Desempenho térmico versus reação ao fogo
o equívoco no uso das embalagens longa-vida
DOI:
https://doi.org/10.46421/encac.v17i1.4158Keywords:
thermal performance, fire safety, carton packagingAbstract
“Longa-vida” packages are being used as an alternative to improve thermal performance in single-family wooden houses. Their usage is backed by environmental matters, to reuse these solid residues, attempting to use them as a radiant barrier for heat transmission. Because of that, using this material for that purpose became a viable alternative, both economically and environmentally for low-cost edifications. Although, published studies analyzed just the thermal insulation efficiency of the material, leaving matters, such as fire safety, unattended. Regarding that, the objective of this research is to understand the behavior of this material when exposed to a fire situation. For such, since this is a combustible material, fire reaction tests were conducted, following the parameters from the Brazilian standard ABNT NBR 16626:2017. The results showed that the material is indeed combustible, being evaluated as a class VI material by the methodology of special materials. Therefore, based on the found results, it is evident that "Longa-Vida" packages shouldn’t be used in civil construction.
References
ABNT – ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 16626: Classificação da reação ao fogo de produtos de construção. Rio de Janeiro, p. 35. 2017.
ABNT – ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 9442: Materiais de construção - Determinação do índice de propagação superficial de chama pelo método do painel radiante. Rio de Janeiro, p. 20. 2019.
AMERICAN SOCIETY FOR TESTING AND MATERIALS. ASTM E662: Standard Test Method for Specific Optical Density of Smoke Generated by Solid Materials. Estados unidos, p. 26. 2021.
BRASIL SEM FRESTAS. Tutorial para revestimento interno com embalagens Tetra Pak. Disponível em: http://caixadeleite- brasilsemfrestas.blogspot.com/2017/07/tutorial-para-revestimento-de-casas-de.html. Acesso em: 30 jul. 2022.
BRITISH STANDARDS INSTITUTION. BS EN 13823: Reaction to fire tests for building products. Building products excluding floorings exposed to the thermal attack by a single burning item. Reino Unido, p. 108. 2020
CORPO DE BOMBEIROS DA POLÍCIA MILITAR DO ESTADO DE SÃO PAULO. Controle de materiais de acabamento e de revestimento – Instrução Técnica n° 10. São Paulo, 2019.
ECYCLE. Iniciativa reutiliza embalagem Tetra Pak para restaurar casas precárias. Disponível em: https://www.ecycle.com.br/brasil-sem-frestas-embalagem-tetra-pak/. Acesso em: 31 jul. 2022.
FIORELLI, Juliano; MORCELI, J. A. B; DIAS, R. I. V. &. A. A. Avaliação da eficiência térmica de telha reciclada à base de embalagens longa vida. AGRIAMBI, Campina Grande, PB, UAEA/UFCG, v. 13, n. 2, p. 204-209, dez./2009.
GALLO, Jorge B.; AGNELLI, J. A. M. Aspectos do Comportamento de Polímeros em Condições de Incêndio. Revista Polímeros, Poços de Caldas, MG, v. 8, n. 1, p. 23-38, dez./1998. Disponível em: https://revistapolimeros.org.br/journal/polimeros/article/doi/10.1590/S0104-14281998000100005. Acesso em: 31 jul. 2022.
GZH. Conheça o projeto que transforma caixa de leite em isolante térmico para casas. Disponível em: https://gauchazh.clicrbs.com.br/comportamento/noticia/2019/04/conheca-o-projeto-que-transforma-caixa-de-leite-em- isolante-termico-para-casas-cju35rhrp00z301nvwzwyf8a5.html. Acesso em: 31 jul. 2022.
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. ISO 1182: Reaction to fire tests for products - Non- combustibility test. Suíça, p.31. 2020.
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. ISO 11925-2: Reaction to fire tests — Ignitability of products subjected to direct impingement of flame — Part 2: Single-flame source test. Reino Unido, p.27. 2020.
KREITH, Frank. Princípios da Transferência de Calor. Pioneira Thomson Learning, São Paulo, SP, 2003.
NASCIMENTO, R. M. de M., Viana, M. M. M., Silva, G. G., & Brasileiro, L. B. (2007). Embalagem cartonada longa vida: Lixo ou luxo. Química Nova na Escola, 25, 3-7.
SEBEEN, T. et al. Análise de desempenho térmico de uma moradia informal revestida com embalagens cartonadas. ENCAC, ELACAC, Palmas, TO, v. 1, n. 16.12, p. 539-548, out./2021.
SILVA, V. P. Segurança Contra Incêndio em Edifícios: Considerações para o Projeto de Arquitetura. Brasil: Blucher, 2020. TETRAPAK. Material das embalagens cartonadas da Tetra Pak. Disponível em: https://www.tetrapak.com/pt-
br/solutions/packaging/packaging-material/materials. Acesso em: 30 jul. 2022.
VITTORINO et al. Desempenho térmico de isolantes refletivos e barreiras radiantes aplicados em coberturas. ENCAC, Curitiba – PR, v. 1, n. 7, p. 1277-1284, nov./2003.
ZANELLA, Kelen; FOIATO, Maiara; CARELLI, Jhulis Marina. Avaliação do desempenho térmico de coberturas com a substituição de manta térmica por embalagens Tetra Pak-®. Conhecimento em Construção, Joaçaba, SC, v. 9, n. 1, p. 53- 74, jun./2022. Disponível em: https://unoesc.emnuvens.com.br/conhecconstr/article/view/30070. Acesso em: 31 jul. 2022.