OTIMIZAÇÃO SIMPLIFICADA DE UMA PASSIVE HOUSE A PARTIR DO COMPORTAMENTO TERMOENERGÉTICO

Authors

  • Thaisa Rodrigues Universidade Federal de Pelotas
  • Kelly Aires Universidade Federal de Pelotas
  • Stifany Knop Universidade Católica de Pelotas
  • Maritza Macarthy Universidade Federal de Pelotas,
  • Eduardo da Cunha Universidade Federal de Pelotas

DOI:

https://doi.org/10.46421/entac.v18i.827

Keywords:

NBR15575, Optimization, Thermoenergetic performance, Passive house

Abstract

This paper aims to present a simplified optimization of a single-family residential building, with 126.45 m², in order to reach the maximization of the thermoenergetic performance. The verification was carried out through computational simulations with the software Energy Plus 8.7. The base model followed the configurations indicated in NBR15575 and was later optimized in a simplified way, through the increase of thermal insulation and shading of the glazed plans. The simulations were performed in two conditions, natural ventilation and artificial conditioning. The best optimization was resched when the building met the 5 principles of a passive house and the lowest thermal insulation compared with other simulations. This occurred with the addition of 4 cm of EPS in walls, 1 cm in the roof and 2 cm at floor, reaching approximately 33.88% of hours in thermal comfort throughout the year and a reduction in consumption of around 84.24%.

References

ABNT. Associação Brasileira de Normas Técnicas. NBR 15575 - 4: 2013. Edificações Habitacionais – Desempenho – Parte 4: Requisitos para os sistemas de vedações verticais internas e externas – SVVIE. 2013ASBEA. Associação Brasileira dos Escritórios de Arquitetura. Guia para Arquitetos na Aplicação da Norma de Desempenho – ABNT NBR 15.575. 2015. Disponível em: <https://www.caubr.gov.br/wp-content/uploads >. Acessado em junho, 2019.

ANSI/ASHRAE – AMERICAN NATIONAL STANDARD INSTITUTE / AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS. Standard – 55 - 2017 Thermal Environmental Conditions for Human Occupancy. Atlanta, 2017.

DALBEM, Renata; KNOP, Stifany; CUNHA, Eduardo G.; OLIVEIRA, Rui; RODRIGUES, Maria F.; VICENTE, Romeu. Verification of the Passive House Concept to the South of Brazil Climate.

Journal of Civil Engineering and Architecture (Online), v. 10, p. 937-945, 2016. Disponível em: <http://www.davidpublisher.com/Public/uploads/Contribute/57bfae38cfc38.pdf>. Acessado em agosto, 2019.

DALBEM, Renata; CUNHA, Eduardo G.; VICENTE, Romeu; FIGUEIREDO, António J.; SILVA, Antonio César S.B. Discussão do desempenho da envoltória de uma Passive House adaptada à zona bioclimática 2 em acordo com o RTQ-R. Ambiente Construído, v. 17, n. 1, p. 201-222, 2017. Disponível em: <http://www.scielo.br/scielo.php?pid=S1678-86212017000100201&script=sci_abstract&tlng=pt>. Acessado em agosto, 2019.

EPE. Empresa de Pesquisa Energética. Balanço Energético Nacional de 2019, ano Base 2018.

MME, 2019. Disponível em: <http://www.epe.gov.br/pt/publicacoes-dadosabertos/publicacoes/balanco-energetico-nacional-2019>. Acessado em junho, 2019.

INMETRO – INSTITUTO NACIONAL DE METROLOGIA, NORMALIZAÇÃO E QUALIDADE INDUSTRIAL.

RTQ-R. Requisitos Técnicos da Qualidade para o Nível de Eficiência Energética de Edifícios Residenciais. Rio de Janeiro, 2012.

MCLEOD, R., MEAD, K., STANDEN, M. Passivhaus primer: Designer’s guide A guide for the design team and local authorities. 2016. Disponível em http://www.passivhaus.org.uk/filelibrary/Primers/KN4430_Passivhaus_Designers_Guide_WEB.pdf. Acessado em agosto, 2020.

PACHEDO, R.; ORDÓÑEZ, J.; MARTÍNEZ, G. Energy efficient design of building: A review.

Renewable and Sustainable Energy Reviews. Espanha. 2012. Disponível em: <https://doi.org/10.1016/j.rser.2012.03.045>. Acessado em julho, 2019.

PALMER, J. Passivhaus Trust- The case for MVHR. Disponível em: <https://passivhaustrust.org.uk/guidance_detail.php?gId=46>. Acessado em agosto,2020.

POUEY, J. A-A. Projeto de Edificação Residencial Unifamiliar Para a Zona Bioclimática 2 Com Avaliação Termo Energética Por Simulação Computacional. Dissertação (Mestrado em Arquitetura), Universidade Federal de Pelotas, Pelotas, 2011.

SCHNIEDERS, J.; FEIST, W.; RONGEN, L. Passive Houses for different climate zones. Energy and Buildings, v. 105, 71–87, 2015. Disponível em: <https://doi.org/10.1016/j.enbuild.2015.07.032>. Acessado em agosto, 2019.

SOARES, M. M. Avaliação dos Parâmetros de Desempenho Térmico da NBR 15.575/2013: Habitações de Interesse Social na Zona Bioclimática 2. Dissertação (Mestrado em Arquitetura), Universidade Federal de Pelotas, Pelotas, 2014.

WANG, W.; RIVARD, H.; ZMEUREANU, R. Floor shape optimization for green building. Canadá.

2006. Disponível em: <https://doi.org/10.1016/j.aei.2006.07.001>. Acessado em julho, 2019.

Published

2020-11-04

How to Cite

RODRIGUES, Thaisa; AIRES, Kelly; KNOP, Stifany; MACARTHY, Maritza; CUNHA, Eduardo da. OTIMIZAÇÃO SIMPLIFICADA DE UMA PASSIVE HOUSE A PARTIR DO COMPORTAMENTO TERMOENERGÉTICO. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.827. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/827. Acesso em: 23 nov. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Similar Articles

<< < 32 33 34 35 36 37 38 39 40 41 > >> 

You may also start an advanced similarity search for this article.