A AVALIAÇÃO PÓS-OCUPAÇÃO APLICADA À QUALIDADE AMBIENTAL INTERNA DE ESCRITÓRIO CORPORATIVO

Authors

  • Eduardo Straub POLI-USP
  • Brenda C. C. Leite POLI-USP

DOI:

https://doi.org/10.46421/entac.v18i.885

Keywords:

Internal Environmental Quality, Air Quality, Thermal Comfort, Post-Occupancy Evaluation

Abstract

This article results in the application of the Post-Occupancy Assessment (APO) method in a corporate office to assess air quality and thermal comfort. The research took place in the winter of 2019 and summer of 2020, where guided tours were carried out, questionnaires were applied and measurements of air quality and thermal comfort parameters were carried out to check the compliance with this environment with technical standards and legislation. The Post Occupancy Evaluation methodology proved to be compatible for the analysis of internal environmental quality focused on air quality and thermal comfort as it provides a clear understanding of the parameters analyzed and the perception of satisfaction of the occupants. This research brings CO2 levels just above the limits established by ANVISA and the concentration of particulates below the recommendations of EPA and EU. Regarding thermal comfort, the dissatisfaction rate is higher than that recommended by ASHRAE 55 (2017) for general thermal comfort (summer and winter) and for local thermal discomfort (summer).

References

ANVISA. Resolução – RE/ANVISA nº 9, 2003. 14.

ASHRAE 55. ANSI/ASHRAE Standard 55-2017 - Thermal Environmental Conditions for Human Occupancy. [S.l.]: [s.n.], 2017.

CETESB. Qualidade do Ar. CETESB. Disponivel em: <https://cetesb.sp.gov.br/ar/qualar/>. Acesso em: 18 ago. 2020.

DIN EN ISO 7730:2006-05. Ergonomics of the thermal environment – Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria. DIN EN ISO 7730:2006-05, 2006-05. 59.

EPA. NAAQS Table. EPA. Disponivel em: <https://www.epa.gov/criteria-air-pollutants/naaqstable>. Acesso em: 04 Maio 2020.

HABIBI, S. The promise of BIM for improving building performance. Energy and Buildings, 15 Outubro 2017. 525-548.

IWBI. The WELL Certification Guidebook v2. [S.l.]: [s.n.], 2018.

SOTSEK, N. C.; LEITNER, D. S.; SANTOS, A. D. P. L. A systematic review of Building Performance Evaluation criterias (BPE). Revista ALCONPAT, 30 Dezembro 2018.

THE EUROPEAN PARLIAMENT AND OF THE COUNCIL THE EUROPEAN UNION. DIRECTIVE 2008/50/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL. The European Parliament and of the Council the European Union. [S.l.], p. 34. 2008.

VILLA, S. B.; ORNSTEIN, S. W. (. ). Qualidade ambiental na habitação: Avaliação pósocupação. São Paulo: Oficina de Textos, 2013.

WHO. Air Pollution. World Health Organization. Disponivel em: <http://www.who.int/airpollution/en/>. Acesso em: 10 Setembro 2018.

Published

2020-11-04

How to Cite

STRAUB, Eduardo; LEITE, Brenda C. C. A AVALIAÇÃO PÓS-OCUPAÇÃO APLICADA À QUALIDADE AMBIENTAL INTERNA DE ESCRITÓRIO CORPORATIVO. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.885. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/885. Acesso em: 24 nov. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Most read articles by the same author(s)

Similar Articles

<< < 72 73 74 75 76 77 78 79 80 81 > >> 

You may also start an advanced similarity search for this article.