CONCENTRAÇÃO DE MATERIAL PARTICULADO PROVENIENTE DA FASE DE ATIVIDADES DE TERRAPLENAGEM E FUNDAÇÕES: ESTUDO EM UM CANTEIRO DE OBRAS RESIDENCIAL

Authors

  • Ingrid Priscylla Silva Araújo Universidade Federal da Bahia
  • Dayana Bastos Costa Universidade Federal da Bahia

DOI:

https://doi.org/10.46421/entac.v18i.979

Keywords:

Atmospheric Pollution, Particulate Matter, Environmental Impacts, Construction Sites, Construction

Abstract

Construction generates environmental impact and one of the main impacts is related to air pollution by particulate matter (PM). Current concerns indicate that it is necessary to deal with this challenge of the construction, understanding its influences and implications on air quality. This study investigated the concentration of PM (PM10 and Total Suspended Particles - TSP) from the earthmoving and foundation phase of one construction site, based on field monitoring. The experimental study was conducted at one building construction site over ten working days and more one non-working day for 24 h/day (12h daytime + 12h night time). 12 MiniVols were used to collect the suspended PM, Sticky Pads to collect the settleable particles and a meteorological station. About 132 and 38 samples were obtained for the MP and Sticky Pads, respectively. The results demonstrated that the construction site motivated an increase of the concentration of local levels of the particles, potentiating in greater instance the TSP followed by PM10. It was possible to identify high levels of nuisance caused by settleable particles. This article provides a better understanding of the concentration of PM in construction sites during earthmoving and foundation phase and presents knowledge for real situations from construction.

 

References

AHMED, S.; AROCHO, I. Emission of particulate matters during construction: A comparative study on a Cross Laminated Timber (CLT) and a steel building construction project. Journal of Building Engineering, v. 22, p. 281-294, 2019.

ARAUJO, I.P.S. Metodologia para Avaliação e Redução de Impactos Ambientais causados pela emissão de material particulado de canteiros de obras habitacionais com foco no impacto à vizinhança da obra. Dissertação de Mestrado. Escola Politécnica, Universidade Federal da Bahia, Salvador, 2014.

ARAÚJO, I.P.S.; COSTA, D.B.; MORAES, R.J.B. Identification and Characterization of Particulate Matter Concentrations at Construction Jobsites. Sustainability (Basel), v.6, p. 7666-7688, 2014.

AZARMI, F.; KUMAR, P.; MARSH, D.; FULLER, G. Assessment of the long-term impacts of PM10 and PM2.5 particles from construction works on surrounding areas. Environ. Sci.: Processes Impacts, v.18, p. 208, 2016.

CHERIYAN, D.; CHOI, J. A review of research on particulate matter pollution in the construction industry. Journal of Cleaner Production, v. 254, 120077, 2020.

CHIANG, Y.C.; KUO, C.C. Characteristics of suspended particulate matter emitted from various stages of construction works. Journal of Aerosol Science, v. 35, p. S995-S996, 2004.

CONAMA CONSELHO NACIONAL DO MEIO AMBIENTE. Resolução Conama nº491. 2018.

Disponível em: . Acesso em: 05 abr. 2020.

FELICIANO M.; GONÇALVES A.; GOMES P.; CARDOSO A.; ARAÚJO R. Partículas em Suspensão na Praça Camões (Bragança), durante a Construção do Parque de Estacionamento. 8ª Conferência Nacional de Ambiente. Lisboa, 2004. Disponível em: <http://hdl.handle.net/10198/6473>. Acesso em: 07 abr. 2020.

HANBY, I. Airborne dust monitoring equipment. 2014. Disponível em:<http://www.hanby.co.uk/CAL%20&%20USE%20SPR.htm >. Acesso em: 22 abr. 2020.

HEAL, M.R.; KUMAR, P.; HARRISON, R.M. Particles, air quality, policy and health. Chemical Society Reviews, v. 41, p. 6606-6630, 2012.

LI, H.; FANG, C.H.; SHI, W.; GURUSAMY, S.; LI, S.; KRISHNAN, M.N.; GEORGE, S. Size and site dependent biological hazard potential of particulate matters collected from different heights at the vicinity of a building construction. Toxicology Letters, v.238, p. 20–29, 2015.

MELO, M. M. DE. Correlação entre percepção do incômodo e exposição ao material particulado presente na atmosfera e sedimentado. Tese (Doutorado em Engenharia Ambiental) – Universidade Federal do Espírito Santo, Espírito Santo. 2015.

MORAES, R.J.B. Avaliação da emissão do material particulado proveniente de canteiros de obras habitacionais na fase de estrutura e alvenaria. Dissertação de Mestrado. Escola Politécnica, Universidade Federal da Bahia, Salvador, 2015.

MORAES, R. J. B.; COSTA, D. B.; ARAUJO, I. P. S. Particulate matter concentration from construction sites: concrete and masonry works. Journal of Environmental Engineering, v. 1,05016004, 2016.

RESENDE, F.; CARDOSO, F.F.; COSTA, D.B.; MELO, A.; ARAÚJO, I.P.S.; MORAES, R.J.B.; PORFIRO, A. Metodologia para medição da concentração de material particulado em canteiros de obra. Proc. 8° Simpósio Brasileiro de Gestão e Economia da Construção. Salvador, Brasil. 2013.

WHO WORLD HEALTH ORGANIZATION. Ambient air pollution: a global assessment of exposure and burden of disease. ISBN: 9789241511353, 2016. Disponível em: <https://www.OMS.int/airpollution/data/en/>. Acesso em: 22 abr. 2020.

Published

2020-11-04

How to Cite

ARAÚJO, Ingrid Priscylla Silva; COSTA, Dayana Bastos. CONCENTRAÇÃO DE MATERIAL PARTICULADO PROVENIENTE DA FASE DE ATIVIDADES DE TERRAPLENAGEM E FUNDAÇÕES: ESTUDO EM UM CANTEIRO DE OBRAS RESIDENCIAL. In: NATIONAL MEETING OF BUILT ENVIRONMENT TECHNOLOGY, 18., 2020. Anais [...]. Porto Alegre: ANTAC, 2020. p. 1–8. DOI: 10.46421/entac.v18i.979. Disponível em: https://eventos.antac.org.br/index.php/entac/article/view/979. Acesso em: 24 nov. 2024.

Most read articles by the same author(s)

1 2 > >> 

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.