IMPACTO DO ADENSAMENTO E VERTICALIZAÇÃO NA GERAÇÃO FOTOVOLTAICA DE FACHADA EM QUADRA NA ÁREA URBANA CENTRAL DE CHAPECÓ SC

Authors

  • Dyuliana R. Bolsoni Universidade Comunitária da Região de Chapecó
  • Greissi K. Z. Gheno Universidade Comunitária da Região de Chapecó
  • Isadora Z. Zardo Pesquisador Independente
  • Miguel T. G. Pacheco Pesquisador Independente

DOI:

https://doi.org/10.46421/entac.v18i.793

Keywords:

Photovoltaic generation, Distributed generation, Building integrated photovoltaics

Abstract

The distributed photovoltaic generation in Brazil complements hydroelectric generation, takes advantage of high levels of solar irradiation and reduces losses in transmission and distribution, allowing generating energy at the point of consumption. Roofs maximize photovoltaic generation, but high rise buildings present a limited area for a greater number of floors. Façade are lower efficiencies and more susceptible to shading, owing urban indexes, which are more impacting on buildings on the same block. Chapecó-SC is an example of the densification and verticalization of central urban areas with successive increases in building codes in the last decade. The objective is to analyze the impact of the maximum urban indexes in the city in a lot in the central urban area in the photovoltaic generation of the façade. Simulations are carried out with EnergyPlus 8.7, monthly module generation on the North, East and West façades. The location within the lot affected photovoltaic generation from 2918 to 1254 kWh/m²/year. In the months more shading, the modules installed on lower floors contributed to approximately half of total generation of the facades. However, photovoltaic modules should be installed on all floors and azimuth guidelines must favor solar incidacion in allotments.

References

DIDONÉ, Evelise Leite; WAGNER, Andreas; PEREIRA, Fernando Oscar Ruttkay. Avaliação dainfluência do contexto urbano na radiação solar para geração de energia. urbe. RevistaBrasileira de Gestão Urbana, [S. l.], v. 9, p. 408–424, 2017. DOI:10.1590/2175-3369.009.supl1.ao012.

GRIFFITH, B.; LONG, N.; TORCELLINI, P.; JUDKOFF, R.; CRAWLEY, D.; RYAN, J. Assessment of theTechnical Potential for Achieving Net Zero-Energy Buildings in the Commercial Sector, 2007.

Disponível em: http://www.nrel.gov/docs/fy08osti/41957.pdf.

IBGE. IBGE | censo 2010 | resultados | notícias | Censo 2010: população do Brasil é de190.732.694 pessoas. 2010. Disponível em:https://censo2010.ibge.gov.br/noticias-censo.html?busca=1&id=3&idnoticia=1766&t=censo-2010-populacao-brasil-190-732-694-pessoas&view=noticia. Acesso em: 26 fev. 2020.

IBGE. IBGE | Cidades@ | Santa Catarina | Chapecó | Panorama. 2020a. Disponível em:https://cidades.ibge.gov.br/brasil/sc/chapeco/panorama. Acesso em: 26 fev. 2020.

IBGE. IBGE | Cidades@ | Brasil | Panorama. 2020b. Disponível em:https://cidades.ibge.gov.br/brasil/panorama. Acesso em: 26 fev. 2020.

MICHALTHUK, Nadia. DI Online - Cresce o número de andares em edifícios de Chapecó.

Diário do Iguaçu, Chapecó, 2019. Disponível em:https://www.diariodoiguacu.com.br/noticias/detalhes/cresce-o-numero-de-andares-em-edificios-de-chapeco--49421. Acesso em: 27 fev. 2020.

PACHECO, Miguel; LAMBERTS, Roberto. Assessment of technical and economical viability forlarge-scale conversion of single family residential buildings into zero energy buildings in Brazil:Climatic and cultural considerations. Energy Policy, [S. l.], v. 63, p. 716–725, 2013. DOI:10.1016/j.enpol.2013.07.133.

RÜTHER, Ricardo; ZILLES, Roberto. Making the case for grid-connected photovoltaics in Brazil.

Energy Policy, [S. l.], v. 39, n. 3, p. 1027–1030, 2011. DOI: 10.1016/j.enpol.2010.12.021.

SANTOS, Arthur Henrique Cursino Dos. Avaliação técnica e financeira da geraçãofotovoltaica integrada à fachada de edifícios de escritórios corporativos na cidade de SãoPaulo. 2015. text - Universidade de São Paulo, [S. l.], 2015. Disponível em:http://www.teses.usp.br/teses/disponiveis/106/106131/tde-12022016-101152/. Acesso em: 2mar. 2016.

SORGATO, M. J.; SCHNEIDER, K.; RÜTHER, R. Technical and economic evaluation of thin-filmCdTe building-integrated photovoltaics (BIPV) replacing façade and rooftop materials inoffice buildings in a warm and sunny climate. Renewable Energy, [S. l.], v. 118, p. 84–98, 2018.

DOI: 10.1016/j.renene.2017.10.091.

Published

2020-11-04

How to Cite

BOLSONI, Dyuliana R.; GHENO, Greissi K. Z.; ZARDO, Isadora Z.; PACHECO, Miguel T. G. IMPACTO DO ADENSAMENTO E VERTICALIZAÇÃO NA GERAÇÃO FOTOVOLTAICA DE FACHADA EM QUADRA NA ÁREA URBANA CENTRAL DE CHAPECÓ SC. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.793. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/793. Acesso em: 23 nov. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Similar Articles

<< < 1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.