Thermal performance of concrete and steel frame prototypes
a pilot study
DOI:
https://doi.org/10.46421/entac.v21i1.8911Keywords:
Thermal performance, thermal inertia, in-situ monitoring, construction systemsAbstract
This study compares the thermal performance of three prototypes (LSF, plain concrete, and concrete with EIFS) in Pelotas, Brazil, aiming to calibrate in-situ monitoring. Temperature data were collected every 10 minutes during the summer of 2026. The LSF system, characterized by low thermal inertia, showed the highest thermal variation (peaking at 38.3°C), reacting rapidly to external fluctuations. In contrast, the concrete prototypes demonstrated greater thermal stability due to their material mass. Solar gains from the northern orientation and technical limitations in sensor power supply influenced the results. It is concluded that thermal inertia is fundamental for performance in high-amplitude climates.
References
[1] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS, “NBR 15575: Edificações habitacionais - Desempenho,” 2021, RIO DE JANEIRO.
[2] R. Lamberts, L. Dutra, and F. O. R. Pereira, Eficiência Energética na Arquitetura, 3a Edição. Eletrobrás - PROCEL, 2014.
[3] C. Morishita, J. Berger, and N. Mendes, “Weather-based indicators for analysis of moisture risks in buildings,” Science of The Total Environment, vol. 709, p. 134850, Mar. 2020, doi: 10.1016/j.scitotenv.2019.134850.
[4] Associação Brasileira de Normas Técnicas, “NBR 15220 - 3: Desempenho térmico de edificações Parte 3: Zoneamento bioclimático brasileiro e diretrizes construtivas para habitações unifamiliares de interesse social,” 2005, ABNT, Rio de Janeiro.
[5] L. B. Buligon, M. da R. Macarthy, L. C. Bernardes, R. K. Leitzke, G. de C. Grigoletti, and E. G. da Cunha, “Desempenho higrotérmico de paredes de alvenaria em edificação residencial em clima subtropical úmido,” PARC Pesquisa em Arquitetura e Construção, vol. 13, p. e022029, Nov. 2022, doi: 10.20396/parc.v13i00.8667258.
[6] R. Hilbrecht, C. A. Cruickshank, C. Baldwin, and N. Scharf, “A Rapid Review of Hygrothermal Performance Metrics for Innovative Materials in Building Envelope Retrofits,” Energies (Basel)., vol. 18, no. 18, p. 5016, Sep. 2025, doi: 10.3390/en18185016.
[7] N. Mendes, F. S. Westphal, R. Lamberts, and J. A. B. da Cunha Neto, “Uso de instrumentos computacionais para análise do desempenho térmico e energético de edificações no Brasil,” Ambiente Construído, vol. 5, no. 4, pp. 47–68, Oct. 2005.
[8] J. O. Batista, R. Lamberts, and S. Güths, “Influências dos algoritmos de condução e convecção sobre os resultados de simulações do comportamento térmico de edificações,” Ambiente Construído, vol. 11, no. 4, pp. 79–97, Dec. 2011, doi: 10.1590/S1678-86212011000400007.
[9] R. M. e S. MACHADO, “Zoneamento bioclimático brasileiro,” https://labeee.ufsc.br/zoneamento.
[10] A. B. de N. T. ABNT, “ABNT NBR 15220-2 Desempenho térmico de edificações Parte 2 – Componentes e elementos construtivos das edificações — Resistência e transmitância térmica — Métodos de cálculo (ISO 6946:2017 MOD),” 2022, ABNT, Rio de Janeiro.
[11] LabEEE - Laboratório de Eficiência Energética em Edificações, “Projeteee – Projetando Edificações Energeticamente Eficientes,” https://projeteee.mme.gov.br/componentes-construtivos/.
[12] International Organization for Standardization, “ISO 7726:2025(en) Ergonomics of the thermal environment — Instruments for measuring and monitoring physical quantities,” 2025.