ILUMINAÇÃO NATURAL EM DIFERENTES GEOMETRIAS DE COZINHA EM VITÓRIA - ES

Authors

  • Daniela Silva Universidade Federal do Espírito Santo,
  • Andréa Laranja Universidade Federal do Espírito Santo

DOI:

https://doi.org/10.46421/entac.v18i.806

Keywords:

Natural lighting, Kitchen geometry, Luminous performance

Abstract

Building legislation indicates standards of measures, areas and minimum dimensions, to be fulfilled on architectural project, which are not a guarantee of light comfort for the user, nor energy performance for the building. This research aimed to analyze the luminous performance of kitchens with different geometries in a humid tropical climate. Four kitchen models were simulated on troplux 8, with the same area, on the 4th and 15th floors representing a multifamily building in Vitória - ES. The simulations took place between 8am and 5pm all the year, in the Southeast and Northeast orientations in a dynamic sky. The analysis used the metrics Useful Daylight Illuminances (UDI), Daylight Autonomy (DA), Average of the illuminances in the solstices, equinoxes and isolux curves. As a conclusion for the DA, no model reached a minimum value of 200 lux. Regarding UDIs percentages, Rectangular Model 1 (MR1) for the Northeast and Southeast, stands out slightly compared to the Long Model (MC). In the average of the Illuminances, a low illuminance value was observed for all kitchen models for the Northeast and Southeast. Regarding the Isolux Curve for the 15th floor, all models obtained the minimum illuminance suggested by the Standard.

References

ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS – ABNT. NBR ISO/CIE 8995-1.

Iluminação de ambientes de trabalho – Parte 1: interior. Rio de Janeiro: ABNT, 2013ABNT ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR 15215-4: iluminação natural: verificação experimental das condições de iluminação interna de edificações: método de medição. Rio de Janeiro, 2005.

ALBUQUERQUE, M. S. C.; AMORIM, C. N. D. Iluminação natural: indicações de profundidadelimite de ambientes para iluminação natural no Regulamento Técnico da Qualidade do Nível de Eficiência Energética de Edifícios Residenciais - RTQ-R. Ambiente Construído, Porto Alegre, v. 12, n. 2, p. 37-57, jun. 2012 .

ALRUBAIH, M. S. et al. Research and Development on Aspects of Daylighting Fundamentals.

Renewable and Sustainable Energy Reviews, v. 21, p. 494-505, 2013.

FONSECA, R., PEREIRA, F., & CLARO, A. (2010). Iluminação natural: a contribuição de suas reflexões no interior do ambiente construído. Pós. Revista Do Programa De Pós-Graduação Em Arquitetura E Urbanismo Da FAUUSP, (28), p.198-217. https://doi.org/10.11606/issn.2317-2762.v0i28p198-217MARDALJEVIC, J. et al. Daylighting Metrics for Residential Buildings. In: SESSION OF THE CIE, 27., 2011, Sun City. Proceedings... Sun City: CIE, 2011.

REINHART, Christoph; WIENOLD, Jan. The daylighting dashboard e A simulation-based design analysis for daylit spaces. Building and Environment, V. 46, 386-396 p., dec. 2011.

VITÓRIA. Lei n°. 4821, de 30 de dezembro de 1998. Código de Edificações do Município de Vitória. Vitória, 1998. Disponível em: <https://leismunicipais.com.br/codigo-de-obras-vitoriaes>. Acesso em: 09 de maio de 2020.

Published

2020-11-04

How to Cite

SILVA, Daniela; LARANJA, Andréa. ILUMINAÇÃO NATURAL EM DIFERENTES GEOMETRIAS DE COZINHA EM VITÓRIA - ES. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.806. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/806. Acesso em: 22 dec. 2024.

Issue

Section

(Inativa) Conforto Ambiental e Eficiência Energética

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.