Comparison between outputs from softwares of hygrothermal performance analysis: EnergyPlus and WUFI Pro
DOI:
https://doi.org/10.46421/entac.v21i1.9015Keywords:
Hygrothermal performance, Computational simulation, HumidityAbstract
The hygrothermal performance of buildings is of great importance due to the adverse effects caused by high indoor humidity levels. However, national standards establishing criteria for satisfactory performance in this regard remain limited. Given this scenario, computational simulations were performed on a model representing a single-story residential building with a Light Wood Frame in the city of São Paulo, under occupied and unoccupied conditions, using EnergyPlus software—based on the Combined Heat and Moisture Transfer and Conduction Transfer Functions algorithms—and WUFI Pro. A comparison was made between the relative surface humidity profiles, and a significant difference was observed between the results, a fact that could lead to errors in technical evaluations. Although the Combined Heat and Moisture Transfer calculation algorithm better represents the physical phenomena involving moisture transport, it is not possible to conclude that it is preferable due to a lack of measurement data.
References
[1] CHRISTIAN, J. E. Moisture sources. In: TRECHSEL, H. R.; BOMBERG, M. T. Moisture control in buildings: the key factor in mold prevention. 2. ed. West Conshohocken: ASTM, 2009. p. 103–109.
[2] KUMARAN, M. K. Fundamentals of transport and storage of moisture in building materials and components. In: TRECHSEL, H. R.; BOMBERG, M. T. Moisture control in buildings: the key factor in mold prevention. 2nd. ed. West Conshohocken: ASTM, 2009. p. 1-15.
[3] FRAUNHOFER INSTITUTE FOR BUILDING PHYSICS. WUFI® Pro. Versão 6.6. Fraunhofer Institute for Building Physics, Holzkirchen, 2022.
[4] BAYAT POUR, M. et al. A literature review of probabilistic hygrothermal assessment for building envelopes. Building and Environment, v. 261, 111756, ago. 2024. DOI: https://doi.org/10.1016/j.buildenv.2024.111756
[5] BURGE, Harriet A. Moisture, organism and health effects. In: TRECHSEL, H. R.; BOMBERG, M. T. Moisture control in buildings: the key factor in mold prevention. 2. ed. West Conshohocken: ASTM, 2009. p. 80–86.
[6] GLOBAL INITIATIVE FOR ASTHMA. Global strategy for asthma management and prevention. Fontana: Global Initiative for Asthma, 2024.
[7] CAHILL, K. N. Acute exacerbations of asthma in adults: Emergency department and inpatient management. In: DIXON, A.; ZACHRISON, K. Disponível em: https://www.uptodate.cn/contents/acute-exacerbations-of-asthma-in-adults-home-and-office-management. Acesso em: 23 maio 2026.
[8] ALLEN, S. J. et al. Aflatoxin exposure, malaria and hepatitis B infection in rural Gambian children. Transactions of the Royal Society of Tropical Medicine and Hygiene, v. 86, n. 4, p. 426-430, 1992. DOI: https://doi.org/10.1016/0035-9203(92)90253-9
[9] UNSAL, H. et al. Genetic heterogeneity of hepatocellular carcinoma. Proceedings of the National Academy of Sciences, v. 91, n. 2, p. 822-826, jan. 1994. DOI: https://doi.org/10.1073/pnas.91.2.822
[10] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR15575-1: Edificações habitacionais - Desempenho - Parte 1: Requisitos gerais. Rio de Janeiro: ABNT, 2025.
[11] BRASIL. Ministério das Cidades, Programa Brasileiro da Qualidade e Produtividade no Habitat - PBQP-H. Sistema Nacional de Avaliações Técnicas - SiNAT. SINAT 001 - Revisão 04 - Diretriz para Avaliação Técnica de paredes estruturais de concreto moldadas no local: Concreto Leve ou Concreto Reforçado com Fibra de Vidro. Brasília, 2022.
[12] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. Rascunho Inicial do Projeto de Norma – Simulação computacional do comportamento higrotérmico de paredes – Procedimento. Rio de Janeiro: ABNT, 2023.
[13] INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. ISO 13788: Hygrothermal performance of building components and building elements — Internal surface temperature to avoid critical surface humidity and interstitial condensation — Calculation methods. Geneva, 2012.
[14] LAWRIE, L. K.; CRAWLEY, D. B. Development of Global Typical Meteorological Years (TMYx). 2024. Disponível em: https://climate.onebuilding.org. Acesso em: 19 set. 2025.
[15] GOFFART, J.; RABOUILLE, M.; MENDES, N. Uncertainty and sensitivity analysis applied to hygrothermal simulation of a brick building in a hot and humid climate. Journal of Building Performance Simulation, v. 10, n. 1, p. 37–57, 2015. DOI: https://doi.org/10.1080/19401493.2015.1112430
[16] YANG, J.; FU, H.; QIN, M. Evaluation of Different Thermal Models in EnergyPlus for Calculating Moisture Effects on Building Energy Consumption in Different Climate Conditions. Procedia Engineering, v. 121, p. 1635–1641, 2015. DOI: https://doi.org/10.1016/j.proeng.2015.09.194
[17] MACARTHY, M. R. et al. Análise comparativa do desempenho térmico em edifício histórico segundo dois algoritmos de cálculo de condução térmica. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 19., 2022, Canela. Anais [...] Porto Alegre: ANTAC, 2022. p. 1-16.