ANÁLISE DO DESEMPENHO TÉRMICO DE ELEMENTOS VAZADOS COMO SEGUNDA PELE EM AMBIENTE DE ESCRITÓRIO

Authors

  • Gabriela Bolssoni Universidade Federal do Espírito Santo (UFES)
  • Andréa Laranja Universidade Federal do Espírito Santo (UFES)

DOI:

https://doi.org/10.46421/entac.v18i.741

Keywords:

Thermal Performance, Perforated Solar Screen, Computacional Simulation

Abstract

This research aimed to evaluate the influence of different parameters on the thermal performance of the perforated solar screen for an office environment in a humid tropical climate. In the methodology, the modeling was performed with Rhinoceros3D + Grasshopper applications and computer simulations using the DIVA-for-Rhino plug-in. Three models of perforated solar screen for the West orientation were evaluated. For the evaluations, the same percentage of opening area on the facade was maintained, but the following parameters were varied: thickness of the perforated solar screen, insolation angles (α and β), quantity and dimension of the holes of the evaluated models. In the thermal performance evaluations, we try to understand which of the perforated solar screens has the greatest capacity to reduce the admitted solar radiation. As main results, it is observed that all the evaluated models contributed to the reduction of the admitted radiation. In addition, the perforated solar screen showed more efficient performance in the afternoon, that is, a higher percentage of reduction in the transmitted solar radiation. In addition, it is noted that among the parameters evaluated, the insolation angles are the ones that exert the most significant influence on thermal performance. The model with the lowest insolation angles showed the best performance for all periods evaluated, while the models with the same angles showed similar performance, despite the difference in the other parameters.

References

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS (ABNT). NBR 15220: Desempenho térmico de edificações. Rio de Janeiro: ABNT, 2005.

ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS (ABNT). NBR ISO/CIE 8995-1. Iluminação de ambientes de trabalho – Parte 1: interior. Rio de Janeiro: ABNT, 2013.

BELLIA, L.; FALCO, F.; MINICHIELLO, F. Effects of solar shading devices on energy requirements of standalone office buildings for Italian climates. Applied Thermal Engineering. Eng. 54, 2013.

BOLSSONI, G.; LARANJA, A. A Influência da Refletância dos Elementos Vazados no Desempenho Lumínico. II Congesso Internacional de Arquitetura e Cidade (ARQCIDADE) e X Coletânea ARQURB. Vila Velha, 2019.

BORGSTEIN, E. H.; LAMBERTS, R.; HENSEN, J. L. M. Evaluating Energy Performance in NonDomestic Buildings: a review. Energy and Buildings, v. 128, p. 734-755, 2016.

CARLO, J. Desenvolvimento de metodologia de avaliação da eficiência energética do envoltório de edificações não-residenciais. 2008. Tese (Doutorado) – Programa de PósGraduação em Engenharia Civil, Universidade Federal de Santa Catarina, Florianópolis, 2008.

CARTANA, R.; PEREIRA, F. MAYER, A. Estudo piloto para elementos de controle solar desenvolvidos com modelagem paramétrica e fabricação digital. Ambiente Construído, v.

18, n. 3, p. 67-82, Porto Alegre, 2018.

CHING, F. D. K. Dicionário visual de arquitetura. São Paulo: Martins Fontes, 2010.

CORBELLA, O.; YANNAS, S. Em Busca de uma Arquitetura Sustentável para os Trópicos. Editora Revan, 2003.

FAJKUS, M. Superficial Skins? Super Skins? Shading Structures and Thermal Impact Analysis.

Advanced building skins – energy forum, Bressanone, 2013.

FREEWAN, A. A. Impact of external shading devices on termal and daylighting performance of offices in hot climate regions. Solar Energy, v. 102, p.14-30, 2014.

GOULART, S.; LAMBERTS, R.; FIRMINO, S. Dados climáticos para projeto e avaliação energética para 14 cidades brasileiras. 2ª ed. Florianópolis, 1998.

JONSSON, A.; ROOS, A. Evaluation of Control Strategies For Different Smart Window Combinations Using Computer Simulations. Solar Energy, v. 84, n. 1, p. 1-9, 2010.

LAMBERTS, R.; DUTRA, L.; PEREIRA, F. O. R. Eficiência energética na arquitetura. 3ª ed. São Paulo, 2014.

LAMBERTS, R.; GHISI, R.; RAMOS, G. Impactos da adequação climática sobre a eficiência energética e o conforto térmico de edifícios de escritórios no Brasil. 49p. Florianópolis: LABEEE, 2006.

LIMA, A. C.; DELPUPO, A. M.; SILVA, B. F. P.; SACRAMENTO, B. F.; MADUREIRA, C. C.; ALVARENGA, H. M.; RAMOS, H. E. A.; SILVA, J. G. F.; SCARPATTI, M. P.; ALMEIDA, P. V. D. A energia solar no Espírito Santo: Tecnologias, Aplicações e Oportunidades. ASPE. Vitória, 2013.

VITÓRIA. Lei n°. 4821, de 30 de dezembro de 1998. Código de Edificações do Município de Vitória. Vitória, 1998. Disponível em: Acesso em: 17 out. 2019.

YOSHINO, H.; HONG, T.; NORD, N. IEA EBC Annex 53: total energy use in buildings, analysis and evaluation methods. Energy and Buildings, v. 152, p. 124-136, mar. 2017.

Published

2020-11-04

How to Cite

BOLSSONI, Gabriela; LARANJA, Andréa. ANÁLISE DO DESEMPENHO TÉRMICO DE ELEMENTOS VAZADOS COMO SEGUNDA PELE EM AMBIENTE DE ESCRITÓRIO. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.741. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/741. Acesso em: 23 nov. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Similar Articles

<< < 13 14 15 16 17 18 19 20 21 22 > >> 

You may also start an advanced similarity search for this article.