Luminous performance of inclined reflectors in Vitória - ES

Authors

DOI:

https://doi.org/10.46421/encac.v17i1.3747

Keywords:

daylighting, inclined reflectors, reflective surfaces

Abstract

Buildings located in hot climates can receive large amounts of direct solar radiation, which damages the light
and thermal comfort of indoor users. Glazed side openings reconciled with solar control devices collaborate in
shading, as well as in redirecting and increasing the reflection of light to the internal environment, thus
enhancing the luminous performance of this environment. Thus, this article proposes to investigate the
luminous performance of inclined reflectors in Vitória - ES. The methodology covers the use of Solar
Geometry as well as computational simulation in an indoor environment. Ten models were tested with Inclined
Reflectors at 15°, 30° and 45° and reflectances of 0.2; 0.5; 0.9 plus a model without Inclined Reflector. The
simulations used the TropLux software, which generated illuminance data at 20 points of an orthogonal mesh
located in the environment. The simulated times were from 8:00 am to 4:00 pm for all days of the year with
opening facing North and South. To the south, the best UDI's (Useful Daylight Illuminances) results come
from Inclined Reflectors associated with the lowest reflection coefficients, regardless of the simulated
inclination. To the North, the variation of inclination provides differences in the ALN that reach 20% between
the models with reflectors, in which the model with the lowest slope associated with the highest reflectance
presented the best result. Still to the North, in relation to the UDI, the model with the lowest inclination and
highest reflectance also performed better, while the models inclined at 30° or 45° should be associated with
greater reflectance for better performance in the indoor environment.

Author Biographies

Maria Clara Friedrich Dadalto, Universidade Federal do Espírito Santo

Graduanda em Arquitetura e Urbanismo pela Universidade Federal do Espírito Santo (Vitória - ES, Brasil). Orientanda de Iniciação Científica. Estagiária na área de Planejamento Urbano na URBTEC TM (Curitiba - PR, Brasil).

Andréa Coelho Laranja , Universidade Federal do Espírito Santo

Doutorado em Ciências em Arquitetura pela Universidade Federal do Rio de Janeiro. Professor Associado II da Universidade Federal do Espírito Santo no Curso de Arquitetura e Urbanismo (Vitória - ES, Brasil).

References

ALVES NETTO, Ary Rodrigues. Melhoria no desempenho lumínico e energético de edifícios com prateleiras de luz. 2015. Dissertação de Mestrado em Estruturas e Construção Civil - Universidade Federal de São Carlos, São Carlos 2015.

ARAÚJO, Iuri Avila L.; CABÚS, Ricardo Carvalho. Influência da luz natural refletida pelo entorno na iluminação de edifícios em cânions urbanos no trópico úmido. Encontro Nacional de Conforto no Ambiente Construído, v. 9, 2007.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR ISO - CIE 8995: Iluminação em Ambientes de Trabalho. Rio de Janeiro: ABNT, 2013.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15215-4: Iluminação Natural. Parte 04: Verificação Experimental das condições de iluminação interna de edificações - Método de Medição. Rio de Janeiro: ABNT, 2005.

CARVALHO, Marlise Lila Silva; CABÚS, Ricardo Carvalho. Eficiência da luz solar refletida e desempenho de dispositivos de sombreamento. Ambiente Construído, v. 20, p. 191-209, 2020.

DA SILVA, Joene Saibrosa. Estratégias para luz natural: sistemas convencionais e brise-soleil como elemento de controle. Paranoá: cadernos de arquitetura e urbanismo, n. 3, p. 22-36, 2007.

FELIPPE, A. R. Desempenho luminoso e energético de vidros de controle solar e dispositivos de sombreamento. Dissertação (Mestrado) – Universidade Federal de Santa Catarina, Florianópolis, 2016.

LAM, William. Sunlighting as formgiver for architecture. 1985.

LARANJA, Andréa; FASSINA, Sirana. Balcões refletores e a disponibilidade da iluminação natural em salas de aula: O caso do Instituto Federal do Espírito Santo - Campus Colatina. SBE 16 Brazil & Portugal, 2016.

LM-83-12: IES Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE). New York, 2012.

MANHAS, Max Paulo Giacheto. Difusa ou especular? Estudando o desempenho da prateleira de luz segundo a refletância de sua superfície. 2016. 106 f. Dissertação de Mestrado em Dinâmicas do Espaço Habitado – Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, Universidade Federal de Alagoas, Maceió, 2016.

MARDALJEVIC, J. The implementation of natural lighting for human health from a planning perspective. Lighting Research & Technology, v. 53, n. 5, p. 489-513, 2021.

MARDALJEVIC, John et al. Daylighting metrics: is there a relation between useful daylight illuminance and daylight glare probabilty?. In: Proceedings of the building simulation and optimization conference BSO12. 2012.

PARK, Jihyun et al. Strategies to achieve optimum visual quality for maximum occupant satisfaction: Field study findings in office buildings. Building and Environment, v. 195, p. 107458, 2021.

VENÂNCIO, Raoni. Sombreamento com iluminação: desenvolvimento e teste de modelo paramétrico para facilitar o projeto de proteções solares. Ambiente Construído, v. 20, p. 59-77, 2020.

ZAMBONATO, Bruna et al. Influência do afastamento e da orientação solar na disponibilidade de iluminação natural em ambiente de geometria profunda para Santa Maria, RS. ENCAC, v. 18, n. 1, p. 1-8, 2020.

Published

2023-10-26

How to Cite

DADALTO, Maria Clara Friedrich; LARANJA , Andréa Coelho. Luminous performance of inclined reflectors in Vitória - ES. In: ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, 17., 2023. Anais [...]. [S. l.], 2023. p. 1–10. DOI: 10.46421/encac.v17i1.3747. Disponível em: https://eventos.antac.org.br/index.php/encac/article/view/3747. Acesso em: 22 jul. 2024.

Issue

Section

6. Iluminação Natural e Artificial