AVALIAÇÃO PELO USUÁRIO DE UMA CÂMARA CLIMÁTICA: FOCO EM ASPECTOS DE CONFORTO AMBIENTAL

Authors

  • Rogerio Shibata Universidade Tecnológica Federal do Paraná
  • Livia Yu Iwamura Trevisan Universidade Tecnológica Federal do Paraná
  • André Luís de Sá Matias Universidade Tecnológica Federal do Paraná
  • Deize Lellys da Silva Universidade Tecnológica Federal do Paraná
  • Eduardo Lemes Schlemm Universidade Tecnológica Federal do Paraná
  • Eduardo Leite Krüger Universidade Tecnológica Federal do Paraná

DOI:

https://doi.org/10.46421/entac.v18i.742

Keywords:

Built Environment, Post-Occupancy Evaluation, Climate Chamber, Indoor Comfort, Building Performance, User Perception

Abstract

The research seeks to elaborate a diagnosis of positive and negative aspects, with a focus on indoor comfort, assessing user perception against thermal and luminous aspects reported in a semi-controlled test facility during two campaigns with distinct climatic conditions. The lab consists of two modules, office-like indoor environments, placed on top of rotating supports which allow testing different façade orientations. In the study 263 volunteer participants were invited to fill out two types of questionnaire. Firstly, a psychological test, which sought to assess differences in responsiveness related to environmental conditions. Secondly, a questionnaire sought to raise subjective aspects perceived by the volunteers in relation to different comfort aspects. From the analysis, it was verified to what extent comfort variables influenced the perception of the built environment as well as scores obtained in the psychological test, with more significant results found in the summer campaign.

References

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 16401 - Instalações de ar condicionado: sistemas centrais e unitários. São Paulo: ABNT, 2008.

______. NBR ISO/CIE 8995 – Iluminação de ambientes de trabalho, Parte 1: Interior. São Paulo: ABNT, 2013.

ANSI/ASHRAE. AMERICAN NATIONAL STANDARDS INSTITUTE; AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS. Standard 55-2017: Thermal Environmental Conditions for Human Occupancy. Atlanta. 2017.

BERKEBILE, B. (2017). REGENERATIVE COMPACT CITIES. Urban acupuncture and human purposed design. In: ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, 14., 2017. Balneário Camboriú, SC. Anais [...]. Porto Alegre: ANTAC, 2017.

BOCCALANDRO, E. R. Coleção G-38: Teste Não Verbal de Inteligência. São Paulo: Vetor, 2003.

CARVALHAIS, C. A. A. Contribuição para o estudo da tolerância humana a ambientes térmicos extremos: ensaios de validação de câmara climática. Dissertação (Programa de Pós-Graduação em Engenharia de Segurança e Higiene Ocupacionais), Faculdade de Engenharia da Universidade do Porto. Portugal. 2011.

ISO. 7730 – Ergonomics of the thermal environment: analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. ISO. Genebra. 2005.

KOWALTOWSKI, D. C. C. K. et al. Reflexão sobre metodologias de projeto arquitetônico.

Ambiente Construído, Porto Alegre, v. 6, n. 2, p. 07-19, abr/jun 2006.

KOWALTOWSKI, D. Prefácio. In: FABRICIO, M. M.; ORNSTEIN, S. W. Qualidade no projeto de edifícios. São Carlos: RiMa, 2010.

ORNSTEIN, S. W. Post Occupancy Evaluation in Brazil. In: ORGANISATION FOR ECONOMIC COOPERATION AND DEVELOPMENT (Eds). Evaluanting Quality in Educational Facilities. Paris: OECD. 2005. p. 135-143.

PREISER, W. F. E.; WHITE, E.; RABINOWITZ, H. Post-Occupancy Evaluation. reimpressão. ed. [S.l.]: Routledge, 2015.

PRISMATIC. Aplicativo Hue Pro. Hue Pro, 2016. Disponivel em: <http://hueproapp.com>. Acesso em: 20 ago 2018.

SCHIAVON, S. et al. Thermal comfort, perceived air quality, and cognitive performance when personally controlled air movement is used by tropically acclimatized persons. Indoor air, p. 1-13, 2016.

SHIBATA, Rogerio. Avaliação pelo usuário da Câmara Bioclimática de Baixo Custo: Foco em aspectos de conforto ambiental. Dissertação (Mestrado) - ) - Programa de Pós-Graduação em Engenharia Civil, Universidade Tecnológica Federal do Paraná. Curitiba, 2020.

TREVISAN, L. Y. I. Concepção, construção e verificação da aplicabilidade de uma Câmara Bioclimática de Baixo Custo em estudos de conforto ambiental. Tese (Doutorado) - Programa de Pós-Graduação em Engenharia Civil, Universidade Tecnológica Federal do Paraná. Curitiba. 2019.

VILLA, S.; ORNSTEIN, S. W.. Projetar apartamentos com vistas à qualidade arquitetônica a partir dos resultados da Avaliação Pós-Ocupação (APO). Gestão & Tecnologia de Projetos, v.

5, n. 2, p. 35-60, 2010YANG, Y. et al. A study of adaptive thermal comfort in a well-controlles climate chamber.

Applied Thermal Engineering, 2014.

Published

2020-11-04

How to Cite

SHIBATA, Rogerio; TREVISAN, Livia Yu Iwamura; MATIAS, André Luís de Sá; SILVA, Deize Lellys da; SCHLEMM, Eduardo Lemes; KRÜGER, Eduardo Leite. AVALIAÇÃO PELO USUÁRIO DE UMA CÂMARA CLIMÁTICA: FOCO EM ASPECTOS DE CONFORTO AMBIENTAL. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.742. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/742. Acesso em: 3 dec. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Most read articles by the same author(s)

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.