ANÁLISE DO DESEMPENHO HIGROTÉRMICO DE PAREDES DE FACHADA POR MEIO DE SIMULAÇÃO COMPUTACIONAL ESTUDOS DE CASO

Authors

  • Alexandre Cordeiro Santos
  • Luciana Alves Oliveira
  • Osmar Hamilton Becere
  • Julio Cesar Sabadini Souza

DOI:

https://doi.org/10.46421/entac.v17i1.1708

Keywords:

Moisture, Facade, Hygrothermal assessment

Abstract

The moisture can make the building environment unhealthy and affecting the user's health and the durability of building and furniture. Current Brazilian technical standards are still insufficient to deal with this issue and one of the alternatives is the computer simulation, which, although limited, can be useful. The aim of this manuscript is to show the results of the hygrothermal assessment (temperature and moisture content) of the two facades section of two different buildings, which is part of the case studies. This assessment was done through computer simulation with WUFI-Pro software. The follow activities were done: Bibliographical review, laboratory tests for collecting the hygrothermal characteristics of the building materials used in the facades of the case studies and collected of the temperature and moisture in the apartments (housing) of the case studies. The use of a computer simulation to evaluate the moisture transfer through a wall is feasible. The data obtained show that the percentage of moisture occurrence in the case studies is consistent with the results obtained in the simulation.

References

ANSI/ASHRAE - American National Standards Institute & American Society ofHeating, Refrigerating and Air- Conditioning Engineers. ANSI/ASHRAE 160 -Criteria for Moisture-Control Design Analysis in Buildings. Atlanta, 2016.

ABNT NBR 13280:2005 Argamassa para assentamento e revestimento deparedes e tetos Determinação da densidade de massa no estadoendurecido (Procedimento CT-OBRAS-LMCC-R-PE-005).

AMERICAN SOCIETY FOR TESTING. ASTM D4404 Determination of Pore Volumeand Pore Volume Distribution of Soil and Rock by Mercury IntrusionPorosimetry. Philadelphia, 2010.

EN ISO 12572: 2001, Higrothermal Performance of Buildings Materials andProducts: Determination of Water Vapour Transmission Properties(Procedimento CT-OBRAS-LMCC-R-PE-035).

EN ISO 15148: 2002, Higrothermal Performance of Buildings Materials andProducts: Determination of Water Absorption Coefficient by PartialImmersion(Procedimento CT-OBRAS-LMCC-R-PE-036.EPW-ANTAC (RORIZ, 2012).

FREITAS, V. P.; PINTO, P. S. Permeabilidade ao vapor de materiais deconstrução condensações internas. 2.ed. Nota de informação técnica - NIT002 do Laboratório de Física das Construções - LFC da Faculdade deEngenharia da Universidade do Porto. Porto, 2000.

KÜNZEL, H. M. Simultaneous Heat and Moisture Transport in BuildingComponents. One and two dimensional calculation using simple parameters.

Fraunhofer IRB Verlag Stuttgart, 1995.

. Acesso em 19.fev.2018. 65p.

MENDES, N. Modelos para Previsão da Transferência de Calor e de Umidadeem Elementos Porosos de Edificações. Tese (Doutorado). UniversidadeFederal de Santa Catarina. Florianópolis, 1997.

MENDES, N.; OLIVEIRA, R. C. L. F.; Santos, G. H. . Domus. 2003. Patente: Modelode Utilidade. Número do registro: 05270-5, data de depósito: 01/07/2003,título: "Domus" , 2003a.

TRECHSEL, H.R. (Ed.). Moisture Control in Buildings: The Key Factor in MoldPrevention. 2. ed. Philadelphia: Trechsel, Trechsel R, 2009. 485 p.

Published

2018-11-12

How to Cite

SANTOS, Alexandre Cordeiro; OLIVEIRA, Luciana Alves; BECERE, Osmar Hamilton; SOUZA, Julio Cesar Sabadini. ANÁLISE DO DESEMPENHO HIGROTÉRMICO DE PAREDES DE FACHADA POR MEIO DE SIMULAÇÃO COMPUTACIONAL ESTUDOS DE CASO. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 17., 2018. Anais [...]. Porto Alegre: ANTAC, 2018. p. 2918–2926. DOI: 10.46421/entac.v17i1.1708. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1708. Acesso em: 22 nov. 2024.