The longer the better?

The impact of XRD measurement time on Portland clinker quantitative phase analysis results

Autores

  • Paulo Matos UDESC
  • José Andrade Neto Universidade do Estado de Santa Catarina image/svg+xml
  • Erich Rodríguez Universidade Federal de Santa Maria image/svg+xml
  • Ana Paula Kirchheim Universidade Federal do Rio Grande do Sul image/svg+xml

Palavras-chave:

X-ray diffraction, XRD, RQPA, Rietveld refinement, Portland clinker

Resumo

This work assessed the role of the XRD measurement time (0.5 to 40 h) and step sizes (0.010 and 0.020°) on the quantitative phase analysis of a Portland clinker. Synchrotron XRD was used as benchmarking. Rietveld quantitative phase analysis revealed that while the total C3S and C2S contents were not significantly affected by the measurement condition (among the laboratory XRD data), longer measurements (4 and 40 h) yielded higher C3S M3 contents, approaching the synchrotron data. Furthermore, measurement times of 0.5 and 1 h yielded higher orthorhombic C3A (double) and lower C4AF (2 wt%) than the 40 h measurement, related to the high signal overlapping of the aluminate phases. Increasing the measurement time reduced the Rwp value from 6.6 to 4.3. Overall, measurements longer than 2 h did not affect the total silicates contents nor the aluminates quantification (total and polymorphs), while C3S polymorphism quantification was not affected for measurements longer than 4 h.

Referências

H. Wang, Step Size, Scanning Speed and Shape of X-ray Diffraction Peak, 1994.

M.R. Rowles, The effect of data quality and model parameters on the quantitative phase analysis of X-ray diffraction data by the Rietveld method, J Appl Crystallogr 54 (2021) 878–894. https://doi.org/10.1107/S160057672100371X.

B.H. Toby, R factors in Rietveld analysis: How good is good enough? , Powder Diffr 21 (2006) 67–70. https://doi.org/10.1154/1.2179804.

P.R. De Matos, J.S. Andrade Neto, C.E.M. Campos, R. Snellings, R.E. Dinnebier, A.P. Kirchheim, Polymorphs and minor phases quantification in Portland clinker: Addressing challenges and foreign ion effects, Cem Concr Res (2025), In press.

P.R. de Matos, J.S. Andrade Neto, R.D. Sakata, A.P. Kirchheim, E.D. Rodríguez, C.E.M. Campos, Strategies for XRD quantitative phase analysis of ordinary and blended Portland cements, Cem Concr Compos 131 (2022) 104571. https://doi.org/10.1016/j.cemconcomp.2022.104571.

A. Kern, A.A. Coelho, R.W. Cheary, Convolution Based Profile Fitting, in: E.J. Mittemeijer, P. Scardi (Eds.), Diffraction Analysis of the Microstructure of Materials, 1st ed., Springer Berlin, Heidelberg, 2004: pp. 17–50. https://doi.org/10.1007/978-3-662-06723-9_2.

Downloads

Publicado

2025-07-24

Edição

Seção

ARTIGOS- Cimentos de Baixa Emissão de Carbono

Como Citar

Matos, P., Andrade Neto, J., Rodríguez, E., & Kirchheim, A. P. (2025). The longer the better? : The impact of XRD measurement time on Portland clinker quantitative phase analysis results. Simpósio Brasileiro de Ciência do Cimento (SBCC), 2(1). https://eventos.antac.org.br/sbcc/article/view/6515

Artigos Semelhantes

1-10 de 50

Você também pode iniciar uma pesquisa avançada por similaridade para este artigo.

Artigos mais lidos pelo mesmo(s) autor(es)

1-10 de 26