AVALIAÇÃO ENERGÉTICA, TÉRMICA E LUMÍNICA DE DISPOSITIVOS DE SOMBREAMENTO EM ESCRITÓRIOS

Autores

  • Dayan de Loyola Garcia
  • Fernando Oscar Ruttkay Pereira

Palavras-chave:

Simulation, Roller-Shades, Energy-Efficiency, Thermal Performance, Daylighting

Resumo

This paper comes to explore some combinations s properties to balance heat gains, daylight admission, thermal comfort, visual discomfort and energy consumption. These variables were evaluated by EnergyPlus 8.8.0 simulations in a side-lit office model with location in two Brazilian cities with different climatic conditions. Results achieved poor reductions in temperature, but good reductions in cooling energy consumption and daylight glare for those devices that have high reflectance and low transmittance. In other hand, it was observed undesirable reductions in daylight availability and increase in lighting energy consumption.

Referências

INSTITUTO NACIONAL DE METROLOGIA NORMALIZAÇÃO E QUALIDADE INDUSTRIAL(INMETRO). Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Comerciais, de Serviço e Público (RTQ-C). Portaria n.

372/3013. Rio de Janeiro, 2013.

KONSTANTZOS, I.; TZEMPELIKOS, A. Daylight glare evaluation with the sun in the fieldof view through window shades. Building e. Environment. ed.113, 2017, p. 65 - 77MRS MÓVEIS, Móveis de Escritório. Persiana Rolô. Homepage da empresa. Rio deJaneiro, 2018. Disponível em: < http://www.mrsmoveis.com.br/persiana-rolo/ >.Acesso em: 20 mar. 2018.

RAMOS, G.; GHISI, E. Analysis of daylight calculated using the EnergyPlus programme.

Renewable and Sustainable Energy Reviews. ed.14, p. 1948-1958, 2010.

REINHART, C.; JAKUBIEC, A.; IBARRA, D. MIT Reference Office. 2013. Disponível em:<http://web.mit.edu/sustainabledesignlab/projects/ReferenceOffice/index.html>.Acesso em: 20 março. 2018.

REINHART, C.; JAKUBIEC, A.; IBARRA, D.; Definition of a reference office forstandardized evaluations of dynamic façade and lighting technologies. Proceedingsof BS2013: 13th Conference of International Building Performance SimulationAssociation, Chambéry, France, 2013.

RUPP, R. F. Dimensionamento de área de janela em edificações comerciais:integração da iluminação natural com a artificial e utilização de ventilação híbrida.

Dissertação de Mestrado em Engenharia Civil Universidade Federal de SantaCatarina, Florianópolis, 2011.

SHEN, H.; TZEMPELIKOS, A. Daylighting and energy analysis of private offices withautomated interior roller shades. Solar Energy. ed.86, 2012, pg. 681 704.

SINGH, R.; LAZARUS, I.J.; KISHORE, V.V.N. Effect of internal woven roller shade andglazing on the energy and daylighting performances of an office building in the coldclimate of Shillong. Applied Energy. ed.159, 2015, pg.317 333.

TZEMPELIKOS A.; CHAN, Y. C. Estimating detailed optical properties of window rollershades from basic available data and modeling implications on daylighting andvisual comfort. Energy e Buildings. n. 126, 2016, p. 396-407.

TZEMPELIKOS, A.; SHEN, H. Comparative control strategies for roller shades withrespect to daylighting and energy performance. Building and Environment. ed.67,2013, p. 179-192.

US Department of Energy, Energyplus Engineering Reference. The Reference toEnergyPlus Calculations, Lawrence Berkeley National Laboratory, 2017.

Downloads

Publicado

2018-11-12

Como Citar

GARCIA, Dayan de Loyola; PEREIRA, Fernando Oscar Ruttkay. AVALIAÇÃO ENERGÉTICA, TÉRMICA E LUMÍNICA DE DISPOSITIVOS DE SOMBREAMENTO EM ESCRITÓRIOS. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 17., 2018. Anais [...]. Porto Alegre: ANTAC, 2018. p. 825–832. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1414. Acesso em: 30 jun. 2024.

Edição

Seção

(Inativa) Conforto Ambiental e Eficiência Energética

Artigos Semelhantes

<< < 1 2 3 4 5 6 7 8 9 10 > >> 

Você também pode iniciar uma pesquisa avançada por similaridade para este artigo.