Are light wells in residential building able to light environments?

Authors

DOI:

https://doi.org/10.46421/encac.v17i1.3759

Keywords:

daylighting, lighting well, illuminance

Abstract

The study starts from a recurring situation in housing settlements. It aims to bring contributions to the standard revision and to the municipal regulations with an impact on the daylight admission. The study developed 280 analysis of daylighting performance for a living room with a window facing a light well, located on the 1st and 4th floors of a multifamily housing unit, in Belo Horizonte - MG. The analysis used the prescriptive methodology of the NBR15.575/2013 standard and by computer simulation. The analysis of the external illuminance levels showed that on the 1st floor there is little availability of natural light in the well, causing reduced daylighting performance in the environment. The level of 48 lux, minimum level of NBR 15.575/2013, for the first floor was not reached. The widening of the diameter of the well from 3 to 6 meters (D3 and D6) does not significantly improve the daylighting conditions in the internal environment, which happens only in the vertical elevation of the environment to the upper floors. On the 4th floor the level of 60 lux was reached only with D6 diameter of the well. The adoption of internal and external walls with reflectance of 80% can increase this performance by approximately 80%, in relation to reflectance between 50-60%, especially in conditions in which there is no contribution of the sky component, and there is a high contribution of the internal and external reflected component, as is the case of environments facing the light well.

Keywords: daylighting, light well, illuminance.

Author Biographies

Karla Cristina de Freitas Jorge Abrahao, Universidade Federal de Minas Gerais

Doutora em Ambiente Construído e Patrimônio Sustentável pela Universidade Federal de Minas Gerais.

Janeth Vieira da Silva, Universidade Federal de Minas Gerais

Mestra em Ambiente Construído e Patrimônio Sustentável pela Universidade Federal de Minas Gerais.

Thaís Lobo, Universidade Federal de Minas Gerais

Aluna de graduação em Arquitetura e Urbanismo pela Universidade Federal de Minas Gerais.

Alice Oliveira, Universidade Federal de Minas Gerais

Aluna de graduação em Arquitetura e Urbanismo na Universidade Federal de Minas Gerais.

Roberta Vieira Gonçalves de Souza, Universidade Federal de Minas Gerais

Doutora em Engenharia Civil pela Universidade Federal de Santa Catarina. Professora Associada na Escola de Arquitetura da Universidade Federal de Minas Gerais.

Ana Carolina Oliveira Veloso, Universidade Federal de Minas Gerais

Doutora em Engenharia Mecânica pela Universidade Federal de Minas Gerais.

References

ABRAHÃO, K. C. de F. J.; SOUZA, R. G. V. de. Estimativa da evolução do uso final de energia elétrica no setor residencial do Brasil por região geográfica. Ambiente Construído, Porto Alegre, v. 21, n. 2, p. 383-408, abr./jun. 2021.

ABNT – ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15215-2: Iluminação natural - Parte 2: Procedimentos de cálculo para a estimativa da disponibilidade de luz natural. Rio de Janeiro, 2005a.

_____. NBR 15215-3: Iluminação natural - Parte 3: Procedimentos de cálculo para determinação da iluminação natural em ambientes internos. Rio de Janeiro, 2005b.

_____. NBR 15575-1: Edificações habitacionais - Desempenho - Parte 1: Requisitos gerais. 4 ed. Rio de Janeiro, 2013b.

ARAÚJO, I.A.L.; BITTENCOURT, L.S. Relação entre dimensões de janela e piso para iluminação natural e eficiência energética em edificações no trópico úmido. Ambiente Construído, Porto Alegre, v.22, n.4, p. 121-135, out./dez. 2018.

BOLSSONI, G.C.; LARANJA, A.C.; ALVAREZ, C.E. Disponibilidade de iluminação natural em ambiente interno orientado para poço de iluminação. Cadernos POARQ, Porto Alegre, v.5, n.4, p. 47-68, out./dez. 2005.

BRASIL ECONÔMICO. Atraso na aprovação do Minha Casa, Minha Vida 2 e rentabilidade maior em projetos de alto padrão motivou recuo no segmento popular São Paulo, mai.2022. Disponível em: Economia - iG @ https://economia.ig.com.br/empresas/comercioservicos/construtoras-se-voltam-para-media-e-alta-renda-no-1-trimestre/n1300120126360.html. Acesso em: 13 mai. 2019.

BUGEAT, A.; BECKERS, B.; FERNÁNDEZ, E. Improving the daylighting performance of residential light wells by reflecting an redirecting approaches. Solar Energy, 207, p.1434-1444, 2020.

