmittance (41.8%, 62.2%, and 81.3%), and distinct DSF typologies. Daylighting performance was assessed using the sDA300,50% and UDI300–3000 metrics. The results indicate that the WWR is the primary parameter controlling daylighting performance, with the useful illuminance range varying from 26% (WWR 20%) to 52% (WWR 60%) in the case of the Box-Window typology with high-transmittance glazing. Glazing transmittance acts as a complementary factor, enhancing or attenuating these effects. In contrast, variations in façade typology and latitude showed a limited influence on daylighting performance.
References
[1] PHILLIPS, Derek. Daylighting: Natural Light in Architecture. 2004, DOI: 10.4324/9780080477053.
[2] MÜNCH, M. et al. The role of daylight for humans: gaps in current knowledge. 2020. DOI: https://doi.org/10.3390/clockssleep2010008.
[3] EDWARDS, L.; TORCELLINI, P. A literature review of the effects of natural light on building occupants. 2002. DOI: 10.2172/15000841.
[4] MARDALJEVIC, J. Useful daylight illuminance: a new paradigm for assessing daylight in buildings. 2005. DOI: https://doi.org/10.1191/1365782805li128oa.
[5] TABADKANI, A.; ROETZEL, A.; LI, H. X. Daylight in buildings and visual comfort evaluation: the advantages and limitations. 2021. DOI: https://dx.doi.org/10.15627/jd.2021.16.
[6] LEE, E. S. et al. Double skin facades: a literature review. 2002. DOI: https://doi.org/10.1051/e3sconf/202564101017.
[7] BARBOSA, Sabrina; IP, Kenneth. Perspectives of double skin façades for naturally ventilated buildings: A review. 2014. DOI: https://doi.org/10.1016/j.rser.2014.07.192.
[8] DEWI, O., RAHMASARI, K., HANJANI, T., ISMOYO, A., DUGAR, A. Window to Wall Ratio as a Mode of Daylight Optimization for an Educational Building with Opaque Double-SkinFaçade.2024. DOI: https://doi.org/10.5755/j01.sace.30.1.29744.
[9] ELAYEBA, O. K.; ALGHOUL, M. A.; SOPIAN, K.; KHRITA, N. G. Optimum design parameters of box window DSF office at different glazing types under sub interval of intermediate sky conditions (20–40 klux). 2017. DOI: 10.1051/e3sconf/20172305003.
[10] GHONIMI, I. Assessing daylight performance of single vs. double skin façade in educational buildings: a comparative analysis of two case studies. 2017. DOI: 10.5539/jsd.v10n3p133.
[11] BARBOSA, S.; ALBERTO, K. C.; PIROOZFAR, P. Natural daylighting through double skin façades: a review. Architectural Engineering and Design Management, 2024. DOI: 10.1080/17452007.2024.2400711.
[12] SOLEMMA INC. (2023). DIVA users: Try ClimateStudio today! ClimateStudio is the Successor to DIVA-for-Rhino. Disponível em: https://www.solemma.com/climatestudio.
[13] AGC Brasil. Sunlux Shadow 60: vidro de controle solar. Disponível em: https://agcbrasil.com/vidro-para-construcao-civil/vidros-de-controle-solar/sunlux-shadow-60/.
[14] KOEPPEN, W. (1948). Las zonas de clima. Em: W. Koeppen (Ed.), Climatología: Con un estudio de los climas de la Tierra.