INFLUÊNCIA DA ÁREA DE ESTRUTURA EM AÇO EXPOSTA NO DESEMPENHO TÉRMICO DE EDIFICAÇÕES

Autores

  • Lucas Fonseca Caetano
  • Henor Artur de Souza
  • Adriano Pinto Gomes

DOI:

https://doi.org/10.46421/entac.v17i1.1417

Palavras-chave:

Thermal performance, Steel structure, Thermal bridge, Natural ventilation, Thermal load

Resumo

When a material with high thermal conductivity, such as steel, is placed in parallel with a less conductive material, most of the heat transfer occurs through the steel by conduction, characterizing an effect known as thermal bridging through the steel profile or exposed structure. The thermal bridge reduces the thermal resistance of the closings and increases energy costs for environmental heating or cooling. Taking into account these considerations, this paper aims to evaluate the thermal performance of naturally ventilated and artificially conditioned environments by means of computational simulations using the EnergyPlus program. The results show that there was an increase of about 12,5% in the building energy consumption considering a typical summer design day as a function of the exposed steel area of the building structure. There was a maximum increase of 10,6% in the environment total thermal cooling load, evidencing that the larger the exposed steel area in the building closed system, the greater the effect caused by this thermal bridge.

Referências

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15220: Desempenhotérmico de edificações. Rio de Janeiro, 2005.

______. NBR 15575: Edificações habitacionais Desempenho. Rio de Janeiro, 2013.

EDIFÍCIO Acal. São Paulo, SP, 1974. Disponível em: <http://www.vitruvius.com.br/>.Acesso em: 04 mai. 2016.

Gomes, A. P.; Souza, H. A. A influência da estrutura de aço aparente no consumode energia e na carga térmica para o resfriamento em ambientes escolares. RevistaSul-Americana de Engenharia Estrutural, Passo Fundo, v. 10, n. 3, p. 5-23, jul./dez.2013.

MARTIN, K.; CAMPOS-CELADOR, A.; ESCUDERO, C.; GÓMEZ, I.; SALA, J. M. Analysis ofa thermal bridge in a guarded hot box testing facility. Energy and Buildings, n. 50, p.139-149, 2012.

Sierra, F.; Bai, J.; Maksoud, T. Impact of the simplification of the methodology used toasses the thermal bridge of the head of an opening. Energy and Buildings, n. 87, p.342-347, 2015.

Theodosiou, T. G.; Papadopoulos, A. M. The impact of thermal bridges on the energydemand of buildings with double brick wall constructions. Energy and Buildings, n. 40,p. 2083-2089, 2008.

Downloads

Publicado

2018-11-12

Como Citar

CAETANO, Lucas Fonseca; SOUZA, Henor Artur de; GOMES, Adriano Pinto. INFLUÊNCIA DA ÁREA DE ESTRUTURA EM AÇO EXPOSTA NO DESEMPENHO TÉRMICO DE EDIFICAÇÕES. In: ENCONTRO NACIONAL DE TECNOLOGIA DO AMBIENTE CONSTRUÍDO, 17., 2018. Anais [...]. Porto Alegre: ANTAC, 2018. p. 850–857. DOI: 10.46421/entac.v17i1.1417. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1417. Acesso em: 25 dez. 2024.

Edição

Seção

(Inativa) Conforto Ambiental e Eficiência Energética

Artigos Semelhantes

<< < 69 70 71 72 73 74 75 76 77 78 > >> 

Você também pode iniciar uma pesquisa avançada por similaridade para este artigo.