Analysis of the sensitivity of the hygrothermal behaviour of a wall to different concrete hygrothermal characteristics

Authors

DOI:

https://doi.org/10.46421/entac.v19i1.2038

Keywords:

Hygrothermal behaviour, concrete, mould, computational simulation

Abstract

We analysed the sensitivity of the hygrothermal behaviour of a wall to the use of four datasets of hygrothermal characteristics of concrete available in the WUFI-Pro software database. Selected data have the same order of magnitude of specific mass and thermal conductivity, but different hygrothermal characteristics. A ground floor dwelling was considered, both unoccupied and occupied with natural ventilation. The results show the determining effect of hygrothermal characteristics on the wall moisture content, internal surface relative humidity and surface mould proliferation, thereby indicating the importance of measuring experimentally such characteristics for Brazilian materials.

Author Biographies

Adriana Camargo de Brito, Instituto de Pesquisas Tecnológicas do Estado de São Paulo

Doutorado em Engenharia Mecânica pela Universidade de São Paulo. Pesquisadora do Instituto de Pesquisas Tecnológicas do Estado de São Paulo.

Fernanda Belizario-Silva, Instituto de Pesquisas Tecnológicas do Estado de São Paulo

Doutora em Engenharia Civil pela Universidade de São Paulo. Pesquisadora do Instituto de Pesquisas Tecnológicas do Estado de São Paulo.

References

AFONSO, Thiago Martin. Desempenho higrotérmico de edificações e procedimentos para previsão de ocorrência de bolores em ambientes internos: estudo de caso de habitações construídas com paredes de concreto. Dissertação (Mestrado). Instituto de Pesquisas Tecnológicas, São Paulo, 2018.

AMERICAN NATIONAL STANDARDS INSTITUTE; AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS. ANSI/ASHRAE Standard 160 - Criteria for Moisture-Control Design Analysis in Buildings. 2016.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15220: Desempenho Térmico de Edificações. Rio de Janeiro, 2008.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15575: Edificações habitacionais - Desempenho. Rio de Janeiro, 2021.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 16401: Instalações de ar condicionado – Sistemas Centrais e Unitários. Rio de Janeiro, 2008.

BOMBERG, M. T.; SHIRTLIFFE, C. J. Hygrothermal characteristics of materials and components used in building enclosures. In: TRECHSEL, H. R.; BOMBERG, M. T. (eds.). Moisture Control in Buildings: The Key Factor in Mold Prevention. 2 ed. West Conshohocken: ASTM International, 2009. p. 16–36.

COMITÉ EUROPÉEN DE NORMALISATION. EN 15026 - Hygrothermal performance of building components and building elements - Assessment of moisture transfer by numerical simulation. Brussels, 2007.

DEUTSCHES INSTITUT FÜR NORMUNG. DIN 4108-3 - Wärmeschutz und Energie-Einsparung in Gebäuden - Teil 3: Klimabedingter Feuchteschutz - Anforderungen, Berechnungsverfahren und Hinweise für Planung und Ausführung. Berlim, 2018.

KÜNZEL, H. Simultaneous heat and moisture transport in Building components: one- and two-dimensional calculation using simple parameters. Tese (Doutorado). Fraunhofer Institute for Building Physics, Holzkirchen, 1995.

NASCIMENTO, M. L. M.; BAUER, E.; DE SOUZA, J. S.; ZANONI, V. A. G. Wind-driven rain incidence parameters obtained by hygrothermal simulation. Journal of Building Pathology and Rehabilitation, v. 1, n. 1, p. 5, 2016.

SANTOS, Alexandre Cordeiro. Avaliação do desempenho potencial de duas soluções de revestimentos argamassados em função do risco de formação de fungos emboloradores no interior de edificações na cidade de São Paulo. Dissertação (Mestrado). Instituto de Pesquisas Tecnológicas, São Paulo, 2019.

SEDLBAUER, K. Prediction of Mould Fungus Formation on the Surface of and Inside Building Components. Tese (Doutorado). Fraunhofer Institute for Building Physics, Holzkirchen, 2001.

SISTEMA NACIONAL DE AVALIAÇÕES TÉCNICAS. Diretrizes para a Avaliação de Produtos. Diretriz SINAT 001. Diretriz para Avaliação Técnica de paredes estruturais de concreto moldadas no local (Concreto Leve ou Concreto Reforçado com Fibra de Vidro). SINAT: Brasília, 2017.

VIITANEN, H.; KRUS, M.; OJANEN, T.; EITNER, V.; ZIRKELBACH, D. Mold Risk Classification Based on Comparative Evaluation of Two Established Growth Models. Energy Procedia, v. 78, p. 1425–1430, 2015.

ZANONI, Vanda Alice Garcia; DANTAS, André Luís de Faria; NUNES, Layane Soares; RIOS, Rafael Barbosa. Estudo higrotérmico na autoconstrução: simulação computacional e medições em campo. Ambiente Construído, v. 20, n. 3, p. 109–120, 2020

ZANONI, Vanda Alice Garcia; SANCHEZ, José Manoel Morales; BAUER, Elton. Métodos para quantificação de chuva dirigida incidente nas fachadas das edificações. PARC Pesquisa em Arquitetura e Construção, v. 9, n. 2, p. 122–132, 2018.

Published

2022-11-07

How to Cite

BRITO, Adriana Camargo de; BELIZARIO-SILVA, Fernanda. Analysis of the sensitivity of the hygrothermal behaviour of a wall to different concrete hygrothermal characteristics. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 19., 2022. Anais [...]. Porto Alegre: ANTAC, 2022. p. 1–14. DOI: 10.46421/entac.v19i1.2038. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/2038. Acesso em: 23 nov. 2024.

Issue

Section

(Inativa) Tecnologias de Sistemas e Processos Construtivos

Similar Articles

<< < 1 2 3 4 5 6 7 8 9 10 > >> 