Influence of solar control glass absorption on energy consumption for air conditioning in an office building

Authors

DOI:

https://doi.org/10.46421/entac.v19i1.2140

Keywords:

Solar control glasses. Optical properties. Absorption. Ar-conditioning consumption.

Abstract

The study evaluates the influence of solar control glass absorption on air-conditioned consumption for a commercial building by comparing glasses with equivalent solar heat gain coefficient or solar transmitance. The evaluations were conducted through computer simulation in the EnergyPlus software for Florianópolis (SC), Brasília (DF) and Rio de Janeiro (RJ). The results reveled differences in consumption with air conditioning from 3% to 18%. In all cases, buildings with higher electricity consumption had glass with greater solar absorption, characterizing it as a relevant parameter for the choice of glazing.

Author Biographies

Ana Carolina Zago, Universidade Federal de Santa Catarina

Architect and Urban Designer from the Federal University of Santa Catarina. Studying a master's degree at the Federal University of Santa Catarina (Florianópolis - SC, Brazil).

Bruna Just Meller, Universidade Federal de Santa Catarina

Master in Civil Engineering from the Federal University of Santa Catarina. Studying for a doctorate at the Federal University of Santa Catarina (Florianópolis - SC, Brazil).

Fernando Simon Westphal, Universidade Federal de Santa Catarina,Universidade Federal de Santa Catarina

Doctorate degree in Civil Engineering from the Federal University of Santa Catarina. Teacher at the Federal University of Santa Catarina (Florianópolis - SC, Brazil).

References

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR ISO 9050:2022: Vidros na construção civil — Determinação da transmissão de luz, transmissão direta solar, transmissão total de energia solar, transmissão ultravioleta e propriedades relacionadas ao vidro. Rio de Janeiro: ABNT, pág. 6-10, 2022.

CARMODY, John et al. Window Systems for High–Performance Buildings. Nova Iorque: W. W. Norton & Company, 2004. 400 p.

ENERGYPLUS, Weather file. Disponível em: https://energyplus.net/weather-region/south_america_wmo_region_3/BRA. Acesso em: 03 de ago. de 2022.

GASTINES, M.; PATTINI, A. E. Window energy efficiency in Argentina - Determining factors and energy savings strategies. Journal Of Cleaner Production, [S.L.], v. 247, p. 119104, fev. 2020. Elsevier BV. http://dx.doi.org/10.1016/j.jclepro.2019.119104.

IHM, P.; PARK, L.; KRARTI, M.; SEO, D. Impact of window selection on the energy performance of residential buildings in South Korea. Energy Policy, [S.L.], v. 44, p. 1-9, maio 2012. Elsevier BV. http://dx.doi.org/10.1016/j.enpol.2011.08.046.EASTMAN, C.; TEICHOLZ, P.; SACKS, R.; LISTON, K. BIM Handbook: a guide to building information modeling for owners, managers, designers, engineers and contractors. 2. ed. Nova Iorque: John Wiley & Sons, 2011.

PAGLIANO, L. et al. Improved methods for the calorimetric determination of the solar factor in outdoor test cell facilities. Energy And Buildings, [s.l.], v. 153, p.513–524, out. 2017. Elsevier BV. http://dx.doi.org/10.1016/j.enbuild.2017.07.028.

PINTO, Mônica, WESTPHAL, Fernando Simon. Energy Performance of Offices Buildings in Brazil using Insulated Glass Units. In: XVI IBPSA CONFERENCE, 16, 2019, Rome. Anais [...] . Rome: IBPSA, 2019. p. 4944-4951.

SACHT, H. M., BRAGANÇA, L., ALMEIDA, M., CARAM, R. Specification of Glazings for Façades Based on Spectrophotometric Characterization of Transmittance. Sustainability, v. 13, n. 10, p. 5437, 2021. https://doi.org/10.3390/su13105437.

SORGATO, Marcio José, MELO, Ana Paula, MARINOSKI, Deivis Luis, LAMBERTS, Roberto. Análise comparativa entre os resultados de simulações termoenergéticas de edificações sob diferentes condições de entrada das propriedades dos vidros. In: XV ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 15., 2014, Maceió. Anais [...] . Maceió: Entac, 2014. p. 23-32.

TSIKALOUDAKI, K.; LASKOS, K.; THEODOSIOU, Th.; BIKAS, D. Assessing cooling energy performance of windows for office buildings in the Mediterranean zone. Energy And Buildings, [S.L.], v. 49, p. 192-199, jun. 2012. Elsevier BV. http://dx.doi.org/10.1016/j.enbuild.2012.02.004.

YUAN, J., FARNHAM, C., EMURA, K. Effect of different reflection directional characteristics of building facades on outdoor thermal environment and indoor heat loads by CFD analysis. Urban Climate, [S.L.], v. 38, p. 100875, jul. 2021. Elsevier BV. http://dx.doi.org/10.1016/j.uclim.2021.100875.

Published

2022-11-07

How to Cite

ZAGO, Ana Carolina; MELLER, Bruna Just; WESTPHAL, Fernando Simon. Influence of solar control glass absorption on energy consumption for air conditioning in an office building. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 19., 2022. Anais [...]. Porto Alegre: ANTAC, 2022. p. 1–11. DOI: 10.46421/entac.v19i1.2140. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/2140. Acesso em: 25 nov. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Most read articles by the same author(s)

Similar Articles

<< < 9 10 11 12 13 14 15 16 17 18 > >> 

You may also start an advanced similarity search for this article.