REDUÇÃO DOS DIÂMETROS DE RAMAIS NOS SISTEMAS PREDIAIS DE ESGOTOS SANITÁRIOS

Autores

  • Bruno Baroni
  • Lucia Helena de Oliveira
  • Fernanda V Comas

DOI:

https://doi.org/10.46421/entac.v17i1.1779

Palavras-chave:

Building drainage system, Water efficient use, Diameter reduction

Resumo

Sanitary equipment has been improved to become more efficient due the water availability concerns. One consequence may be the impact on the pipes of building drainage system, while using less water in operation, lead to the formation of smaller waves contributing to a poor self-cleaning of pipes. In this sense, this research investigates, in the laboratory, the flows and depths of the flow in drains of a residential building drainage system, under variation of slope, presence or not of continuous flow and pipe diameters, in order to reduce diameters from 100 mm to 75 mm. It was concluded that the reduction of the diameters of the drains contribute to the increase of the velocity of the wave in this part of the system. It was observed that the slope variation does not influence in general performance of the system and the presence of a permanent flow on drain has a negative impact

Referências

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15097: Aparelhos sanitáriosde material cerâmico Parte 1: Requisitos e métodos de ensaios. Rio de Janeiro,2011.

LANDI, F.R. A evolução histórica das instalações hidráulicas. BT/PCC/100. SãoPaulo, 1993.

McDOUGALL, J.A.; SWAFFIELD, J.A. Simulation of building drainage under waterconservation. Building Services Research and Technology, v. 21, n.1, p. 41-51. 2000.

McDOUGALL, J.A.; SWAFFIELD, J.A. Influence of water conservation on drain sizing forbuilding drainage systems. Building Services Engineering Research and Technology,v.24, n.1, p. 229-243. 2003.

OLIVEIRA, L.H. Estudo do escoamento em condutores horizontais de coleta deesgotos sanitários de edifícios residenciais. São Paulo, 1991. Dissertação (Mestradoem Engenharia Civil) - Escola Politécnica, Universidade de São Paulo,São Paulo,1991.

PLUMBING EFFICIENCY RESEARCH COALITION - PERC. Report: The drainline transportof solid waste in buildings - Phase 1, 2012. Disponível em:<http://www.plumbingefficiencyresearchcoalition.org/wpcontent/uploads/2012/12/Drainline-Transport-Study-PhaseOne.pdf> Accesso em: 1 dez 2017.

PLUMBING EFFICIENCY RESEARCH COALITION - PERC. Report: The drainline transportof solid waste in buildings - Phase 2.1, 2016. Disponível em:<http://www.plumbingefficiencyresearchcoalition.org/wpcontent/uploads/2016/04/PERC-2-0_2-1-FINAL.pdf> Accesso em: 1 Fev 2017.

SWAFFIELD, J.A. Dry drains: myth, reality or impediment to water conservation. In:WATER SUPPLY AND DRAINAGE FOR BUILDINGS CIBW062 SYMPOSIUM, 2009, Germany.Dusseldorf, 2009, p. 301-313.

SWAFFIELD, J.A.; GALLOWIN L.S. Hydraulics Horizontal Pitched Drains Based onVertical Stack to Drain Entry Condition. In: WATER SUPPLY AND DRAINAGE FORBUILDINGS CIBW062 SIMPOSIUM, 1985, Tokyo. Tokyo, 1985, 29 p.

SWAFFIELD, J.A.; GALLOWIN L.S. Multistory building drainage network design anapplication of computer based unsteady partially filled pipe flow analysis. Buildingand Environment, v.24, n.1, p. 99-110. 1989.

Downloads

Publicado

2018-11-12

Como Citar

BARONI, Bruno; OLIVEIRA, Lucia Helena de; COMAS, Fernanda V. REDUÇÃO DOS DIÂMETROS DE RAMAIS NOS SISTEMAS PREDIAIS DE ESGOTOS SANITÁRIOS. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 17., 2018. Anais [...]. Porto Alegre: ANTAC, 2018. p. 3482–3492. DOI: 10.46421/entac.v17i1.1779. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1779. Acesso em: 23 dez. 2024.