ANÁLISE DA INFLUÊNCIA DO SOLO NO DESEMPENHO TÉRMICO DE AMBIENTES SUBTERRÂNEOS EM UMA EDIFICAÇÃO TÉRREA

Autores

  • Bruna Cristina Resende
  • Henor Artur de Souza
  • Adriano Pinto Gomes
  • Pablyne Sant'ana Cristeli

DOI:

https://doi.org/10.46421/entac.v17i1.1386

Palavras-chave:

Thermal performance, EnergyPlus, Basement preprocessor

Resumo

Among the several factors that interfere with the thermal performance of buildings, soil temperature is not always considered in thermal performance evaluations. One of the main factors contributing to this scenario is the high complexity of soil consideration in thermal performance analyzes, mainly due to the three-dimensional and transient character of the heat exchange processes involving the soil and the underground walls of a building. However, soil temperature is a factor that influences the final result of heat exchanges in the environment, especially in ground-level buildings. Thus, this work evaluates the soil influence as an active medium in the thermal performance evaluation, adopting as a computational tool the Basement preprocessor of the EnergyPlus software. By using this preprocessor it is possible to analyze the soil influence from the data generated by the program in relation to internal temperatures and losses and heat gains of the environment. Results suggest that when the soil influence is neglected in the thermal analyzes the internal temperature of subterranean rooms increases up to 7.3 ºC when compared to the situation where the soil influence is considered.

Referências

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15220: Desempenhotérmico de edificações 5 Partes. Rio de Janeiro, 2005.

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15575: Edificaçõeshabitacionais - Desempenho. Rio de Janeiro, 2013.

BRASIL. Ministério das Minas e Energia. Balanço Energético Nacional 2016. Brasília, DF,2016. Disponível em <https://ben.epe.gov.br/>. Acesso em: 12 mar. 2018.

BRASIL. Ministério das Minas e Energia. Balanço Energético Nacional 2017. Brasília, DF,2017. Disponível em <https://ben.epe.gov.br/>. Acesso em: 12 mar. 2018.

CLEMENTS, E. Three Dimensional Foundation Heat Transfer Modules for Whole-BuildingEnergy Analysis. 2004. 133 f. Tese (Doutorado em Ciências) - Pennsylvania StateUniversity, Pennsylvania, 2004.

COSTA, V. A. C. da; RORIZ, V. F.; CHVATAL, K. M. S. Modeling of slab-on-grade heattransfer in EnergyPlus simulation program. Ambiente Construído, Porto Alegre, v. 17,n. 3, p. 117-135, jul./set. 2017. ISSN 1678-8621 Associação Nacional de Tecnologia doAmbiente Construído. http://dx.doi.org/10.1590/s1678-86212017000300166DEPARTMENT of Energy Efficiency and Renewable Energy. EnergyPlus. Version 8.6.0.

US, 2016. Disponível em: <https://energyplus.net/downloads>. Acesso em: 02 jan.2018.

FERREIRA, C. C. Análise de Sensibilidade por meio de Experimento Fatorial deParâmetros de Desempenho Térmico de Envoltórias de Edificações Residenciais:Contribuição à Revisão das Normas Brasileiras. 2016. 437f. Tese (Doutorado emEngenharia Civil). Universidade Federal de Ouro Preto. Ouro Preto, 2016.

KRARTI, M. Ground-coupled heat transfer: A chapter in advances in solar energy.

ASES publication, p. 90, 1999.

OKE, T. R. Boundary Layer Climates. 2 ed. reimp. Inglaterra, UK: British Library, 1995.460 p.587

Downloads

Publicado

2018-11-12

Como Citar

RESENDE, Bruna Cristina; SOUZA, Henor Artur de; GOMES, Adriano Pinto; CRISTELI, Pablyne Sant'ana. ANÁLISE DA INFLUÊNCIA DO SOLO NO DESEMPENHO TÉRMICO DE AMBIENTES SUBTERRÂNEOS EM UMA EDIFICAÇÃO TÉRREA. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 17., 2018. Anais [...]. Porto Alegre: ANTAC, 2018. p. 580–587. DOI: 10.46421/entac.v17i1.1386. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1386. Acesso em: 22 dez. 2024.

Edição

Seção

(Inativa) Conforto Ambiental e Eficiência Energética

Artigos Semelhantes

1 2 3 4 5 6 7 8 9 10 > >> 