DIAGNÓSTICO DE FALHA NO SISTEMA PREDIAL DE ÁGUAS PLUVIAIS DE UM PRÉDIO HISTÓRICO ATRAVÉS DO USO DE TERMOGRAFIA DE INFRAVERMELHO
DOI:
https://doi.org/10.46421/entac.v17i1.1787Keywords:
Thermography, Historic Buildings, Rainwater System, Pathological ManifestationAbstract
The heritage buildings have historical and cultural value within the context where they are inserted, and because they have been built with specific techniques and materials, according to their time, should be analyzed with due care. Allied to this, these buildings usually present several pathological manifestations from different factors. In this context, this work aimed to diagnose the origin of infiltration moisture in the external vertical sealing system of a historic building. The method used for this evaluation involved the following steps: anamnesis, rain test, thermography and results analysis. In the anamnesis, it was identified that the infiltration occurred on rainy days and the higher the rainfall intensity, the greater the water intake through the SVVE. The tests were performed after several days without rain, ie the walls had no areas of moisture. The tests were carried out considering the watertightness of the pipes of the rainwater system and the gutters. Infrared thermography was used as a tool for performance evaluation. The results demonstrated that the failure occurred in the fence of the gutters and the used technique allowed the identification of the origin of the pathological manifestation without destructive interventions that compromised the historic building.
References
Acervo Do Setor De Patrimônio Histórico Da Universidade Federal do RioGrande do Sul, Base Digital. Consulta local em: 18/03/2018.
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15575: Edifícioshabitacionais de até cinco pavimentos - Desempenho. Rio de Janeiro: ABNT,2013.
AVDELIDIS, N. P.; MOROPOULOU, A. Emissivity considerations in buildingthermography. v. 35, p. 663 667, 2003.
BARREIRA, E. S. B. M. Aplicação da Termografia ao Estudo do ComportamentoHigrotérmico dos Edifícios. Dissertação submetida para satisfação parcial dosrequisitos do grau de Mestre em Construção de Edifícios: [s.n.].
BAUER, E.; LEAL, F. E. C. B. ARTIGO TÉCNICO 25 - Considerações Iniciais sobre aTermografia Aplicada à Inspeção de Fachadas. Disponível em:<http://materialsandmateriais.blogspot.com.br/2013/08/artigo-tecnico-25-consideracoes.html>.
GRINZATO, E.; BISON, P. G.; MARINETTI, S. Monitoring of ancient buildings by thethermal method. v. 3, p. 21 29, 2002.
RIO GRANDE DO SUL. Lei n° 11.525, de 15 de setembro de 2000. Gabinete deConsultoria Legislativa, Assembleia Legislativa. Porto Alegre, 2000. Disponívelem: <http://www.al.rs.gov.br/filerepository/repLegis/arquivos/11.525.pdf>.Acesso em: 18 mar. 2018.
SILVA, M. de N. B. da. Avaliação Quantitativa da Degradação e Vida Útil deRevestimentos de Fachada Aplicação ao Caso de Brasília/DF. Tese deDoutorado em Estruturas e Construção Civil, Faculdade de Tecnologia daUniversidade de Brasília, 2014.
TONIOLI, R. M. Cidade e universidade : arquitetura e configuração urbana doCampus Centro da UFRGS. Dissertação de Mestrado, Programa de Pesquisa ePós-Graduação em Arquitetura, Universidade Federal do Rio Grande do Sul,2014.