Life cycle assessment of applied construction methods in hospital unit

Environmental impacts and reuse potential

Authors

DOI:

https://doi.org/10.46421/euroelecs.v6.8017

Keywords:

LCA, low environmental impact, building envelope, structural systems, construction materials

Abstract

This study evaluates the environmental impacts of a module from the INI/Fiocruz Hospital Center, which features enclosure systems made of self-supporting polyisocyanurate (PIR) panels. The assessment was conducted using the Life Cycle Assessment (LCA) methodology, following the impact categories specified in the CML 2002 method and using the Ecoinvent v. 3.6 database. First, a comparison was established with two scenarios: (i) a 30-year use scenario, including the reuse of all materials except the vinyl floor covering and the polyisocyanurate elements; (ii) a 30-year use scenario with full disposal of all materials. The results showed a reduction in the module’s overall environmental impact when transport and landfill disposal were avoided. Subsequently, a new interpretation was made based on scenario (i), to understand how the construction subsystems behave in the context of reuse, categorized into enclosure, roofing, and flooring. This analysis revealed that the flooring subsystem causes the most damage among the impact categories analyzed. It was concluded that the inclusion of post-use reuse stages can make the use of the prefabricated system containing polyisocyanurate environmentally compensatory, despite the high environmental cost during the production phase of its components.

Author Biographies

  • Nicole Melo de Boucherville Borges, Federal University of Rio de Janeiro

    Pursuing a Degree in Architecture and Urbanism at the Federal University of Rio de Janeiro (Rio de Janeiro – RJ, Brazil).

  • Thiago Melo Grabois, Federal University of Rio de Janeiro

    Ph.D. in Civil Engineering from the Federal University of Rio de Janeiro. Professor at the Faculty of Architecture and Urbanism of the Federal University of Rio de Janeiro (Rio de Janeiro, Brazil).

References

ABNT - ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR ISO 14.040:2006: Gestão Ambiental ⎼ Princípios e Estrutura. Rio de Janeiro, 2009.

GRABOIS, T. M.; CALDAS, L. R.; JULIÃO, N. R.; TOLEDO FILHO, R. D. An experimental and environmental evaluation of mortars with recycled demolition waste from a hospital implosion in Rio de Janeiro. Sustainability, v. 12, n. 21, p. 8945, 2020.

LLANTOY, N.; CHAFÉR, M.; CABEZA L. F. A comparative life cycle assessment (LCA) of different insulation materials for buildings in the continental Mediterranean climate. Energy & Buildings, n. 225, p. 110323, 2020.

MENDES, N. C.; BUENO, C.; OMETTO, A. R. Avaliação de impacto do ciclo de vida: revisão dos principais métodos. Production, n. 26, p. 160-175, 2016.

OLIVEIRA, A. C. R. T.; ALCÂNTARA, B. O. S.; PAULA, S. R. M.; CALDAS, L. R.; SILVOSO, M. M.; GRABOIS, T. M. Environmental evaluation of a prefab construction method employed to build the Evandro Chagas National Institute of Infectious Diseases. In: IOP Conference Series: Earth and Environmental Science. IOP Publishing, 2023.

REY-ALVAREZ, B.; SILVESTRE, J.; GARCÍA-MARTÍNEZ, A.; SÁNCHEZ-MONTAÑÉS, B. A comparative approach to evaluate the toxicity of building materials through life cycle assessment. Science of The Total Environment, v. 912, 2024.

THINGLEY, D. D.; HATHWAY, A.; DAVISON, B. An environmental impact comparison of external wall insulation types. Building and Environment, v. 85, p. 182-189, 2015.

Published

10-10-2025

How to Cite

Borges, N. M. de B., & Grabois, T. M. (2025). Life cycle assessment of applied construction methods in hospital unit: Environmental impacts and reuse potential. Latin American and European Meeting on Sustainable Buildings and Communities, 6(1), 1-10. https://doi.org/10.46421/euroelecs.v6.8017

Similar Articles

1-10 of 50

You may also start an advanced similarity search for this article.