GOOGLE MAPS. Conjunto Habitacional Bolivar de Freitas em Belo Horizonte. Disponível em: https://www.google.com/maps/search/belo+horizonte+e+conjunto+habitacional/@-19.8232076,-43.958547,92a,35y,339.47h,51.09t/data=!3m1!1e3. Acesso em: 23 mar. 2023.2023a.

_____. Conjunto Habitacional Residencial Mangueiras em Belo Horizonte. Disponível em: https://www.google.com/maps/search/belo+horizonte+e+conjunto+habitacional/@-19.959182,-43.9846613,144a,35y,257.16h,44.99t/data=!3m1!1e3. Acesso em: 23 mar. 2023. 2023b.

GUIDI, C. R.; ABRAHÃO, K. C. DE F. J.; VELOSO, A. C. O.; SOUZA, R. V. G. DE. Influência dos parâmetros urbanísticos e da topografia na admissão da luz natural em edifícios residenciais. Ambiente Construído, Porto Alegre, v. 18, n. 3, p. 49-66, jul./set. 2018.

LEAL, L.Q.; LEDER, S.M., Iluminação natural e ofuscamento: estudo de caso em edifícios residenciais multipavimentos. Ambiente Construído, Porto Alegre, v.18, n.4, p. 97-117, out./dez.2018.

LEDER, M.S.; PEREIRA, F.O.R.; CLARO, A. Janela de céu preferível: proposição de um parâmetro para controle da disponibilidade de luz natural no meio urbano. Ambiente Construído, Porto Alegre, v.8, n.1, p. 89-104, jan./mar.2008.

MARDALJEVIC, J. Rethinking daylighting and compliance. Journal of Sustainable Design and Applied Research, v. 1, n.3, p. 1-11, 2013.

_____. The implementation of natural lighting for human health from a planning perspective. Lighting Research and Technology, 2021; 53:p. 489-513.

OSIBONA, O.; SOLOMON, B.D.; FETCH, D. Lighting in the home and health: a systematic review. International Journal of Environmental Research and Public Health, 2021, 18(2):609. doi: 10.3390/ijerph18020609. PMID: 33445763; PMCID: PMC7828303.

PBH. PREFEITURA MUNICIPAL DE BELO HORIZONTE. Lei nº 9.725, de 15 de julho de 2009, que institui o Código de Edificações do Município de Belo Horizonte e dá outras providências, Anexo III. Diário Oficial do Município, Belo Horizonte, 2009. Disponível em: https://leismunicipais.com.br/codigo-de-obras-belo-horizonte-mg. Acesso em: 23 mar.2019.

PORTAL DA RMC. Programa Minha Casa Minha Vida em Monte-Mor atinge 70% de obras concluídas. Campinas, 02/2016. Disponível em: http://www.portaldarmc.com.br/noticias-da-regiao/2016/02/programa-minha-casa-minha-vida-em-monte-mor-atinge-70-de-obras-concluidas/. Acesso em: 13 mai. 2019.

REINHART, C. Daylighting Handbook I: Fundamentals designing with the sun – Volume I. Ed. Rian Stein. 2014.

_____. Daylighting Handbook II: Daylighting Simulations Dynamic Façades – Volume II. Ed. Rian Stein. 2018.

RELUX. Programa de simulação computacional ReluxDesktop. (2018). Disponível em: https://reluxnet.relux.com/en/relux-desktop.html. Acesso em 03/03/2019.

SCALCO, V. A.; PEREIRA, F. O. R. Método para a avaliação do impacto de edificações no acesso à iluminação natural em vizinhanças urbanas aplicado em cenários virtuais. Ambiente Construído, Porto Alegre, v. 16, n. 2, p. 169-187, abr./jun. 2016.

Published

26/10/2023

How to Cite

ABRAHAO, K. C. de F. J.; SILVA, J. V. da; LOBO, T. .; OLIVEIRA, A. I. de; SOUZA, R. V. G. de; VELOSO, A. C. O. Are light wells in residential building able to light environments? . In: ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, 17., 2023. Anais [...]. [S. l.], 2023. p. 1–10. DOI: 10.46421/encac.v17i1.3759. Disponível em: https://eventos.antac.org.br/index.php/encac/article/view/3759. Acesso em: 20 may. 2024.

Issue

Section

6. Iluminação Natural e Artificial

Most read articles by the same author(s)

<< < 1 2 3