PROPOSTA DE CLASSIFICAÇÃO CLIMÁTICA DIÁRIA PARA AVALIAÇÃO DE DESEMPENHO EM MEDIÇÕES DE CAMPO

Authors

  • Rafael Rios
  • Vanda Zanoni

DOI:

https://doi.org/10.46421/entac.v17i1.1711

Keywords:

Climate Classification, Daily Weather Classification, Performance Evaluation

Abstract

For building s studies, the classification of climate conditions are useful tools for design studies, performance evaluation. However, for a daily approach, such as building's surveys, there is a lack of methods for climate classification, which difficult the definition of test's parameters. So, based on the analysis of Typical Meteorological Year- TMY files from different Brazilian cities, this paper presents a method for daily weather classification. This method allows the daily weather characterization during building's survey, and also contributes for the definition of on field test's parameters.

References

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15220-3: DesempenhoTérmico de Edificações - Parte 3: Zoneamento Bioclimático Brasileiro e DiretrizesConstrutivas para Habitações Unifamiliares de Interesse Social. Rio de Janeiro, 2005.

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15575-1: Edificaçõeshabitacionais Desempenho Parte 1: Requisitos gerais. Rio de Janeiro, 2013.

AKUTSU, M.; VITTORINO, F. Proposta de procedimentos para o tratamento de dadosclimáticos. In: Encontro Nacional de Normalização Ligada ao Uso Racional deEnergia e ao Conforto Ambiental em Edificações, p. 213-226, Florianópolis, 1991.

ALVARES, C.; STAPE, J.; SENTELHAS, P.; GONCALVES, J.; SPAROVEK, G.

climate classification map for Brazil. Meteorologische Zeitschrift, v. 22, n. 6. p.711 728.

Gebrüder Borntraeger, Stuttgart, 2013.

BRITO, A. C.; SALES, E. M.; VITTORINO, F.; AQUILINO, M.; AKUTSU, M. Necessidade deRevisão dos Métodos de Avaliação do Desempenho Térmico de Edificações noÂmbito da Norma NBR 15575 e do SiNAT. In: Avaliação de Desempenho deTecnologias Construtivas Inovadoras. ANTAC, 2017.

BS ISO - BRITISH STANDARD INSTITUTION. BS ISO 15686-7: Buildings and constructedassets Service life planning Part 7: Performance evaluation for feedback ofservice life data from practice. London, 2006.

HAAGENRUD, S. Factors Causing Degradation: Part II. In: Guide and Bibliography toService Life and Durability Research for Buildings and Components. CIB Publication295, p.1.2-104. CIB, Rotterdam, 2004.

LAMBERTS, R.; DUTRA, L.; PEREIRA, F. Eficiência Energética na Arquitetura. 3.ed. Rio deJaneiro: Eletrobras Procel Edifica, 2013.

RORIZ, M. Arquivos Climáticos de Municípios Brasileiros. ANTAC. São Carlos-SP, 2012.

WYPYCH, G. Handbook of Material Weathering. 5. ed. Toronto, 2013.

ZANONI, V. Influência dos agentes climáticos de degradação no comportamentohigrotérmico de fachadas em Brasília. Tese de Doutorado em Arquitetura eUrbanismo. Universidade de Brasília, Brasil. 2015.

Published

2018-11-12

How to Cite

RIOS, Rafael; ZANONI, Vanda. PROPOSTA DE CLASSIFICAÇÃO CLIMÁTICA DIÁRIA PARA AVALIAÇÃO DE DESEMPENHO EM MEDIÇÕES DE CAMPO. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 17., 2018. Anais [...]. Porto Alegre: ANTAC, 2018. p. 2942–2950. DOI: 10.46421/entac.v17i1.1711. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1711. Acesso em: 24 nov. 2024.

Issue

Section

(Inativa) Tecnologias de Sistemas e Processos Construtivos

Similar Articles

<< < 68 69 70 71 72 73 

You may also start an advanced similarity search for this article.