Determinação do fator solar de vidros por meio de medições laboratoriais, simulações computacionais e cálculos normatizados

Authors

DOI:

https://doi.org/10.46421/encac.v17i1.4161

Keywords:

Solar Heat Gain Coefficient, Laboratory measurements, Computational simulation

Abstract

Solar Heat Gain Coefficient (SHGC) is a thermal property of glass and transparent elements, defined as the ratio between the amount of solar energy that passes through the glass by the amount of solar energy that reaches it. SHGC can be determined by means of mathematical models, computer simulations, or field and laboratory measurements. This paper compares the SHGC obtained by means of laboratory measurements, using the PoWEM equipment, with values determined by using the WINDOW software and calculated according to ISO 9050 standard. Two solar control glasses and one clear glass, used as a reference, were selected. The SHGCs obtained by means of laboratory measurements were lower than the other methods due to solar simulator and equipment's limitations. Despite it, there was a good approximation of the behavior of the glasses regarding the increase in air velocity. The heat transfer coefficient on exterior surface is fixed, so the SHGC obtained for each glass based on ISO 9050 remains the same, regardless the air velocity. The SHGC results based on ISO 9050 were similar to those measured by PoWEM under conditions of higher air velocities.

Author Biographies

Bruna Just Meller, Universidade Federal de Santa Catarina

Mestre em Engenharia Civil pela Universidade Federal de Santa Catarina. Doutoranda em Engenharia Civil na Universidade Federal de Santa Catarina (Florianópolis - SC, Brasil).

Deivis Luis Marinoski, Universidade Federal de Santa Catarina

Doutor em Engenharia Civil pela Universidade Federal de Santa Catarina. Professor Adjunto na Universidade Federal de Santa Catarina (Florianópolis - SC, Brasil).

Saulo Guths, Universidade Federal de Santa Catarina

Doutor em Ciências Térmicas pela Université D'artois. Professor Adjunto na Universidade Federal de Santa Catarina (Florianópolis - SC, Brasil).

Enedir Ghisi, Universidade Federal de Santa Catarina

Doutor em Engenharia Civil pela University of Leeds. Professor titular na Universidade Federal de Santa Catarina (Florianópolis - SC, Brasil).

References

BAUMAN, F. S.; PLACE, J. W.; THORNTON, J.; AND HOWARD, T. C. An Integrating Window Pyranometer for Beam Daylighting Measurements in Scale–Model Buildings. ASHRAE Transactions, v. 92 (part 1A), p. 486–493, 1985.

CARMODY, John; SELKOWITZ, Stephen; LEE, Eleanor S.; ARASTEH, Dariush. Window Systems for High–Performance Buildings. Nova Iorque: W. W. Norton & Company, 2004. 400 p.

COLLINS, M. R. HARRISON, S. J. Calorimetric Measurement of the Inward-Flowing Fraction of Absorbed Solar Radiation in Venetian Blinds. ASHRAE Transactions, 1999.

GÜTHS, S. US – Brazil Collaborative Work. Florianópolis: 2015.

GÜTHS, Saulo et al. Medidor Portátil de Fator Solar. Registro de Patente. Número do registro: BR10201901224, Instituição de registro: INPI - Instituto Nacional da Propriedade Industrial. 14 jun. 2019.

HARRISON, S. J. VAN WONDEREN, S. J. Evaluation of solar heat gain coefficient for solar-control glazings and shading devices. ASHRAE Transactions, 1998.

HARRISON, S. J.; COLLINS, M. R. Queen’s University Solar Calorimeter: design, calibration, and operating procedure. In: SOLAR ENERGY SOCIETY OF CANADA CONFERENCE, 1., 1999, Edmonton. Proceedings […]. Edmonton: Solar Energy Society of Canada, 1999. p. 1-6.

INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. ISO 15099: Thermal performance of windows, doors and shading devices – Detailed calculations. Geneva: ISO, 2003a.

