Thermal calibration of an existing institutional building

Authors

DOI:

https://doi.org/10.46421/entac.v19i1.1961

Keywords:

Uncertainty analysis, Whole-building performance simulation, Survey data, Model Validation

Abstract

Building performance simulation (BPS) exhibits an interplay of various physical parameters, only portraying limited building fundamental characteristics. Therefore, BPS calibration can increase simulation accuracy and better depict the physical space. We aimed to calibrate/validate an institutional building model in Viçosa-MG, testing parallel and serial uncertainty procedures. We conducted a manual/statistic hygrothermal calibration using surveyed indoor/outdoor air dry-bulb temperature (DBT) and relative humidity (RH). We evaluated site-specific weather files and compared simulation outputs and measured data using the Root Mean Square Error (RMSE). As a result, the validated model presented 0.56°C to 0.85°C DBT discrepancies and 3.10% to 5.90% RH differences. 

Author Biographies

Caio de Carvalho Lucarelli, Universidade Federal de Viçosa

Mestre em Arquitetura e Urbanismo pela Universidade Federal de Viçosa. Doutorando em Arquitetura e Urbanismo pela Universidade Federal de Viçosa

Matheus Menezes Oliveira, Universidade Federal de Viçosa

Mestre em Arquitetura e Urbanismo pela Universidade Federal de Viçosa. Doutorando em Arquitetura e Urbanismo pela Universidade Federal de Viçosa

Joyce, Universidade Federal de Viçosa

Doutora em Engenharia Civil pela Universidade Federal de Santa Catarina.

References

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR 15.220-2: Desempenho térmico de edificações Parte 2: Métodos de cálculo da transmitância térmica, da capacidade térmica, do atraso térmico e do fator solar de elementos e componentes de edificações. Rio de Janeiro, 2005.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR 15.220-3: Zoneamento bioclimático brasileiro e diretrizes construtivas para habitações unifamiliares de interesse social. Rio de Janeiro, 2005.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS NORMA MERCOSUL. ABNT NM 294: Vidro Float. Brasil, Argentina, Uruguai e Paraguai, 2004.

CLARKE, J.; HENSEN, J. Integrated building performance simulation: Progress, prospects and requirements. Building and Environment, v. 91, p. 294–306, 2015. DOI: 10.1016/j.buildenv.2015.04.002.

DE WILDE, P. Building Performance Analysis. Oxford: John Wiley & Sons Ltd, 2018. DOI: 10.1002/9781119341901.

GUIMARÃES, Í. B. Análises de incertezas e sensibilidade de arquivos climáticos e seus impactos em simulações computacionais termo energéticas. 2016. 95 f. Dissertation (MPhil) - Programa de Pós-Graduação em Arquitetura e Urbanismo, Universidade Federal de Viçosa, Viçosa, 2016.

HUERTO-CARDENAS, H.; LEONFORTE, F.; ASTE, N.; DEL PERO, C.; EVOLA, G.; CONSTANZO, V.; LUCCHI, E. Validation of dynamic hygrothermal Simulation models for historical buildings: State of the art, research challenges and recommendations. Building and Environment, v. 180, p. 107081, 2021. DOI: 10.1016/j.buildenv.2020.107081.

MARTÍNEZ-MARINO, S.; EGUÍA-OLLER, P.; GRANADA-ÁLVAREZ, E.; ERKOREKA-GONZÁLEZ, A. Simulation and validation of indoor temperatures and relative humidity in multi-zone buildings under occupancy conditions using multi-objective calibration. Building and Environment, v. 200, 2021. DOI: 10.1016/j.buildenv.2021.107973.

OBERKAMPF, W.; ROY, C. Verification and Validation in Scientific Computing. Cambridge: Cambridge University Press, 2010.

O’ DONOVAN, A.; O’ SULLIVAN, P.; MURPHY, M. Predicting air temperatures in a naturally ventilated nearly zero energy building: Calibration, validation, analysis and approaches. Applied Energy, v. 250, p. 991–1010, 2019. DOI: 10.1016/j.apenergy.2019.04.082.

RAJČIĆ, V.; SKENDER, A.; DAMJANOVIĆ, D. An innovative methodology of assessing the climate change impact on cultural heritage. International Journal of Architectural Heritage, v. 12, p.21-35, 2018. DOI: 10.1080/15583058.2017.1354094.

ROYAPOOR, M.; ROSKILLY, T. Building model calibration using energy and environmental data. Energy and Buildings, v. 94, p. 109–120, 2015. DOI: 10.1016/j.enbuild.2015.02.050.

WEBER, F.; MELO, A.; MANINOSKI, D.; GUTHS, S.; LAMBERTS, R. Desenvolvimento de um modelo equivalente de avaliação de propriedades térmicas para a elaboração de uma biblioteca de componentes construtivos brasileiros para o uso no programa EnergyPlus. 2017. p. 52.

WESTPHAL, F. Análise de incertezas e de sensibilidade aplicadas à simulação de desempenho energético de edificações comerciais. 2007. Tese de Doutorado - Programa de Pós-Graduação em Engenharia Civil, Universidade Federal de Santa Catarina, Florianópolis, 2007.

Published

2022-11-07

How to Cite

LUCARELLI, Caio de Carvalho; OLIVEIRA, Matheus Menezes; CARLO, Joyce Correna. Thermal calibration of an existing institutional building. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 19., 2022. Anais [...]. Porto Alegre: ANTAC, 2022. p. 1–11. DOI: 10.46421/entac.v19i1.1961. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/1961. Acesso em: 22 nov. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Most read articles by the same author(s)

Similar Articles

<< < 21 22 23 24 25 26 27 28 29 30 > >> 

You may also start an advanced similarity search for this article.