Simulation of the thermal behavior of the facades of a block in the historic center of Viseu

Authors

DOI:

https://doi.org/10.46421/entac.v20i1.6235

Keywords:

Risk of condensation, Historic center, Three-dimensional modeling, Thermal behavior, CitySim

Abstract

This work aimed to simulate the thermal behavior of the facades of buildings in the historic center of Viseu, Portugal, for assessing the risk of surface condensation, using the CitySim program. A three-dimensional modeling of the selected block was carried out along with its calibration with the constructive information of the buildings and local climate. We highlighted the periods with risk of external surface condensation on the facades, demonstrating that such risk occurs during a significant percentage of the year. Comparisons were made between two hypothetical scenarios: the introduction of thermal insulation on the interior face of the building facades, resulting in an increase in risk percentage, and the simulation of the increase in outdoor temperatures in a possible climate-change scenario, which generated a decrease of the percentage of hours at risk of condensation. Furthermore, the work allowed us to understand the great versatility of the program and that the program can be used in multiple contexts.

Author Biographies

Alicia Vieira Sousa, Universidade Tecnológica Federal do Paraná

Graduada em engenharia civil pela Universidade Tecnológica Federal do Paraná (Curitiba - PR, Brasil).

Eduardo Leite Krüger, Universidade Tecnológica Federal do Paraná

Pós-doutorado na Ben-Gurion University of the Negev, Israel. Professor titular na Universidade Tecnológica Federal do Paraná (Curitiba - PR, Brasil).

Ricardo Manuel dos Santos Ferreira de Almeida, Instituto Politécnico de Viseu

Doutorado em Engenharia Civil na Faculdade de Engenharia da Universidade do Porto. Professor titular no Instituto Politécnico de Viseu (Viseu -Viseu, Portugal).

References

JESUS, P. P. Centro histórico de Viseu. Dissertação de Mestrado. Mestrado em Arquitetura (Ciclo de estudos integrado), Universidade da Beira Interior. Covilhã, Portugal, 2015. https://ubibliorum.ubi.pt/bitstream/10400.6/5274/1/4327_8305.pdf

BARRIENTOS, M. I. G. G.; QUALHARINI, E. L. Retrofit de construções: metodologia de avaliação. In: X Encontro Nacional de Tecnologia do Ambiente Construído. São Paulo, 2004.

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15575: Edificações habitacionais - Desempenho. Rio de Janeiro, 2013.

PIRES, J. R.; GONZALÉZ, M. A. S.; TUTIKIAN, B. F. Condensação Em Edificações: Uma Pesquisa Bibliográfica. Revista Conectus: tecnologia, gestão e conhecimento, 2021, 1.5.

AELENEI, D.; HENRIQUES, F... Analysis of the condensation risk on exterior surface of building envelopes. Energy and Buildings 40(10): 1866-1871, 2008. https://doi.org/10.1016/j.enbuild.2008.04.003.

THEBAULT, M. et al. A comparative study of simulation tools to model the solar irradiation on building façades. In: ISES solar world congress 2021. International Solar Energy Society, 2021. https://doi.org/10.18086/swc.2021.38.04

VERMEULEN, T.; KÄMPF, J. H.; BECKERS, B. Urban form optimization for the energy performance of buildings using Citysim. In: Proceedings of CISBAT 2013 cleantech for smart cities and buildings (2013): 915-920. https://infoscience.epfl.ch/entities/publication/4be93cc7-911f-4bf7-8f64-d514444f72cd

MOHAJERI, N.; GUDMUNDSSON, A.; KUNCKLER, T.; UPADHYAY, G.; ASSOULINE, D.; KÄMPF, J.; SCARTEZZINI, J. L. A solar-based sustainable urban design: The effects of city-scale street-canyon geometry on solar access in Geneva, Switzerland. Applied Energy 240: 173-190, 2019. https://doi.org/10.1016/j.apenergy.2019.02.014

DEC-Departamento Engenharia Civil. A cidade de Viseu. 2023. Disponível em: https://dep.estgv.ipv.pt/departamentos/dcivil/viseu/.

LNEC – Laboratório Nacional de Engenharia Civil. Coeficiente de Transmissão Térmica de Elementos da Envolvente dos Edifícios. 2006. https://pt.scribd.com/doc/283939592/Coeficientes-de-Transmissao-Termica-de-Elementos-Da-Envolvente-Dos-Edificios-LNEC-ITE-50/.

MENDONÇA, P. J. F. A. U. Habitar sob uma segunda pele: estratégias para a redução do impacto ambiental de construções solares passivas em climas temperados. Tese de doutoramento em Engenharia Civil. Universidade do Minho, Guimarães, Portugal, 2005. https://repositorium.sdum.uminho.pt/bitstream/1822/4250/14/TeseDoutMendonca14.pdf.

DORNELLES, K. A. Absortância solar de superfícies opacas: métodos de determinação e base de dados para tintas latex acrílica e PVA. Tese de Doutorado. Faculdade de Engenharia Civil, Arquitetura e Urbanismo. Universidade Estadual de Campinas, Campinas, 2008. https://doi.org/10.47749/T/UNICAMP.2008.429167

CARVALHO, D.; CARDOSO, S. P.; ROCHA, A. Future surface temperature changes for the Iberian Peninsula according to EURO-CORDEX climate projections. 2021. https://doi.org/10.1007/s00382-020-05472-3.

Published

2024-10-07

How to Cite

SOUSA, Alicia Vieira; KRÜGER, Eduardo Leite; ALMEIDA, Ricardo Manuel dos Santos Ferreira de. Simulation of the thermal behavior of the facades of a block in the historic center of Viseu. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 20., 2024. Anais [...]. Porto Alegre: ANTAC, 2024. p. 1–12. DOI: 10.46421/entac.v20i1.6235. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/6235. Acesso em: 23 nov. 2024.

Issue

Section

Conforto Ambiental e Eficiência Energética

Most read articles by the same author(s)

Similar Articles

<< < 19 20 21 22 23 24 25 26 27 28 > >> 

You may also start an advanced similarity search for this article.