Performance of pumpable concrete in vertical construction: effects of pumping on workability and compressive strength
DOI:
https://doi.org/10.46421/entac.v21i1.8500Keywords:
Pumpable concrete, Workability, Quality control, Vertical constructionAbstract
The study evaluates the performance of pumpable concrete in vertical construction, focusing on changes in workability during pumping and the comparison between fresh and hardened properties. The methodology involved slump and compressive strength tests in two buildings, with sampling at the truck discharge and at the placement point, at heights above 34 m, considering temperature, relative humidity, and pipe diameter as influencing variables. The results indicated slump losses between 10% and 20%, associated with height, smaller pipe diameters, and higher temperatures, being more pronounced in systems with higher pressure losses. Despite the rheological changes, compressive strength showed an average variation of approximately 5%, with no significant impact on mechanical performance. It is concluded that quality control performed only at the truck discharge does not adequately represent the concrete condition at the placement point, highlighting the need for monitoring throughout the process.
References
[1] NAÇÕES UNIDAS BRASIL. ONU-Habitat: população mundial será 68% urbana até 2050. Brasília, 2022. Disponível em: https://brasil.un.org/. Acesso em: 10 abril 2025.
[2] NEVILLE, A. M. Propriedades do concreto. 5. ed. Porto Alegre: Bookman, 2016.
[3] AMERICAN CONCRETE INSTITUTE. ACI 304.2R-17: placing concrete by pumping methods. Farmington Hills, MI, 2017.
[4] BANFILL, P. F. G.; TATTERSALL, G. H. Influence of superplasticizer additives in the production of concrete. Cement and Concrete Research, v. 13, n. 2, p. 323-333, 1983.
[5] CHOI, M. S.; ROUSSEL, N.; KIM, Y.; KIM, J. Lubrication layer properties during concrete pumping. Cement and Concrete Research, v. 45, p. 69-78, 2013.
[6] JACOBSEN, S.; HAUGAN, L.; HAMMER, T. A.; KALOGIANNIDIS, E. Flow conditions of fresh mortar and concrete in different pipes. Cement and Concrete Research, v. 39, n. 11, p. 997-1006, 2009.
[7] HICKEL, C. G. Concreto bombeável: parâmetros reológicos e influência na performance de bombeamento. 2022. Dissertação (Mestrado em Engenharia Civil) – Universidade Federal de Santa Catarina, Florianópolis, 2022.
[8] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 16889: Concreto - Determinação da consistência pelo abatimento do tronco de cone. Rio de Janeiro, 2020.
[9] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 5738: Concreto - Procedimento para moldagem e cura de corpos de prova. Rio de Janeiro, 2015.
[10] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 5739: Concreto - Ensaio de compressão de corpos de prova cilíndricos. Rio de Janeiro, 2018.
[11] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 7212: Execução de concreto dosado em central. Rio de Janeiro, 2024.
[12] JANG, K.; CHOI, M.; KIM, Y.; PARK, C.; SHAH, S. Experimental observation on variation of rheological properties during concrete pumping. International Journal of Concrete Structures and Materials, v. 12, 2018.
[13] MORTENSVIK, R.; THORSTENSEN, R. Rheological measurements of fresh concrete: a practical approach. Construction and Building Materials, v. 420, 2024.