The aim of this study is to define the energy efficiency classification for the Brazilian Regulation for residential buildings. a reference case, based on the minimum standards defined by NBR 15575. A database of 1 million cases was defined to fully explore the potential of different building characteristics. The results from cooling and heating thermal loads for each case were obtained from the simplified method of the new regulation, based on a metamodel developed through artificial neural networks. The energy efficiency classification was determined based on the relative differences of the thermal loads between all cases and their reference cases. The relative difference results for each label were specified for different climates, zone areas and use patterns.

Referências

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS - ABNT. NBR 15575-1: Edifícioshabitacionais - Desempenho: parte 1: Requisitos gerais, in, Associação Brasileira deNormas Técnicas, Rio de Janeiro, 2013.

BRASIL. Lei n. 10.295, de 17 de outubro de 2001. Dispõe sobre a Política Nacional deConservação e Uso Racional de Energia. Brasília, DF, 2001b. Disponível em:<http://www.planalto.gov.br/ccivil_03/leis/LEIS_2001/ L10295.htm>. Acesso em: 15março de 2018.

CENTRO BRASILEIRO DE EFICIÊNCIA ENERGÉTICA EM EDIFICAÇÕES CB3E.

Classificação de climas brasileiros empregada na atualização dos RegulamentosTécnicos da Qualidade para o Nível de Eficiência Energética de Edificações. 2017.

Disponível em: <http://cb3e.ufsc.br/sites/default/files/Relatorio_GruposClimaticos.

pdf>. Acesso em: março de 2018.

CENTRO BRASILEIRO DE EFICIÊNCIA ENERGÉTICA EM EDIFICAÇÕES CB3E. Novométodo de avaliação energética de edificações com base em energia primária.

2017. Disponível em: <http://cb3e.ufsc.br/etiquetagem/desenvolvimento/atividades-2012-2016/trabalho-1/pesquisas>. Acesso em: março de 2018.

DEUBLE, M.P.; DEAR, R.J. Mixedcomfortexpectations. Building and Enviroment, v. 54, p. 53-60, 2012.

INSTITUTO NACIONAL DE METROLOGIA, NORMALIZAÇÃO E QUALIDADE INDUSTRIAL -INMETRO. Portaria n.º 18, de 16 de janeiro de 2012. Regulamento Técnico daQualidade do Nível de Eficiência Energética de Edificações Residenciais. Rio deJaneiro, 2012. Disponível em: <http://www.pbeedifica.com.br/sites/default/files/projetos/etiquetagem/residencial/downloads/RTQR.pdf>. Acesso em: março de2018.

SORGATO, M.J.; MELO, A. P.; LAMBERTS, R. The effect of window opening ventilationcontrol on residential building energy consumption. Energy and Buildings, v. 133, p. 1-13, 2016.

Downloads

Publicado

2018-11-12

Como Citar

OLINGER, Marcelo Salles; MAZZAFERRO, Leonardo; MACHADO, Rayner Maurício e Silva; ELI, Letícia Gabriela; MELO, Ana Paula; FOSSATI, Michele; LAMBERTS, Roberto. DEFINIÇÃO DE ESCALAS DE EFICIÊNCIA ENERGÉTICA DA ENVOLTÓRIA EM EDIFICAÇÕES RESIDENCIAIS: ETIQUETAGEM BRASILEIRA. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 17., 2018. Anais [...]. Porto Alegre: ANTAC, 2018. p. 531–536. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1381. Acesso em: 19 jul. 2024.

Edição

Seção

(Inativa) Conforto Ambiental e Eficiência Energética

Artigos mais lidos pelo mesmo(s) autor(es)

1 2 3 > >> 

Artigos Semelhantes

<< < 17 18 19 20 21 22 23 24 25 26 > >> 

Você também pode iniciar uma pesquisa avançada por similaridade para este artigo.