DESEMPENHO LUMINOSO DE SHED INTEGRADO A PRATELEIRA DE LUZ EM AMBIENTE DE CIRCULAÇÃO
DOI:
https://doi.org/10.46421/entac.v18i.753Keywords:
Zenith opening, Natural lighting, Light shelf, Computer simulationAbstract
Zenith openings in a humid climate contribute to the reduction of expenses with artificial lighting, which can, however, cause excesses in natural lighting. On the other hand, shading devices are good strategies for controlling this luminosity. A research aims to analyze the performance of the opening of the zenith shed integrated to the light shelf in the circulation environment in Vitória-ES. The methodology involves simulations with the software TropLux 8 and Dialux, according to CIE standards, Sky 3 (sky), Sky 7 (cloudy sky) and Sky 12 (clear). The simulated environment is about circulation, with the opening of the shed integrated with the light shelf in the North, South, East and West orientations. The luminaires were analyzed in the ranges of UDIs (Useful Daylight Illuminances) and Autonomy of natural light. It should be noted that, for all the orientations and monitoring analyzed, or a dam integrated or not on the light shelf, it allows 100% autonomy of natural light between 8 am and 4 pm. The results of the IDUs show that the light shelf is just as relevant when oriented to the North in Skies 7 and 12. As the zenith openings provide energy savings with artificial lighting, it is possible to obtain about 350 kWh per year.
References
______. NBR 15215-4: Iluminação natural – Parte 4: verificação experimental das condições de iluminação interna de edificações – Método de medição. Rio de Janeiro: ABNT, 2005c ______. NBR CIE 8995-1: Iluminação de ambientes de trabalho – Parte 1: interior. Rio de Janeiro: ABNT, 2013.
ANEEL — AGÊNCIA NACIONAL DE ENERGIA ELÉTRICA. Dados abertos de tarifas. 2019.
Disponível em <https://www.aneel.gov.br/dados/tarifas>. Acesso em: Maio de 2020.
BAKER, N.; FANCHIOTTI, A.; STEEMERS, K. Daylighting in Architecture – A European Reference Book. London: Earthscan Ltd, 2010.
CABÚS, Ricardo. Validação do programa troplux. Encontro Nacional e Encontro Latinoamericano de Conforto no Ambiente Construído. Anais…Alagoas: ENCAC, ELACAC, 2005.
GARROCHO, J. S.; AMORIM, C. D. Luz natural e projeto de arquitetura: estratégias para iluminação zenital em centros de compras. In: Encontro Nacional de Tecnologia no Ambiente Construido, 2004, São Paulo. Anais...São Paulo: ENTAC, 2004.
GUEDES, J. C. d. S. Manual de Tarifação da Energia Elétrica / Programa Nacional de Conservação de Energia Elétrica. Rio de Janeiro: PROCEL EDIFICA, 2011.
LAMBERTS, R.; DUTRA, L.; PEREIRA, F. O. R. Eficiência Energética na Arquitetura. São Paulo, 2014. 366 p.
LARANJA, A. C. Parâmetros urbanos e a disponibilidade de iluminação natural no ambiente interno. Tese de Doutorado. 285p. PPGAU, UFRJ. Rio de Janeiro, 2010.
LI, D. H. W.; LAM, J. C. An investigation of daylighting performance and energy saving in a daylit corridor. Energy and buildings. Volume 35, maio 2003, pag. 365-373LIMA, A. V. P.; LEDER, S. M.; NODA, L. Estudo lumínico em um edifício de escritórios: um estudo de caso em clima quente e úmido. In: Encontro Nacional de Conforto no Ambiente Construído, 14., 2017, Balneário Camboriú. Anais...Balneário Camboriú: ENCAC, 2017.
LU, M.; DU, J. Dynamic Evaluation of Daylight Availability in a Highly-dense Chinese Residencial Area with a Cold Climate. Energy and Buildings. Volume 193, jun. 2019, pag. 139-159.
MAIOLI, R. N. Avaliação da influência do dispositivo prateleira de luz no conforto visual em edificação comercial com entorno obstruído. Dissertação (Mestrado em Engenharia Civil) –Universidade Federal do Espírito Santo, Centro Tecnológico. 2014.
MANGKUTO, Rizki A. Validation of DIALux 4.12 and DIALux evo 4.1 against the Analytical Test Cases of CIE 171:2006. LEUKOS. The journal of the Illuminating Engineering Society of North America. 2016. DOI: 10.1080/15502724.2015.1061438.
MERESI, A. Evaluating daylight performance of light shelves combined with external blinds in south-facing classrooms in Athens, Greece. Energy and Buildings. Volume 116, 2016, p. 190-205.
NABIL, A.; MARDALJEVIC, J. Useful Daylight Illuminances: a replacement for daylight factors.
Science Direct. Energy and Buildings. Volume 38, n. 7, p. 905-913, 2006.
REBÊLO, Marcelle Maria Pais Silva; CARVALHO, Marlise Lila Silva; CABÚS, Ricardo Carvalho.
Análise do desempenho de abertura zenital para a iluminação natural de circulação em edifício administrativo. XIII Encontro Nacional e IX Encontro Latino-americano de Conforto no Ambiente Construído. Anais…ENCAC, ELACAC. 2015.
REINHART, Christoph; WIENOLD, Jan. The daylighting dashboard e A simulation-based design analysis for daylit spaces. Building and Environment. V. 46, 386-396 p., dec. 2011.