ANÁLISE DAS PROPRIEDADES RADIATIVAS DE TRÊS TINTAS ACRÍLICAS E UMA TINTA NATURAL APLICADAS A TRÊS SUBSTRATOS

Authors

  • Carolina Rodrigues Dal Soglio
  • Bruna Just Meller
  • Marcelo Salles Olinger
  • Saulo Güths
  • Deivis Luis Marinoski
  • Martin Ordenes Mizgier

DOI:

https://doi.org/10.46421/entac.v17i1.1456

Keywords:

Building energy efficiency, Thermal properties, Solar reflectance, Natural paint

Abstract

The radiative properties of the envelope surfaces have a significant impact in the building's thermal performance. In the present study, thermal properties (emittance and reflectance of solar radiation) of one natural paint and four conventional paints were measured. The paints were applied on three substrates: metal, ceramic and wood. The properties were verified through laboratory tests. The solar reflectance measures were performed using a reflectometer and a spectrophotometer UV-Vis-NIR, according to the ASTM standards C1549-09 and E903-12, respectively. The portable emissometer was used for thermal emittance measurements, according to the ASTM standard C1371-15. The results show that the difference between the reflectance values measured by the equipments is up to 6%. The influence of the substrates was higher for the natural paint samples, presenting a relative variation of 6%. It was concluded that the reflectance of the natural paint throughout the different wavelengths behaves differently from the conventional paints. The natural paint showed higher reflectance for UV and IR, despite the relatively lower values of reflectance for waves in the visible spectrum.

References

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15220-2: VersãoCorrigida: 2008. Desempenho térmico de edificações Parte 2: Métodos de cálculoda transmitância térmica, da capacidade térmica, do atraso térmico e do fatorsolar de elementos e componentes de edificações. Rio de Janeiro, 2005.

______. NBR 15575-1: Edifícios habitacionais - Desempenho: parte 1: Requisitos gerais,in, Associação Brasileira de Normas Técnicas, Rio de Janeiro, 2013.

AMERICAN SOCIETY FOR TESTING AND MATERIALS. ASTM C1549-09: Standard TestMethod for Determination of Solar Reflectance Near Ambient Temperature Using aPortable Solar Reflectometer, 2014.

______. ASTM C1371 15: Standard Test Method for Determination of Emittance ofMaterials Near Room Temperature Using Portable Emissometers. 2015.

______.ASTM E903-12: Standard Test Method for Solar Absorptance, Reflectance, andTransmittance of Materials Using Integrating Spheres, 2012.

LAMBERTS, Roberto; DUTRA, L; PEREIRA Fernando. O. R. Eficiência Energética naArquitetura (3ª EDIÇÃO). Editora: ELETROBRAS/PROCEL. 2014, 365 p.

MARINOSKI, Deivis L. et al. Análise comparativa de valores de refletância solar desuperfícies opacas utilizando diferentes equipamentos de medição em laboratório.

In: ENCONTRO NACIONAL E LATINO-AMERICANO DE CONFORTO NO AMBIENTECONSTRUÍDO, XII e VIII, 2013, Brasília. Anais... Brasília: Associação Nacional deTecnologia do Ambiente Construído, 2013.

PEREIRA, Cláudia Donald. Influência da refletância e da emitância de superfíciesexternas no desempenho térmico de edificações. 2014. 207 f. Tese (Doutorado) -Programa de Pós-graduação em Engenharia Civil, Universidade Federal de SantaCatarina, Florianópolis, 2014.

Published

2018-11-12

How to Cite

DAL SOGLIO, Carolina Rodrigues; MELLER, Bruna Just; OLINGER, Marcelo Salles; GÜTHS, Saulo; MARINOSKI, Deivis Luis; MIZGIER, Martin Ordenes. ANÁLISE DAS PROPRIEDADES RADIATIVAS DE TRÊS TINTAS ACRÍLICAS E UMA TINTA NATURAL APLICADAS A TRÊS SUBSTRATOS. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 17., 2018. Anais [...]. Porto Alegre: ANTAC, 2018. p. 1140–1148. DOI: 10.46421/entac.v17i1.1456. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1456. Acesso em: 23 nov. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Most read articles by the same author(s)

1 2 > >> 

Similar Articles

<< < 1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.