ABSTRACT:

The search for efficiency in energy and water use brings new challenges. The technology employed and the measures taken to allow for the reduction of water and energy usage require a systemic approach, where many aspects related to the systems’ performance must be evaluated to verify the risks and benefits of the solution that will be adopted. This paper aims to evaluate the impacts of the usage of low flow showerheads in the hot water mixture process of hot water systems. The research comprises the development of the applicable theoretical reference and a case study done in a hotel in the city of São Paulo. The results show that the usage of low flow shower heads in hot water systems that employ higher hot water temperatures tend to difficult the water mixing process, creating more perceivable temperature fluctuations on the mixed water temperature that causes discomfort to the users. In particular, cases, the conditions create a risk of scalding. Hence, caution is recommended when using low flow showerheads, mainly on systems that employ higher hot water temperature.

Downloads

Download data is not yet available.

References

AMERICAN SOCIETY OF SANITARY ENGINEERS (ASSE). Scald Hazards Associated with Low-Flow Showerheads – A White Paper. Ohio. Acesso online. Disponível em: https://www.map-testing.com/assets/files/ASSE%20Scald%20Hazard%20White%20Paper.pdf. Acesso em 27 maio 2019.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS (ABNT). PN 02.146.03-003 29-05-13 Sistemas Prediais de Água Fria e Água Quente. Comissão de Estudo de Sistemas Predial Hidráulico-Sanitário para Água Fria e Quente. 2019.

ELETROBRAS. Avaliação do mercado de eficiência energética no Brasil: pesquisa de posse de equipamentos e hábitos de uso da classe residencial. Ano base 2005, Rio de Janeiro 2007.

FREIJE, M. Legionella Control in Healthcare Facilities – A Guide to Minimize Risk. Indianapolis, In – 1996.

MARTIN, R. L.; RICHARDSON, J. The Anti-Scald Issue, 1993 ASSE Zimmer Refresher Course, p. 36-38 & others.

TOMÉ, M. C. Análise do impacto do chuveiro elétrico em redes de distribuição no contexto da tarifa horossazonal. Dissertação (Mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação. Campinas. 2014.

Published

2019-10-04

How to Cite

YAMADA, Marco; HELENA DE OLIVEIRA, Lúcia. Evaluation of the impact of the use of low flow shower heads in the performance of hot water systems. In: SIMPÓSIO NACIONAL DE SISTEMAS PREDIAIS, 1., 2019. Anais [...]. Porto Alegre: ANTAC, 2019. DOI: 10.46421/sispred.v1i.1576. Disponível em: https://eventos.antac.org.br/index.php/sispred/article/view/1576. Acesso em: 22 jul. 2024.