ANÁLISE DE ILUMINAÇÃO NATURAL EM SALA DE AULA EM VITÓRIA-ES

Authors

  • Yulli R. Mapelli-basilio Universidade Federal do Espírito Santo (UFES)
  • Andréa Laranja Universidade Federal do Espírito Santo (UFES)

DOI:

https://doi.org/10.46421/entac.v18i.743

Keywords:

Natural lighting, School, Computational Simulation

Abstract

Visual comfort in the indoor environment is considered to be very relevant because it is an essential factor in well-being and learning in school environments. Thus, this research aims to analyze the availability of natural lighting in the classroom in Vitória-ES. In the methodology, simulations were made with the TropLux software, for the CIE standard sky typologies: Sky 3 (overcast), Sky 7 (partly cloudy) and Sky 12 (clear), Northeast orientation. Analyzes were made regarding the percentages of IDUs (Useful Daylight Illuminances) and uniformity according to ABNT. As for IDUs, analyzes were made for all days of the year, from 7 am to 5 pm. With regard to uniformity, this was analyzed on the 21st of each month (January to December) at 8:00 am, 10:00 am, 12:00 pm, 2:00 pm and 4:00 pm, as suggested by NBR 15215-4 (ABNT, 2005). The results of the simulations show that, for Céu 7 and Céu 12, 75% of the simulated hours are characterized by satisfactory natural lighting (500 <E <2.000lx). With regard to uniformity, it was in the Skies 7 and 12 at the simulated times of 10 and 12h that the best results were observed, when the existing marquee manages to guarantee shading and reduce glare.

References

______. NBR 15215-4: Iluminação Natural – Parte 4: Verificação experimental das condições de iluminação interna de edificações – Método de medição. Rio de Janeiro: ABNT, 2004.

______. NBR CIE 8995-1: Iluminação de ambientes de trabalho – Parte 1: interior. Rio de Janeiro: ABNT, 2013.

CABÚS, Ricardo. Validação do programa troplux. Anais…Alagoas: ENCAC, ELACAC, 2005.

KOWALTOWSKI, D. C. C. K. 2011. Arquitetura Escolar: O projeto do ambiente de ensino.

São Paulo: oficina de textos. São Paulo. 2011.

LARANJA, A. C. Parâmetros urbanos e a disponibilidade de iluminação natural no ambiente interno. 2010. 285 f. Tese Doutorado. PPGAU, UFRJ, Rio de Janeiro, 2010.

MERESI, A. Evaluating daylight performance of light shelves combined with external blinds in south-facing classrooms in Athens, Greece. Energy and Buildings, v. 116, p.190-205, 2016.

MICHAEL, Aimilios; HERACLEOUS. Assessment of natural lighting performance and visual comfort o educational architecture in Southern Europe: The case of typical educational school premises in Cyprus. Energy and Buildings, 140, p. 443–457. 2017.

NABIL, A.; MARDALJEVIC, J. Useful daylight illuminances: A replacement for daylight factors. Energy and Buildings, London: Elsevier, v.38, p. 1343-1348, 2006.

NASCIMENTO, Gúliti Ricardo Fagundes. A saúde vista com outros olhos: Iluminação Hospitalar. Revista SUSTINERE. V.7, n. 2, p. 401-413, jul-dez. Rio de Janeiro. 2019.

YAO, Qi; CAI,Wenjing; LI, Min; HUC, Zhiguo; XUE, Peng; DAI, Qi. Efficient circadian daylighting: A proposed equation, experimental validation, and the consequentimportance of room surface reflectance. Energy & Buildings, 210 (2020).

Zapata González, L.J; Quiceno Hoyos, A.; Arteaga Botero, M.T. Evaluación lumínica de los ambientes pedagógicos de la Universidad Católica de Manizales, Colombia.

Arquetipo (13), Jul- Dez, p. 157 - 178. 2016.

Published

2020-11-04

How to Cite

MAPELLI-BASILIO, Yulli R.; LARANJA, Andréa. ANÁLISE DE ILUMINAÇÃO NATURAL EM SALA DE AULA EM VITÓRIA-ES. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.743. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/743. Acesso em: 24 nov. 2024.