Estimation of consumption, leaks, and system pumping performance based on data from supervisory system
a case study
DOI:
https://doi.org/10.46421/sispred.v4.8170Keywords:
Sensors, Consumption indicators, Hourly consumption, Occupancy rate, Pumping costsAbstract
This study presents the results of analyses of water consumption and performance of pumping systems in the Brazilian Parliament Palace and Annex I. This is a quantitative analysis based on secondary data extracted directly from the supervisory system of the reservoirs and the pumping set. The data were processed and uploaded to Power BI, where several measurements were calculated to create graphs and tables of annual, monthly, weekly, daily, and hourly consumption, pump performance, estimation of leaks and occupancy. Losses due to leaks were estimated at 11.17%, approximately 2,327 m³ or R$ 83.9 thousand per year. The annual cost of electricity for pumping was estimated at R$ 8.9 thousand. Adopting a pumping system designed to avoid peak-hour operation by interconnecting the reservoirs with remotely operated partial-opening valves can reduce pumping costs by up to 23.7%. The operational efficiency of the system can be increased by interconnecting the reservoirs in an arrangement based on the concept of digital twins, incorporating the benefits of optimizing maintenance routines and reducing the risk of shortages. The estimated occupancy rate based on the average hourly consumption can be an important source for improving space management contracts, especially cleaning, security, and support services.
Downloads
References
ACERVO CÂMARA DOS DEPUTADOS - DEPARTAMENTO TÉCNICO. Documentação interna, 2025.
AGÊNCIA NACIONAL DE ÁGUAS. Manual de usos consuntivos da água no Brasil. Brasília: ANA, 2019. Disponível em: <https://www.snirh.gov.br/portal/snirh/centrais-de-conteudos/central-de-publicacoes/ana_manual_de_usos_consuntivos_da_agua_no_brasil.pdf>. Acesso em: 9 set. 2024.
AGÊNCIA NACIONAL DE ÁGUAS E SANEAMENTO BÁSICO. Impacto da mudança climática nos recursos hídricos do Brasil: sumário executivo. Brasília. Disponível em: <https://www.gov.br/ana/pt-br/assuntos/noticias-e-eventos/noticias/ana-lanca-estudo-sobre-impactos-da-mudanca-climatica-nos-recursos-hidricos-das-diferentes-regioes-do-brasil/resumo-executivo_26012024.pdf>. Acesso em: 9 set. 2024.
BANNISTER, P.; MUNZINGER, M.; BLOOMFIELD, C. Water benchmarks for offices and public buildings. Disponível em: <https://coloradowaterwise.org/Resources/Documents/ICI_toolkit/docs/ppab06/Australia%20Benchmarks%20for%20Office%20Buildings.pdf>. Acesso em: 20 maio 2025.
BINT, L.; VALE, R.; ISAACS, N. Water performance in New Zealand office buildings. In WATER NEW ZEALAND ANNUAL CONFERENCE 2011. Anais […] Nova Zelândia: 2011. Disponível em: <https://www.waternz.org.nz/Attachment?Action=Download&Attachment_id=947>. Acesso em: 22 maio 2025.
BOMA BEST. National Green Building Report. Disponível em: <https://bomabest.org/wp-content/uploads/2023/04/2020_BOMA_NGBR_English_191114-2.pdf>. Acesso em: 23 maio 2025.
BRASIL. Instituto Brasileiro de Geografia e Estatística. Disponível em: <https://www.ibge.gov.br/pt/inicio.html>. Acesso em: 9 set. 2024.
CASTRO, K. B. DE et al. Consumo de água tratada no Distrito Federal: um retrato pós crise hídrica. Brasília: 2021.
COSTA, B. DE P. Gémeo digital de gestão da água: aplicação à Câmara dos Deputados do Brasil. 2025. Dissertação (Mestrado em Engenharia Civil) - Universidade do Porto, Porto, 2025.
DODD, N. et al. Level(s)-A common EU framework of core sustainability indicators for office and residential buildings: Part 3, União Europeia, Luxemburgo, 2017. Disponível em: <https://susproc.jrc.ec.europa.eu/product-bureau/sites/default/files/2020-10/20201013%20New%20Level(s)%20documentation_1%20Introduction_Publication%20v1-0.pdf>. Acesso em: 17 mar. 2025.
FISK, W. J. et al. Economizer system cost effectiveness: Accounting for the influence of ventilation rate on sick leave. Lawrence Berkeley National Laboratory, 2003. Disponível em: <https://escholarship.org/uc/item/2px1f1mw>. Acesso em: 29 abr. 2025.
HACKBARTH, F. B. Modelagem do consumo de água em escritórios: estudo de caso na cidade de Joinville. 2021. Dissertação (Mestrado em Engenharia Civil) - Universidade do Estado de Santa Catarina, Joinville, 2021. Disponível em: <https://www.udesc.br/arquivos/cct/id_cpmenu/706/2021_07_27_Francisco_Barbosa_Hackbarth_16328560354174_706.pdf>. Acesso em: 29 maio 2025.
MURAKAWA, S.; IKEDA, D.; DOI, A. Estimation of water supply loads for the company cafeteria, hot-water service rooms and restrooms in an office building. In INTERNATIONAL SYMPOSIUM CIB W062 ON WATER SUPPLY AND DRAINAGE FOR BUILDINGS, 43rd. Haarlem. Anais [...], Holanda: 2017. Disponível em: <https://www.irbnet.de/daten/iconda/CIB_DC30478.pdf>. Acesso em: 23 maio 2025.
PROENÇA, L. C.; GHISI, E. Water end-uses in Brazilian office buildings. Resources, Conservation and Recycling, v. 54, n. 8, p. 489–500, 1 jun. 2010. Disponível em: <https://www.sciencedirect.com/science/article/pii/S0921344909002298>. Acesso em 3 jun. 2025.
RICE, P.; TYLER, B. Water efficiency benchmarks: commercial buildings. Disponível em: <https://www.watercorporation.com.au/-/media/WaterCorp/Documents/Help-and-advice/Waterwise-business-programs/Waterwise-office-program/commercial-office-water-efficiency-benchmarks-report.pdf>. Acesso em: 22 maio 2025.
SANTOS, C. et al. A study on the alternatives to potable water supply. In: INTERNATIONAL SYMPOSIUM CIB W062 ON WATER SUPPLY AND DRAINAGE FOR BUILDINGS, 37th. Aveiro. Anais [...], Portugal, 2011. Disponível em: . Acesso em: 22 maio 2025.
U.S. ENVIRONMENTAL PROTECTION AGENCY. US Energy Use Intensity by Property Type. Disponível em: <https://www.energystar.gov/sites/default/files/tools/National%20WUI%20Technical%20Reference%202023_0719b.pdf>. Acesso em: 23 maio 2025.
ZABOT, P. et al. Implicações práticas e teóricas de 21 anos de gestão hídrica na Câmara dos Deputados do Brasil. In SIMPÓSIO E2H EFICIÊNCIA ENERGÉTICA E HÍDRICA. Coimbra. Anais [...], Portugal, 2024.