POTENCIAL DE APROVEITAMENTO DA VENTILAÇÃO NATURAL NA CLASSIFICAÇÃO DE EFICIÊNCIA ENERGÉTICA DE UMA EDIFICAÇÃO DE ESCRITÓRIOS:

APLICAÇÃO DA FERRAMENTA NATURAL COMFORT

Authors

  • Gabrielli Posca Doria Universidade Federal de Santa Catarina -UFSC
  • Emeli Lalesca Aparecida da Guarda Universidade Federal de Santa Catarina (UFSC)
  • Larissa Pereira de Souza Universidade Federal de Santa Catarina (UFSC)
  • Renata De Vecchi Universidade Federal de Santa Catarina (UFSC)
  • Greici Ramos Universidade Federal de Santa Catarina
  • Ana Paula Melo Universidade Federal de Santa Catarina
  • Michele Fossati Universidade Federal de Santa Catarina
  • Roberto Lamberts Universidade Federal de Santa Catarina

Keywords:

Offices, Thermal Cooling Load, Metamodel

Abstract

The constant growth of air conditioning use in office buildings highlight the importance of passive design options incorporation such as natural ventilation, to thus save energy. This paper aim is to evaluate the potential of the natural ventilation use together with other parameters that impacts on the energy efficiency classification of an office building located in Manaus-AM; to do so, the Natural Comfort tool included in the Inmetro Normative Instruction for the Energy Efficiency Classification of Commercial, and Public Service Buildings (INI-C) will be used. The methodological procedures are: i) building’s data collection as inputs values for the interfaces use; ii) definition of the hot discomfort hour fraction due to occupation; iii) total annual envelope thermal load calculation; and iv) energy efficiency classification. The results indicated that tilting windows combined with the ceiling fans use represented the higher reductions related to the numbers of thermal discomfort hours when compared to the same condition without ceiling fans use. Also, the natural ventilation use considering the best parameters combination modified the energy efficiency classification from B to A, with 30% of the annual thermal load reduction compared to the reference condition, equivalent to the D level.

Published

2023-10-02

How to Cite

DORIA, Gabrielli Posca; GUARDA, Emeli Lalesca Aparecida da; SOUZA, Larissa Pereira de; VECCHI, Renata De; RAMOS, Greici; MELO , Ana Paula; FOSSATI, Michele; LAMBERTS, Roberto. POTENCIAL DE APROVEITAMENTO DA VENTILAÇÃO NATURAL NA CLASSIFICAÇÃO DE EFICIÊNCIA ENERGÉTICA DE UMA EDIFICAÇÃO DE ESCRITÓRIOS:: APLICAÇÃO DA FERRAMENTA NATURAL COMFORT. In: ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, 16., 2021. Anais [...]. [S. l.], 2021. p. 1429–1438. Disponível em: https://eventos.antac.org.br/index.php/encac/article/view/4574. Acesso em: 21 nov. 2024.