Comparação de abordagens computacionais na avaliação higrotérmica de paredes de concreto moldado in loco

Autores/as

  • Marta Baltar Alves UCS
  • Luciane Andreola Beber Universidade Federal de Pelotas image/svg+xml
  • Carolina de Mesquita Duarte Universidade Federal de Pelotas image/svg+xml
  • Stifany Knop Universidade Católica de Pelotas e Universidade Federal de Pelotas
  • Eduardo Grala da Cunha Universidade Federal de Pelotas image/svg+xml
  • Nathan Mendes Pontifícia Universidade do Paraná
  • Lais Zucchetti Universidade Federal do Rio Grande do Sul image/svg+xml

DOI:

https://doi.org/10.46421/entac.v21i1.8474

Palabras clave:

Umidade, Simulação higrotérmica, Paredes de concreto, Fungos

Resumen

Este artigo compara resultados de simulação higrotérmica obtidos com EnergyPlus e WUFI-Pro em paredes de concreto moldado in loco aplicadas a habitações de interesse social em Pelotas/RS (Zona Bioclimática 2R). Foram analisados dois sistemas: um sem isolamento térmico e outro com EPS externo, sob mesmas condições. As simulações foram realizadas de forma independente. Os resultados indicam convergência na temperatura superficial interna, mas diferenças no comportamento da umidade, evidenciando limitações dos modelos. O estudo analisa implicações para o desempenho higrotérmico e risco de fungos.

Referencias

REFERÊNCIAS

[1] MACEDO, J. W. N. et al. Manifestações patológicas causadas pela umidade. Revista Thema, Pelotas, v. 24, n. 2, 2025.

[2] LI, F.; LI, Q.; MENG, Q. Effect of moisture on thermal performance of walls. Applied Thermal Engineering, Oxford, v. 186, 2021.

[3] ZHANG, T. et al. Review on hygrothermal white-box models. Energy and Buildings, Lausanne, v. 305, 2024.

[4] XUE, Y. et al. The moisture distribution in wall-to-floor thermal bridges and its influence on mould growth. UCL Open: Environment, v. 4, 2022.

[5] SCHROEFFER, K. G.; PAGEL, É. C. Qualidade do ar interior em edifícios. PARC – Pesquisa em Arquitetura e Construção, Campinas, v. 16, 2025.

[6] OLIVEIRA, R. B.; ALVES, C. Desempenho térmico de habitações de interesse social com paredes de concreto. PARC – Pesquisa em Arquitetura e Construção, Campinas, v. 12, 2021.

[7] SANTOS, G. H.; OLIVEIRA, R. C.; RORIZ, M. Influência da umidade do ar no desempenho higrotérmico. Ambiente Construído, Porto Alegre, v. 21, n. 3, 2021.

[8] FONSECA, M. O.; MARINOSKI, D. L.; WESTPHAL, F. S. Impacto da revisão da NBR 15575. PARC – Pesquisa em Arquitetura e Construção, Campinas, v. 16, 2025.

[9] FRAUNHOFER IBP. WUFI® Pro 7: hygric and thermal simulation capabilities. Holzkirchen, 2024.

[10] BULIGON, L. B. et al. Hygrothermal performance of masonry walls in residential buildings. PARC – Pesquisa em Arquitetura e Construção, Campinas, v. 13, 2022.

[11] KÜNZEL, H. M. Simultaneous heat and moisture transport in building components. Stuttgart: Fraunhofer IRB Verlag, 1995.

[12] HENS, H. Building Physics: heat, air and moisture. 2. ed. Berlin: Ernst & Sohn, 2012.

[13] NEVANDER, L. E.; ELMARSSON, B. Moisture in building materials. Stockholm, 1994.

[14] KUMARAN, M. K. Moisture transport properties of building materials. Journal of Thermal Envelope and Building Science, v. 25, 2002.

[15] KUMARAN, M. et al. Moisture management of building envelopes. 2001.

[16] STRAUBE, J.; BURNETT, E. Building science for building enclosures. Westford: Building Science Press, 2005.

[17] ISO. ISO 13788: Hygrothermal performance of building components. Geneva, 2012.

[18] KÜNZEL, H. M.; KIESSL, K. Calculation of heat and moisture transfer in building components. International Journal of Heat and Mass Transfer, 1997.

[19] MENDES, N. et al. Heat, air and moisture transfer through porous media. 2003.

[20] VIITANEN, H. et al. Moisture and bio-deterioration risk of building materials. Journal of Building Physics, 2010.

[21] WHO. WHO guidelines for indoor air quality: dampness and mould. Copenhagen, 2009.

[22] COSTA, G.; FUCALE, S. Avaliação de desempenho térmico de habitações de interesse social com concreto. Research, Society and Development, 2022.

[23] PALANI, H. et al. Assessing hygrothermal performance in building walls. Sustainability, 2023.

[24] LIU, M. et al. Hygrothermal performance of exterior wall assemblies. Buildings, 2025.

[25] CRAWLEY, D. B. et al. EnergyPlus: creating a new-generation building energy simulation program. Energy and Buildings, 2020.

[26] U.S. DEPARTMENT OF ENERGY. EnergyPlus engineering reference. Washington, DC, 2023.

[27] IBGE. Cidades e Estados: Pelotas (RS). Rio de Janeiro, 2022.

[28] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15220-3: desempenho térmico de edificações – Parte 3: zoneamento bioclimático brasileiro e diretrizes construtivas para habitações unifamiliares de interesse social. Rio de Janeiro, 2024.

[29] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15575-1: edificações habitacionais – desempenho – Parte 1: requisitos gerais. Rio de Janeiro, 2022.

[30] MORISHITA, C. On the assessment of potential moisture risks in residential buildings across Brazil. 2020. Tese (Doutorado) – Pontifícia Universidade Católica do Paraná, Curitiba, 2020.

[31] DUARTE, C. M. Simulação do comportamento higrotérmico de habitações de interesse social. 2023. Dissertação (Mestrado) – Universidade Federal de Pelotas, Pelotas, 2023.

Publicado

2026-10-01

Número

Sección

Conforto Ambiental e Eficiência Energética

Cómo citar

BALTAR ALVES, M. et al. Comparação de abordagens computacionais na avaliação higrotérmica de paredes de concreto moldado in loco. ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, v. 21, n. 1, 1 oct.2026.

Artículos similares

1-10 de 50

También puede Iniciar una búsqueda de similitud avanzada para este artículo.

Artículos más leídos del mismo autor/a

1-10 de 21