Abstract

The concept of zero energy applied to military buildings is an excellent option to meet the energy demands of the military environment and to reduce the high consumption of buildings. The buildings of the Brazilian Army must be classified with level A in the National Energy Conservation Label. Distributed generation has grown in Brazil, with a large share of photovoltaic systems. The objective of this work was to evaluate the design of a military building for the Brazilian Army to transform it into a Zero Energy Building (EEZ) with photovoltaic systems to compensate for the reduced energy demand. The computational simulation method of INIC was applied in DesignBuilder and the generation estimates of the photovoltaic system were obtained using SAM (System Advisory Model). The building project was classified as level A, with a 59.5% reduction in consumption compared to the reference building. The analyzed photovoltaic systems (c-Si and CdTe) met the annual demand with productivity values of 1,571 kWh/kW and 1,586 kWh/kW and Performance Ratio (PR) of 0.79 and 0.80, respectively. The optimization analysis of the orientation of the building resulted in a small impact on energy consumption; however, in photovoltaic generation the impact was considerable, since in the optimized orientation the generation was 11.3% greater.

References

ANEEL. Geração Distribuída. Microsoft Power BI. Disponível em: https://app.powerbi.com/ Acesso em: 2 jul. 2020.

______. Resolução Normativa No 482, de 17 de abril de 2012. 2012.

BAVARESCO, M., MAZZAFERRO, L., MELO, A. P., LAMBERTS, R. "Análise da precisão de um metamodelo para a avaliação da envoltória de acordo com o regulamento brasileiro de eficiência energética em edificações". 2017. Anais [...] Balneário Camboriú, [s.n.], 2017.

BRAGA, M., CAMPOS, R. A., DO NASCIMENTO, L. R., RUTHER, R., SANTOS, E. M. "Avaliação de desempenho de diferentes tecnologias fotovoltaicas em Irecê, BA". 2018. Anais [...] Gramado, [s.n.], 2018.

BRASIL. Ministério do Planejamento, Orçamento e Gestão (MPOG). Instrução Normativa No 2, de 4 de junho de 2014. 2014CO/ 3° GPT E. Planta de Lay-Out (Planta Humanizada), Estudo de Insolação e Perspectivas -Construção da Companhia de Comando e Apoio (CCAp). Campo Grande, MS: Exército Brasileiro. Diretoria de Obras Militares, 2017CRAWLEY, Drury; TORCELLINI, Paul; PLESS, Shanti. Getting to Net Zero Energy Buildings. ASHRAE Journal, n. September, 2009. Disponível em: <https://www.nrel.gov/docs/fy09osti/46382.pdf>.

FOSSATI, M., SCALCO, V. A., LINCZUK, V. C. C., LAMBERTS, R. "Building energy efficiency: An overview of the Brazilian residential labeling scheme", Renewable and Sustainable Energy Reviews, v. 65, p. 1216–1231, 2016. DOI: 10.1016/j.rser.2016.06.048.

FRAUNHOFER. Photovoltaics Report©Fraunhofer ISE: Photovoltaics Report. ©Fraunhofer ISE: Photovoltaics Report, v. 2013, n. March, p. 1–18, 2019.

IEA. Global Status Report for Buildings and Construction 2019. Paris, França: International Energy Agency. 2019INMETRO. Manual para Aplicação do RTQ-C. Rio de Janeiro, RJ, 2016_________. Portaria n° 17, de 16 de janeiro de 2012. 2012_________. Portaria no 248, de 10 de julho de 2018. 2018MELO, A. P., CÓSTOLA, D., LAMBERTS, R., HENSEN, J. L. M. "Assessing the accuracy of a simplified building energy simulation model using BESTEST: The case study of Brazilian regulation", Energy and Buildings, 2012. DOI: 10.1016/j.enbuild.2011.11.007.

MELO, A.P., CÓSTOLA, D., LAMBERTS, R.,HENSEN, J.L.M. "Desenvolvimento de um método para aprimorar a precisão do método prescritivo da etiquetagem PROCEL/INMETRO para edifícios comerciais", Encontro Nacional de Conforto no Ambiente Construído, 12., n. 2013, 2013.

RORIZ, M. Classificação de Climas do Brasil – Versão 3.0. Associação Nacional de Tecnologia do Ambiente Construído (ANTAC), p. 1–5, 2014.

SORGATO, M. J.; SCHNEIDER, K.; RÜTHER, R. Technical and economic evaluation of thin-film CdTe building-integrated photovoltaics (BIPV) replacing façade and rooftop materials in office buildings in a warm and sunny climate. Renewable Energy, v. 118, p. 84–98, 2018.

VERSAGE, R. S. Metamodelo para estimar a carga térmica de edificações condicionadas artificialmente. 2015. Tese (Doutorado em Engenharia Civil). UFSC, Florianópolis.

YAMAKAWA, M. A., WESTPHAL, F. S. "Influência do percentual de abertura nas fachadas e do fator solar dos vidros na etiquetagem do PROCEL/INMETRO: método prescritivo x simulação".

2011. Anais [...] Búzios, [s.n.], 2011.

Published

2020-11-04

How to Cite

NETO, Luiz Pereira da Silva; PIMENTEL, Breno Pontes; BARBOSA, Andréa Teresa Riccio; SORGATO, Marcio José. AVALIAÇÃO TÉCNICA DO POTENCIAL DE TRANSFORMAR UMA EDIFICAÇÃO MILITAR EM EDIFICAÇÃO DE ENERGIA ZERO. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.794. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/794. Acesso em: 18 jul. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Similar Articles

<< < 15 16 17 18 19 20 21 22 23 24 > >> 

You may also start an advanced similarity search for this article.