_____. ISO 9050: Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors. Geneva: ISO, 2003b.

KLEMS, J. H.; SELKOWITZ, S. E. The Mobile Window Thermal Test Facility (MoWITT). In: CONFERENCE ON THE THERMAL PERFORMANCE OF THE EXTERIOR ENVELOPES OF BUILDINGS, 1., 1979, Orlando. Proceedings […]. Nova Iorque: ASHRAE/DOE, 1981. p. 930 – 941

KUHN, Tilmann E. Calorimetric determination of the solar heat gain coefficient g with steady-state laboratory measurements. Energy and Buildings, [S.L.], v. 84, p. 388-402, dez. 2014. Elsevier BV. http://dx.doi.org/10.1016/j.enbuild.2014.08.021.

LAMBERTS, Roberto; DUTRA, Luciano; PEREIRA, Fernando O. R. Eficiência Energética na Arquitetura. 3. ed. Rio de Janeiro: Eletrobras/PROCEL, 2014.

MACEDO, Catharina Cavalcante de. Análise do desempenho térmico e luminoso de sistemas de iluminação natural que utilizam a luz direta do sol. Florianópolis. 135 p. Dissertação (Mestrado) - Curso de Engenharia Civil, Universidade Federal de Santa Catarina, Florianópolis, 2002.

MARINOSKI, D. L.; LAMBERTS, R. Aplicação dos programas Window e Wis para modelagem de janelas com proteções solares. In: ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, 9., ENCONTRO LATINO AMERICANO DE CONFORTO NO AMBIENTE CONSTRUÍDO, 5., 2007, Ouro Preto. Anais [...]. Ouro Preto: ANTAC, 2007. p. 1123-1132.

MARINOSKI, D. L.; MILBRATZ, J. H.; LAMBERTS, R. Verificação de propriedades térmicas e ópticas de janelas através de simulação computacional. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 12., 2008, Fortaleza. Anais [...]. Fortaleza: ANTAC, 2008.

MARINOSKI, Deivis Luis. Aperfeiçoamento de um sistema de medição de ganho de calor solar através de aberturas. 2005. 124 f. Dissertação (Mestrado) - Curso de Engenharia Civil, Universidade Federal de Santa Catarina, Florianópolis, 2005.

MARINOSKI, Deivis Luis. Desenvolvimento de um calorímetro para determinação do fator solar de vidros e janelas. 2010. 298p. Tese (Doutorado) – Departamento de Engenharia Civil, Universidade Federal de Santa Catarina, Florianópolis, 2010.

MELLER, B. J.; MARINOSKI, D. L.; GÜTHS, S. Influência da velocidade do vento no Fator Solar de vidros de controle solar monolíticos e laminados. In: XV ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO E XI ENCONTRO LATINO-AMERICANO DE CONFORTO NO AMBIENTE CONSTRUÍDO, 2019, João Pessoa. Anais [...]. Porto Alegre: ANTAC, 2019. p. 1892-1899.

PAGLIANO, Lorenzo; CATTARIN, Giulio; CAUSONE, Francesco; KINDINIS, Andrea. Improved methods for the calorimetric determination of the solar factor in outdoor test cell facilities. Energy and Buildings, [S.L.], v. 153, p. 513-524, out. 2017. Elsevier BV. http://dx.doi.org/10.1016/j.enbuild.2017.07.028.

PEREIRA, Fernando Oscar Ruttkay. Luminous and thermal performance of windows shading and sunlighting reflecting devices. 1992. 310p. Tese (Doutorado em Filosofia) - Building Science Unit, School of Architectural Studies, University of Sheffield. Sheffield. 1992.

VAN WONDEREN, Simon. Experimental Determination of Fenestration Solar Heat Gain Coefficient. 1995. 146 f. Dissertação (Mestrado em Engenharia Mecânica) – Queen’s University, Kingston (Canadá), 1995.

Published

2023-10-26

How to Cite

MELLER, Bruna Just; MARINOSKI, Deivis Luis; GUTHS, Saulo; GHISI, Enedir. Determinação do fator solar de vidros por meio de medições laboratoriais, simulações computacionais e cálculos normatizados. In: ENCONTRO NACIONAL DE CONFORTO NO AMBIENTE CONSTRUÍDO, 17., 2023. Anais [...]. [S. l.], 2023. p. 1–9. DOI: 10.46421/encac.v17i1.4161. Disponível em: https://eventos.antac.org.br/index.php/encac/article/view/4161. Acesso em: 24 nov. 2024.

Issue

Section

4. Desempenho Térmico do Ambiente Construído